ML20248L563

From kanterella
Jump to navigation Jump to search
Forwards Listings of Sealed Source & Device Pending Cases as of 980312 Including Actions Submitted as Technical Assistance Request from Headquarters or Regions & List of Actions Filed by Vendor & Regions
ML20248L563
Person / Time
Issue date: 03/12/1998
From: Camper L
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To: Caniano R, Dan Collins, Pangburn G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I), NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II), NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
SSD, NUDOCS 9803230203
Download: ML20248L563 (26)


Text

MEMORANDUM TO: G:crge P ngbum, D:puty Dir:ctor March 12, 1998 Division cf Nucle r Mat;rirls S:fity, RI Douglas M. Collins, Director Division of Nuclear Materials Safety, Rll Roy J. Caniano, Deputy Director Division of Nuclear Materials Safety, Rlli D. Blair Spitzberg, Chief Nuclear Materials Licensing Branch, RIV Frank Wenslawski, Chief Walnut Creek Field Office, RIV FROM:

Larry W. Camper, Chief [ orig, signed by S. Baggett, for]

Material Safety Branch Division of Industrial and Medical Nuclear Safety, NMSS

SUBJECT:

STATUS OF SEALED SOURCE AND DEVICE REQUEST FOR REGISTRATION Attached are listings of the sealed source and device pending cases as of March 12, 1998. Attachment 1 contains actions that were submitted as a technical assistance request i

from headquarters or the regions, and attachment 2 lists all actions inat have been filed directly by the vendor and regions, for product evaluation and registration.

)

Attachments: As stated

Contact:

KimBerly Randall, NMSS (301) 415-8140.

4 DISTRIBUTION: w/ enclosures VCampbell, RIV BJones, LFDCB w/o encis.

JKinneman, RI SMoore, OB NMSS r/f IMNS r/f JMadera, Rlll CHosey, Ril MPhillips, Rlli FCombs JPotter, Rll MShanbaky, Rl SKimberly, LFDCB DCool i

JJohansen,RI CFrazier, Rlll Blough, RI BPrange,RIV WCFO GShear, Rlll FCostello, RI MMeenan, Rill LJacobs-Baynard, PMDA SVillar, RI TDecker, Rll NEO2-SSD-7 g CCain, RIV CPederson, Rill Chamberlain, RIV DOCUMENT NAME: G:\\ Regions. Reg T e

.h,.. e.py.: tw. 4..

nt, inae.i. in ih. box: c = Co/without tt chm.nt/.ncio.ur.

"E" = Copy with.tt. chm.nt/enclosur.

  • N* = No copy

[ OFFICE MSB g l

MSB /

lC MSBE,0 ld l

l l

llNAME KRanMil SBap(ett LCam'per

[DATE 3//2198 3]//98 3/1/98 OFFICIAL RECORD COPY 9803230203 980312 1M/11:m1 llH,WHlllifMllg)

PDR RC M

SSD PDR

  • '
  • i

, H.

ATTACHMENT 1 Pending Sealed Source & Device Actions Tied to Licensing Actions By Region for the period 1/1/01 to 3/12/98 Actions recorded as of Thursday, March 12,1998 HQ s case (s) Assignea to Heviewer(s) iotaung s Action (s) control Assign. s Number Actions Reviewer Company Model Numbers 0

97-55 Smith Walter Kidde Port. Equip.

SMD1, 0805, 0905, 0906, 0908, 0914,0916, 1

0918 0

97 57 Lee Edwards Systems Tech (EST) 305 Series,235 Seres 1

0 98-32 Kirkwood Kidde Safety CPD 705X SMOKE DETECTOR 1

021700 97-62 Lee Universal Security Inst.

Series SS-750 1

021896 97-79 Kirkwood American Sensors SA4,300, Micro 300,330,350 Series 1

0219CO 97-34 Compton PSI Powertronic Systems, Drift Tube Assembly 1

021941 98-U1 Lubinski Dynalec Corporation IC/SF (3499),3464,3466 1

I 021941 98-03 Lubinski Win 9 Corporation IC/SF (3499) 3464,3466 l

1 l

1 Sealed Source Safety Section j

l

1 Pending Sealed Source & Device Actions Tied to Licensing Actions By Region for the period 1/1/01 to 3/12/98 Actions recorded as of Thursday, March 12,1998 R1 z case (S) Assigned to Meviewer(S) Iotaling Z ACitOn(S) control Assign. #

i Number Actions Reviewer Company Model Numbers 1

124672 97-48 Compton Allegheny University Hosp.

