Provides Supplemental Info Re 971223 Lar,Revising TS Definition of Core Alteration,Relocating TS 3/4.9.5 & Adding TS 3.0.6 & Associated Bases
ML20249A080
Person / Time
Site: Davis Besse 
Issue date: 06/11/1998
From: Jeffery Wood
CENTERIOR ENERGY
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
2543, NUDOCS 9806160034
Download: ML20249A080 (2)


Text

- - _ _ _ _.. _ _ _ _ -

.n.

E="-

n9" '

Davis-Besse Nuclear P6wer Station EE 5501 North State Route 2 Cak Harbor. Ohio 43449-9760 m

John K. w6cd.

419-249-2300 Vee President -Nuclear -

Far 419-3218337

Docket humber 50-346 License Number NPF-3 Serial Number 2543 June 11. 1998

. United States Nuclear Regulatory Commission

' Document Control Desk Washington, DC 20555-0001

Subject:

SupplementalInformation Regarding License Amendment Application to Revise the Technical Specification Definition of Core Alteration; Relocate

. TS 3/4.9.5 - Refueling Operations - Communications and its Bases to the Technical Requirements Manual; and add TS 3.0.6 and Associated Bases

. Regarding the Return to Service of Inoperable TS Equipment (License Amendment Request No. 97-0002)

Ladies and Gentlemen:

(g The purpose of this letter is to provide supplemental information for a pending license k

amendment application regarding the Davis-Besse Nuclear Power Station (DBNPS), Unit Number 1 Operating License Number NPF-3. The subject application, License Amendment Request (LAR) Number 97-0002, dated December 23,1997 (Toledo Edison

.jf Serial Number 2462), involves a proposed change to the Technical Specification (TS)

)

\\'

Definition of Core Alteration; relocation TS 3/4.9.5 - Refueling Operations -

j Communications and its Bases to the Updated Safety Analysis Report (USAR) Technical Requirements Manual (TRM); and the addition of TS 3.0.6 and associated Bases regarding i

1 the return to service of inoperable TS equipment.

- This supplemental information is provided in response to a verbal request from the NRC Staff to clarify several issues, as described in further detail below, regarding t.he portion of the application relative to the proposed relocation 'of TS 3/4.9.5 Refueling Operations -

Communications and its. Bases to the USAR TRM.

D k

.-_ _ O

.P -

8

'g Docket Number 50-346 License Number NPF Serial Number 2543

. Page 2

' Following NRC approval and issuance of the proposed license amendment, the DBNPS will" add the appropriately reformatted TS 3/4.9.5 and its Bases into the USAR TRM concurrently with its removal from the TS. This action will be accomplished within the amendment implementation period specified by the NRC in the license amendment.

L Perforrning these actions concunently will provide assurance that the requirements for refueling operations communications will remain in effect continuously.

Relative to proposals to relocate TS requirements to other licensee-controlled documents, the NRC's " Final Policy Statement on TS Improvements for Nuclear Power Reactors",

s (58 FR 39132 dated July 22,1993) provides guidance that the license amendment request include a statement that the proposed changes "have been approved by a multidisciplinary group of responsible, technical supervisory personnel, including onsite operations

personnel." The DBNPS confirms that all license amendment applications, including the

.- subject license amendment application, are reviewed by the Station Review Board prior to submittal to the NRC. The composition of the Station Review Board is described in TS Section 6.5.1.2, Administrative Controls - Station Review Board (SRB) - Composition.

The SRB review meets the above-mentioned guidance.

Should you have any questions or require additional information, please contact

. Mr. James L. Freels, Manager - Regulatory Affairs, at (419) 321-8466.

. Very truly yours, MKUlaj cc:

A. B. Beach, Regional Administrator, NRC Region III A. G. Hansen, DB 1 NRC/NRR Project Manager

. S. J. Campbell,' DD-1 NRC Senior Resident Inspector J. R. Williams, Chief of Staff, Ohio Emergency Management Agency, State of Ohio (NRC Liaison)

Utility Radiological Safety Board hhh p

~