SrO.A53 1

125162 97-82 Lee Intergrated Ind. Systems RSS-06 1

l I

I 1

l 1

Sealed Source Safety Section

D Pending Sealed Source & Device Actions Tied to Licensing Actions By Region for the period 1/1/01 to 3/12/98 Actions recorded as of Thursday, March 12,1998 SSSS 51 vase (s) AS$lgned to Neviewer(s) iOtaling WZ Action (S) control Assign. s Number Actions Reviewer Company Model Numbers96-107 Jankovich Theratronics 1000E Seres 1

0 95 47 Lee Sony Chemical Corp.

WG8 1

0 96-35 Compton DMW Geophysical EUD1, TUD1 1

0 96 36 Compton Stock Equipment Company 026752 1

0 96-37 Burgess American Airlines Rigid guide tube /collimater 1

0 96-38 Burgess TWA Rigd guide tube 1

0 96-44 Compton Mirtone Industnes, Inc.

73470u 1

0 96-85 Compton Agfa Corporation BKG 40823-01 1

0 96-87 Burgess Dept. of Agriculture Husman irradiator 1

0 96-93 Jankovich Gray

  • Star, Inc, Gray
  • Star 1

0 96-102 Smith IRIS Control Cable Housing l

1 Sealed Source Safety Section

1 Pending Sealed Source & Device Actions Tied to Licensing Actions l

By Region for the period 1/1/01 to 3/12/98 Actions recorded as of Thursday, March 12,1998 SSSS 51 Case (s) Assignea to Heviewer(s) Iotaling 92 Action (s).

)

control Assign. #

4 Number Actions Reviewer Company Model Numbers l

0 96-108 Jankovich Theratronics 780 Senes 1

0 97-07 Jankovich Nuclear Research Corp.

SH-301, SH-302, SH-352

)

1 0

97 16 Compton Capintec, Inc.

CR-168E.154E,178E,164 E,165E, 486E 2

0 97 21 Smith lon Track Instruments Models 27,58,62,70, & 75 1

0 97-23 Compton FEMA CDV-757 l

1 0

97-24 Compton FEMA CDV-778, 782, 784, 786 1

0 97-25 Compton FEMA CDV 794 Model No. 2 j

1 l

0 97-26 Compton FEMA CDV-797 1

0 97-27 Compton FEMA CDV-791, CDV-792 1

0 97-28 Compton FEMA CDV-790 Model i 1

0 97 30 Compton GE Medical Systems Model 2180506 l

1 l

l 2

Sealed Source Safety Section 1

Pending Sealed Source & Device Actions Tied to Licensing Actions By Region for the period 1/1/01 to 3/12/98 Actions recorded as of Thursday, March 12,1998 SSSS 51 case (s) Assigned to Heviewer(s) iotaling WZ Action (s) control Assign. #

Number Actions Reviewer Company Model Numbers 0

97-37 Broaddus Apgee Corporation LB 300 IPD/L 1

0 97-38 Broaddus Apgee Corporation Model LB AS 1

i 0

97-39 Broaddus Apgee Corporation Model LB 330 1

0 97-41 Compton ES industries D42 1

0 97-42 Jankovich Apgee Corporation LB 379 1

1 0

97-43 Jankovich Apgee Corporation LB 300 L/LP l

0 97-44 Jankovich Apgee Corporation LB 300 IRL 1

0 97-45 Jankovich Apgee Corporation LB 300 ML/MLT 1

0 97-46 Jankovich Apgee Corporation LB 300 MUMLT l

1 0

97 47 Compton Stocker & Yale P650 1

0 97-59 Lee Stocker & Yale 80800, 490,184-B,184-B1, 5903, 5904, 5905 1

t 1

Sealed Source Safety Section

l Pending Sealed Source & Device Actions Tied to Licensing Actions By Region for the period 1/1/01 to 3/12/98 Actions recorded aS of Thursday, March 12,1998 l

SSSS 51 casels) Assignea to Keviewer(s) iotaling W Action (s) control Assign. #

Number Actions Reviewer Company Model Numbers 0

9740 Lee TSIincorporated Models 3012,3054,3013,3078 1

0 9741 Lee Lockheed Martin 5310,5310-1,5310-3, 5310-5 1

0 9743 BurDess Perkin Elmer Voyager 1

0 9744 Jankovich Motorex, Inc.

HEPS, LEPS, DOPS, SAPS, SSPS, SLPS 1

0 9746 Lee Motorex, Inc.

Courier 20 1

0 97-67 Compton EAD Metallurgical, Inc.

AMX-1100 FOIL 1

0 9748 Compton EAD Metallurgical, Inc.

AMX-11N1, AMX-11N2 1

0 9749 Compton Merrick - Scale Merrick Scale - NCPM 1

0 97-70 Compton Parkwell Lab, Inc.

PL-AMBE, AM, AC, PL 200 5

0 97 71 Lee Litton Medical Products Toshiba RCR-120 2

0 97-75 Jankovich MDS Nordion C-337A l

1 Sealed Source Safety Section

Pending Sealed Source & Device Actions Tied to Licensing Actions By Region for the period 1/1/01 to 3/12/98 Actions recorded aS of Thursday, March 12,1998 SSSS 61 case (s) Assignea to Heviewer(s) iotaling wz Action (s) control Assign. #

Number Actions Reviewer Company Model Numbers 0

97-76 Lee Apgee Corporation LB BW 1

0 97-77 Lee Apgee Corporation LB 375 1

0 97-78 Lee Dept. of tne Army ACADA 1

0 97 80 Lee RSNP RSNP-AU 1

0 97 81 Lee RSNP RSNP-IR, RSNP-2 1

0 97-83 Lee Nuclear Research Corp.

SH-300 Seres, LS-101 2

0 98-02 Lee Seaman Nuclear Corp.

C-100, C-200 1

0 98-05 Lee Seaman Nuclear Corp.

C-300 1

0 98-06 Lee Mallinkrodt 5540,5541,5542, Models 006-012, Elutek 6724 5

0 98-08 Jankovich MDS Nordion C-188 1

0 98-09 Jankovich MDS Nordion Gammacell1000/3000 1

1 Sealed Source Safety Section

Pending Sealed Source & Device Actions Tied to Licensing Actions By Region for the period 1/1/01 to 3/12/98 Actions recorded as of Thursday, March 12,1998 SSSS 61 GaSe(s) Assignod to Keviewer(s) IOtaling WZ Action (s) control Assign. 5 Number Actions Reviewer Company Model Numbers 0

98-10 Lee Eberkne Instrument Corp.

8150-120-CS 1

0 98-11 Lee Eberline Instrument Corp.

8150-xxxAB 1

0 98-12 Lee Eberline Instrument Corp.

1000 1

0 98-13 Lee Ebertine instrument Corp.64-764 1

0 98-14 Lee Eberkne instrument Corp.

1000 B 1

0 98-15 Lee Eberkne instrument Corp.

SCS 1001-1008 1

0 98-16 Lee Eberline instrument Corp.

DNS-5 0

98-17 Lee Ebertine Instrument Corp.

DNS-5A 1

0 98-18 Lee Ebertine instrument Corp.

S94-1, S94-2. S944 1

0 98-19 Lee Ebertine instrument Corp.

DNS-7, DNS-10, DNS-17 l

O 98-20 Lee Eberline Instrument Corp.

DNS-1, DNS-16, DNS-21 1

l 1

Sealed Source Safety Section l

l l

L__-_____-___--_--___.----..___

Pending Sealed Source & Device Actions Tied to Licensing Actions By Region for the period 1/1/01 to 3/12/98 Actions recorded as of Thursday, March 12,1998 SSSS 81 case (s) Assignea to Meviewer(s) iotaling WZ AClion(s) control Assign. #

Number Actions Reviewer Company Model Numbers 0

98-21 Lee TMA/Eberkne CS-1, C5-3, CS-10. CS-12, CS-15, CS-16 1

0 98-22 Lee TMA/Ebertine CS-7A, CS-7B 1

0 98-23 Lee TMA/Eberiine DNS-26 1

0 98-24 Lee TMA/Ebertine DNS-8, DNS-9 1

l 0

98-25 Lee TMA/Ebertine DNS-6 l

I I

l 0

98-26 Lee TMA/Eberiine DNS-4, DNS-11, S-1 1

0 98-27 Lee TMA/Eberline DNS-2, DNS-14 1

0 98-28 Jankovich The Source, Inc.

TS-241-Alpha 1

0 98-29 Jankovich The Source, Inc.

TS-241 1

0 98-31 Jankovich MDS Nordion C-188 1

0 98-33 Unassigned Dept. of the Air Force 1

l 1

Sealed Source Safety Section

Pending Sealed Source & Device Actions Tied to Licensing Actions By Region for the period 1/1/01 to 3/12/98 Actions recorded as of Thursday, March 12,1998 SSSS 51 vase (s) Assigned 10 Meviewer(S) IOtaling WZ Action (s) control Assign. s Number Actions Reviewer Company Model Numbers 0

98-34 Unassigned Ohmart Corporation SHRH-A 1

0 98-35 Jankovich MDS Nordion Gammacell 40 1

0 98-36 Unassigned Advanced Gauging AGT 400 1

0 98-37 Broaddus EG&G Berthold LB7400 Series 1

)

l l

l l

l 1

Sealed Source Safety Section 4

)

Pending Sealed Source & Device Actions Tied to Licensing Actions

{

By Region for the period 1/1/01 to 3/12/98 Actions recorded as of Thursday, March 12,1998 SSSS 51 case (S) Assigned to Meviewer(S) 1Otaling WZ Action (S) control Assign. s Number Actions Reviewer Company Model Numbers Total Open Case (s) for All Regions is 91 Totaling 102 Action (s) 1 Sealed Source Safety Section l

ATTACHMENT 2 Pending Sealed Source & Device Actions Actions received dudng the period 1/1/01 to 3/12/98 For actions recorded as of Thursday, March 12,1998 Date Assign. #

Received Reviewer Actions Company Model Numbers Status 5/19/95 95-47 Lee 1 Sony Chemical Corp.

WG8 new custom device to fees 5/19/95. fee OK 5/24/95.

Def. Itr sent on 7/15/96 Resp. rcvd on 12/6/96.

Def. mtg on 10/9/97.

Void ttr sent on 12/4/97.

Ltr dated 12/22/97 frm apphcant requesting an extension.

Case has been reassigned frm D.Broaddus to S. Lee on 1/12/98.

4/24/96 96-35 Compton 1 DMW Geophysical EUD1, TUD1 N/A from fees Action has been transferred to E. Compton.

4/26/96 96-36 Compton 1 Stock Equipment D26752 To fees on 4/29/96.

Company Rtmed frm fees on 5/3/96.

Action has been transferred to E. Compton.

4/26/96 96-38 Burgess 1 TWA Rigid guide tube To fees on 5,2/96 Rtmed frm fees on 5/21/96.

Additionalinf. rcvd on 8/26/96.

Working on action wiconjuction w/96-04.

96-04 transfered to MA on 3/97.

Def. ltr sent on 10/30/97.

30-day extension was given till 1/5/98.

Def. resp revd on 1/6/98.

1 Sealed Source Safety Section

l Pending Sealed Source & Device Actions Actions received during the period 1/1/01 to 3/12/98 For actions recorded as of Thursday, March 12,1998 pate Assign. s Received Reviewer Actions Company Model Numbers Status 4/30/96 96 37 Bergess 1 American Airlines Rigid guide tube /colkmater To fees on 5/1/96 New Fee ruhng Rtrned frm fees on 5/28/96.

Additional inf. revd on 1

8/26/96.

Working on action w/conjuction w/96-04 96-04 transfered to MA on

'i 3/97.

Def. Itr sent on 10/30/97.

Def. resp. rcvd on 11/18/97.

Def. call & Ltr sent on 11/18/97.

Def. reso revd on 1/6/98.

5/21/96 96-44 Compton 1 Mirtone industnes, Inc.

73470u To Fees on 6/6/96 Rtmed frm fees on 7/26/96.

Action has been transferred to E. Compton on 4/29/97.

8/19/96 96-85 Compton 1 Agfa Corporaton BKG 40823-01 To Fees on 8/20/96.

Rtmed frm fees on 8/22/96.

Action is with Fred Combs 4/29/97.

Action has been transferred to E. Compton. -

9/25/96 96-87 Burgess 1 Dept. of Agriculture Husman irradiator To fees on 9/30/96.

Rtmed frm fees on 10/4/96.

j Def. call on 9/25/96.

i 30 day void ltr sent on 1/17/97.

Resp. revd on 3/5/97.

l r

1 2

Sealed Source Safety Section

\\..

Pending Sealed Source & Device Actions Actions received during the period 1/1/01 to 3/12/98 l

For actions recorded as of Thursday, March 12,1998 Date Assign. lp Received Reviewer Actions Company Model Numbers Status 10/2/96 96-93 Jankovich 1 Gray

  • Star, Inc, Gray
  • Star To Fees on 10/11/96.

Rtrned frm fees on 11/5/96.

AddRional information revd on 11/29/96.

Rtrned back to Fees on 12/23/96.

Rtrned frm Fees on 12/30/96.

Def. Itr sent on 1/27/97.

Def. Itr revd on 4/7/97.

Meeting w/ Gray Star and SFPO on 5/7/97.

Case has been transferred to J. Jankovich on 2/4/98.

10/11/96 96-102 Sr.aith 1 IRIS Control Cable Housing To Fees on 10/15/96.

Rtmed frm fees on 11/5/96.

Def. call and Ltr sent on 1/9/97.

Partial resp. revd on 2/19/97.

30 day ltr sent on 3/24/97.

Resp. revd on 03/28/97.

Def. call on 5/30/97.

Def. resp. revd on 8/12/97.

Def. call on 11/10/97.

l 3

Sealed Source Safety Section l

l l

i Pending Sealed Source & Device Actions Actions received during the period 1/1/01 to 3/12/98 For actions recorded aS of ThurS@y, March 12,1998 Date Assign. 5

~7' Received Reviewer Actions Company l Model Numbers Status 11/14/96 96-107 Jankovich 1 Therstronics 1000E Series To Fees on 11/14/96.

Rtmed frm fees on 11/29/96.

Action has been transferred to J. Jankovich on 10/29/97.

Def. call on 12/3/97.

Def. Itr sent on 12/5/97.

Def. resp. revd on 1/5/98.

11/14/96 96-108 Jankovich 1 Theratronics 780 Series To Fees on 11/18/96.

Rtmed frm fees on 11/29/96.

Action has been transferred to J. Jankovich on 10/29/97.

Def. call on 12/3/97.

Def. ltr sent on 12/5/97.

j Def. resp. revd on 1/5/98.

2/25/97 97-07 Jankovich i Nuclear Research SH-301, SH-302, SH-352 To fees on 2/26/97.

Corp.

Rtmed frm fees on 3/3,97.

Action has been reassigned to J. Jankovich on 10/17/97.

Def. ltr sent on 10/31/97.

Lir dated 1/5/98 frm applicant requesting extension. Resp.

rcvd on 2/12/98.

l 3/18/97 97-16 Compton 2 Capintec, Inc.

CR-168E,154E,178E.164E, To Fees on 3/21/97.

165E,486E Rtmed frm fees on 4/2/97.

4 Sealed Source Safety Section

i Pending Sealed Source & Device Actions Actions received during the period 1/1/01 to 3/12/98 For actions recorded as of Thursday, March 12,1998 l

Date Assign. #

Received Reviewer Actions Company Model Numbers Status 3/20/97 97-21 Smith 1 lon Track Instrumerits Models 27,58,62,70, & 75 To Fees on 3/26/97.

See also 94-09 Rtmed frm fees on 4/2/97.

Def. Itr sent on 5/7/97 Partial def resp revd on 5/14/97.

Def. call on 11/13,97.

Revd def. resp on 11/17/97.

3/28/97 97-30 Compton 1 GE Medical Systems Model 2180500 To fees on 4/3/97 Rtmed frm fees on 4/8/97.

Def ftr sent on 2/23/98.

4/1/97 97-23 Compton 1 FEMA CDV-757 To Fees on 4/2/97.

Rtmed frm fees on 4/8/97.

4/1/97 97-24 Compton 1 FEMA CDV-778, 782, 784, 786 To Fees on 4/2/97.

Rtmed frm fees on 4/8/97.

4/1/97 97-25 Compton 1 FEMA CDV-794 Model No. 2 To Fees on 4/2/97.

Rtmed frm fees on 4/8/97.

4/1/97 97-26 Compton 1 FEMA CDV 797 To Fees on 4/2/97.

Rtmed frm fees on 4/8/97.

4/1/97 97-27 Compton 1 FEMA CDV 791, CDV-792 To Fees on 4/2/97.

Rtmed frm fees on 4/8/97.

4/1/97 97-28 Compton 1 FEMA COV-790 Model 1 To Fees on 4/2/97.

Rtmed frm fees on 4/8/97.

5 Sealed Source Safety Section

Pending Sealed Source & Device Actions Actions received during the period 1/1/01 to 3/12/98 For actions recorded as of Thursday, March 12,1998

{

1 I

Uile Assign. #

Received Reviewer Actions Company Model Numbers Status 5/9/97 97-34 Compton 1 PSI Powertronic Drift Tube Assembly N/A to Fees

Systems, Def. ltr sent on 12/24/97.

Fax dated 2/17/98. req. for extension.

j 5/15/97 97-38 Broaddus 1 Apgee Corporation Model LB AS To and rtmed frm Fees on 6/3/97.

2.202 response Fee exempt Def. mtg on 8/14/97.

Def. resp. revd on 10/3/97.

5/20/97 97-39 Broaddus 1 Apgee Corporation Model LB 330 To and rtmed frm Fees on 6/3/97.

2.202 response Fee exempt Def. mtg. on 8/14/97.

Def. resp. revd on 10/3/97.

Inactive request dated 12/5/97.

6/2/97 9741 Compton 1 ES Industnes D42 To Fees on 6/4/97.

Rtmed frm fees on 6/10/97.

6/3/97 97-37 Broaddus 1 Apgee Corporation LB 300 IPD/L To and rtmed frm Fees on 6/3/97.

2.202 response Fee exempt Def. mtg. on 8/14/97.

Def. resp rcvd on 10/3/97.

Inactive requested dated 12/5/97.

6/12/97 97-42 Jankovich 1 Apgee Corporation LB 379 To Fees on 6/12/97.

Rtmed frm fees on 6/16/97.

Inactive request dated 12/5/97.

6 Sealed Source Safety Section

1 Pending Sealed Source & Device Actions I

Actions received during the period 1/1/01 to 3/12/98 l

For actions recorded as of Thursday, March 12,1998 I

Date Assign. #

1 Received Reviewer Actions Company Model Numbers Status 6/12/97 97-43 Jankovich 1 Apgee Corporation LB 300 ULP To Fees on 6/12/97.

Rtmed frm fees on 6/16/97.

Inactive request dated 12/5/97.

Ltr frm applicant on 12/18/97 requesting that case remain active until 2/1/98.

l 6/12/97 97 44 Jankovich 1 Apgee Corporation LB 300 IRL To Fees on 6/12/97.

Rtmed frm fees on 6/16/97.

Inactive request dated 12/5/97.

Ltr frm applicant on 12/18/97 requesting that case remains active until 2/1/98.

6/12/97 97-45 Jankovich 1 Apgee Corporation LB 300 MUMLT To Fees on 6/12/97.

Rtmed frm fees on 6/16/97 6/16/97 97-46 Jankovich i Apgee Corporation LB 300 ML/MLT To Fees on 6/16/97.

See also 97-45 Rtmed frm fees on 6/18/97.

6/17/97 97-4' Compton 1 Stocker & Yale P650 To Fees on 6/17/97.

Rtmed frm fees on 2/18/98.

Continuation of 97-59.

6/20/97 97-48 Compton 1 Allegheny University SrO.A53 To Fees on 6/20/97.

Hosp.

Rtmed frm Fees on 9/16/97.

Def. Itr sent on 1/15/98.

I 7

Sealed Source Safety Section u_______-----___

Pending Sealed Source & Device Actions Actions received during the period 1/1/01 to 3/12/98 For actions recorded aS of Thursday, March 12,1998 Date Assign. #

Received Reviewer Actions Company Model Numbefs Status 8/14/97 97-55 Smith 1 Walter Kidde Port.

SMD1,0805,0905,0906,0908, To Fees on 8/21/97.

Equip.

0914,0916, 0918 Rtrned frm fees on 9/5/97.

8/20/97 97-57 Lee 1 Edwards Systems Tech 305 Senes,235 Series To Fees on 8/21/97, (EST)

Rtrned frm fees on 10/8/97, 9/2/97 97-59 Lee 1 Stocker & Yale 80800,490,184-B,184-B1, To Fees on 9/5/97.

5903,5904,5905 Rtmed frm fees on 9/26/97.

9/9/97 97-60 Lee 1 TSI incorporated Models 3012,3054,3013,3078 To Fees on 9/10/97.

Rtmed frm fees on 10/23/97.

9/23/97 97-61 Lee 1 Lockheed Martin 5310,5310-1,5310-3,5310-5 To Fees on 9/23/97, Rtmed frm fees on 9/26/97.

Def. ftr sent on 2/19/98.

9/26/97 97-62 Lee i Universal Secunty Inst. Series SS-750 To Fees on 9/29/97.

Rtmed frm fees on 10/6/97.

Action is a continuation of 95-01 and 94-38.

10/14/97 97-63 Burgess 1 Perkin Elmer Voyager To Fees on 10/15/97 Def. call on 10/28/97.

Rtmed frm fees on 11/7/97.

Def. call on 11/4/97.

Def. resp. rovd on 1/6/98.

Def. call on 2/3/98.

Def. resp. revd on 2/4/98.

8 Sealed Source Safety Section

Pending Sealed Source & Device Actions Actions received during the period 1/1/01 to 3/12/98 For actions recorded as of Thursday, March 12,1998 Date Assign. #

Received Reviewer Actions Company Model Numbers Status 10/20/97 97-64 Jankovich 1 Motorex, Inc.

HEPS, LEPS, DOPS, SAPS, To Fees on 10/22/97.

SSPS,SLPS Rtrned frm fees on 11/3/97.

Case has been reassened to J. Jankovich on 2/4/98.

10/20/97 97-66 Lee 1 Motorex, Inc.

Courier 20 To Fees on 10/22/97.

Rtmed frm fees on 11/3/97.

Case has been reassigned to S. Lee as of 2/2/98.

]

10/24/97 97-67 Compton i EAD Metallurgical, Inc.

AMX 1100 FOIL To Fees on 10/24/97 Rtmed frm fees on 11/3/97 10/24/97 97-68 Compton 1 EAD Metallurgical, Inc.

AMX-11N1, AMX 11N2 To Fees on 10/24/97.

Rtmed from fees on 11/3/97 11/19/97 97-71 Lee 2 Litton Medical Products Toshiba RCR 120 To Fees on 11/20/97.

Rtmed frm fees on 11/25/97.

Case has been reassigned to S. Lee on 2/2/98.

11/19/97 97-69 Compton 1 Memck Scale Merrick Scale NCPM To Fees on 11/20/97.

Rtmed frm Fees on 11/25/97.

11/19/97 97-70 Cunpton 5 Parkwell Lab, Inc.

PL-AMBE, AM, AC, PL-200 To Fees on 11/20/97.

Rtmed frm Fees on 11/25/97.

12/5/97 97 75 Jankovich 1 MDS Nordion C-337A To Fees on 12/9/97.

Def. Itr sent on 12/12/97.

Lir dated 2/6/98 requesting extension.

{

r 9

Sealed Source Safety Section l

l

1 Pending Sealed Source & Device Actions Actions received during the period 1/1/01 to 3/12/98 For actions recorded as of Thursday, March 12,1998 Date Assign. #

Received Reviewer Actions Company Model Numbers Status 12/9/97 97-79 Kirkwood 1 Amencan Sensors SA 4, 300, Micro 300, 330, 350 To Fees on 12/11/97.

Series Rtrned frm fees on 12/30/97.

Action has been transferred to T.Kirkwood on 2/19/98.

12/9/97 97-76 Lee 1 Apgee Corporation LB BW To Fees on 12/10/97.

Rtmed frm fees on 12/30/97.

12/9/97 97 77 Lee 1 Apgee Corporation LB 375 To Fees on 12/10/97.

Rtmed frm fees on 12/30/97.

12/9/97 97-78 Lee i Dept. of the Army ACADA To Fees on 12/11/97.

Rtmed frm fees on 12/30/97.

12/19/97 97-83 Lee 2 Nuclear Research SH-300 Series. LS-101 To fees on 12/30/97.

Corp, 12/19/97 97-80 Lee 1 RSNP RSNP-AU To Fees on 12/29/97.

12/19/97 97-81 Lee 1 RSNP RSNP-IR, RSNP-2 To Fees on 12/29/97.

12/30/97 97-82 Lee 1 intergrated Ind.

RSS-06 To Fees on 12/30/97.

Systems Rtmed frm fees on 2/6/98.

1/5/98 98-01 Lubinski 1 Dynalec Corporation IC/SF (3499),3464,3466 To Fees on 1/5/98 Def callon 1/6/98.

10 Sealed Source Safety Section

Pending Sealed Source & Device Actions Actions received during the period 1/1/01 to 3/12/98 For actions recorded as of Thursday, March 12,1998 Date Assign. s Received Reviewer Actions Company Model Numbers Status 1/5/98 98-02 Lee 1 Seaman Nuclear Corp.

C-100, C-200 To Fees on 1/5/98 Rtrned frm fees on 1/14/98 Continuation of 95115 Action has been reassgned to S. Lee on 1/29/98 1/5/98 98-03 Lubinski 1 Wing Corporation IC/SF (3499) 3464,3466 To Fees on 1/6/98 l

Def. call on 1/6/98 Def. resp. revd on 2/9/98 1/6/98 98-05 Lee i Seaman Nuclear Corp.

C-300 To Fees on 1/7/98 Case has been reassgW to S. Lee on 1/29/98 1/9/98 98-06 Lee 5 Mallinkrodt 5540, 5541, 5542, Models N/A to Fees 006-01S Elutek 6724 1/15/98 98-08 Jankovich 1 MDS Nordion C-188 To Fees on 1/20/98 Rtmed frm fees on 17/98 1/15/98 98-09 Jankovich 1 MDS Nordion Gammacell 1000/3000 To Fees on 1/20/98 Rtmed frm fees on1'2/98 2/4/98 98-10 Lee 1 Ebertine instrument 8150-120-CS To Fees on 2/18/98 Corp.

Rtmed frm fees on 2/18/98 2/4/98 98-11 Lee 1 Eberline Instrument 8150-xxxAB To Fees on 2/18/98 Corp.

Rtmed frm fees on 2/18/98 2/4/98 98-12 Lee 1 Eberline instrument 1000 To Fees on 2/18/98.

Corp.

Rtrned frm fees on 2/18/98 2/4/98 98-13 f

Lee 1 Eberline Instrument 64-764 To Fees on 2/18/98.

j Corp.

Rtmed frm fees on 2/18/98.

11 Sealed Source Safety Section l

Pending Sealed Source & Device Actions Actions received during the period 1/1/01 to 3/12/98 For actions recorded aS of Thursday, March 12,1998 Date Assign. #

Received Reviewer Actions Company Model Numbers Status 2/4/98 98-14 Lee 1 Eberline Instrurw.'.i 1000 B To Fees on 2/18/98.

Corp..

Rtrned frm fees on 2/18/98.

2/4/98 98-15 Lee 1 Eberline Instrument SCS 1001-1008 To Fees on 2/18/98.

Corp.

Rtmed frm fees on 2/18/98.

2/4/98 98-16 Lee 1 Eberline Instrument DNS-5 To Fees on 2/18/98.

Corp.

Rtmed frm fees on 2/18/98.

2/4/98 98-17 Lee i Eberline Instrument DNS-SA To Fees on 2/18/98.

Corp.

Rtrned frm fees on 2/18/98, l

2/4/98 98-18 Lee 1 Eberline Instrument S94-1, S94-2, S94-4 To Fees on 2/18/98.

Corp.

Rtmed frm fees on 2/18/98.

2/4/98 98-19 Lee 1 Eberline Instrument DNS-7. DNS-10, DNS-17 To Fees on 2/18/98.

I Corp.

Rtmed frm fees on 2/18/98.

2/4/98 98-20 Lee 1 Eberline Instrument DNS-1, DNS-18, DNS-21 To Fees on 2/18/98.

Corp.

Rtmed frm fees on 2/18/98.

1 2/4/98 98-21 l

Lee 1 TMA/Ebertine CS-1, CS-3, CS-10, CS 12, To fees on 2/18/98.

CS-15, CS-16 Rtrned frm fees en 2/18/98.

2/4/98 98-22 Lee 1 TMA/Ebertine CS-7A, CS-7B To fees on 2/18/98.

Rtmed frm fees on 2/18/98.

2/4/98 98-23 Lee 1 TMA/Eberinne DNS-26 To fees on 2/18/98.

Rtmed frm fees on 2/18/98.

2/4/98 98-24 Lee 1 TMA/Eberline DNS-8, DNS-9 To fees on 2/18/98.

Rtmed frm fees on 2/18/98.

2/4/98 98-25 Lee 1 TMA/Eberline DNS-6 To fees on 2/18/98.

l Rtmed frm fees on 2/18/98.

12 Sealed Source Safety Section

Pending Sealed Source & Device Actions Actions received during the period 1/1/01 to 3/12/98 For actions recorded aS of Thursday, March 12,1998 Date Assign. s Received Reviewer Actions Company Model Numbers Status 2/4/98 98-26 Lee 1 TMA/Ebertine DNS-4, DNS-11, S-1 To fees on 2/18/98.

Rtmed frm fees on 2/18/98.

2/4/98 98-27 Lee i TMA/Eberkne DNS-2, DNS-14 To fees on 2/18/98.

Rtmed frm fees on 2/18/98.

2/4/98 98-28 Jankovich 1 The Source, Inc.

TS-241-Alpha N/A to fees 2/4/98 98-29 Jankovich 1 The Source, Inc.

TS-241 N/A to fees 2/19/98 98-31 Jankovich 1 MDS Nordion C-188 To Fees on 2/23/98.

Acknowledgment Ltr sent on 3/5/98.

2/27/98 98-32 Kirkwood 1 Kidde Safety CPD 705X SMOKE DETECTOR To Fees on 2/27/98.

Acknowledgment Ltr sent on j

3/5/98.

3/2/98 98-33 Unassigned 1 Dept. of the Air Force To Fees on 3/2/98 98-34 Unassigned 1 Ohmart Corporation SHRH-A To Fees on 3/2/98.

Acknowledgment Ltr sent on 3/5/98.

3/3/98 98-35 Jankovich 1 MDS Nordion Gammacell 40 To Fees on 3/3/98.

Acknowledgment ltr sent on 3/5/98.

l 3/5/98 98-38 Unassigned 1 Advanced Gauging AGT 400 To Fees on 3/5/98.

Acknowledgment Ltr sent on 3/9/98.

13 Sealed Source Safety Section l

i

Pending Sealed Source & Device Actions Actions received during the period 1/1/01 to 3/12/98 For actions recorded as of Thursday, March 12,1998 Date Assign. s Received Reviewer Actions Company Model Numbers Status I

3/5/98 98 37 Broaddus 1 EG&G Berthold LB7400 series To Fees on 3/9/98.

Acknowledgment Ltr sent on l

3/9/98.

l Total Open Case (s) is 91 Totaling 102 Action (s) i l

l I

14 Sealed Source Safety Section I