l NRC FORM 618 U.s. NUCLEAR RE2uLATORY COMMISSloN om CERTIFICATE OF COMPLIANCE
'0 C" FOR RADIOACTIVE hiATERIALS PACKAGES 1.a. CERTIFICATE NUMBER
- b. REVISION NUMBER
- c. PACKAGE IDENTIFICATION NUMBER d PAGE NUMBER e TOTAL NUMBER PAGES 6613 8
USA /6613/B(U) 1 2
- 2. PREAMBLE '
l
- a. This certificate is issued to certify that the packaging and contents described in item 5 below, meets the applicable safety standards set fonh in Title 10, Code of Federal Regulations, Part 71, Packaging and Transportation of Radioacthe Material."
- b. This certificate does not reheve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transportation or other tpphcable regulatory agencies, including the government of any country through or into *hich the package will be transported.
- 3. THis CERTIFICATE IS ISSUED ON THE B ASIS OF A SAFETY ANALYSIS REPORT OF THE PACK AGE DESIGN OR APPLICATION
- a. ISSUED TO(Name and Addren)
- b. TITLE AND IDENTIRCATION OF REPORT OR APPLICATION:
Amersham Corporation Amersham Corporation application dated 40 N:rth Avenue November 27,1991, as supplemented.
Burlington, MA 01803
- c. DOCKET NUMBER 7j.6613
- 4. CONDmONS Ti is c:rtificate is conditional upon fulfilling the requirements of 10 CFR Part 71, as applicable. and the conditions specif;ed below.
t S.
(a)
Packaging l
(1)
Model No.: 702 (2)
Description The cask system overall dimensions are 19" x 21" x 20". The cask is a stainless steel weldment containing depleted uranium shielding. The cask has a central cavity which is 2.26 inches in diameter by 3.26 inches long. Closure is accomplished by a neoprene gasket, six,3/8-inch bolts and a stainless steel stepped plug containing depleted uranium shielding. The closure is equipped with an eye bolt and two drain and vent plugs. The cask is mounted on a 19" x 21" rectangular steel skid with four,1/2-inch bolts and a tie-i down system consisting of four,1/2 inch diameter threaded rods which connect a clamp ring at the top of the cask to channel brackets welded to the skid. A protsetive cage i
constructed of 1-1/4 inch square steel tubing and perforated 18 geuge steel sheets tack welded to the tubular frome surrounds the cask and is bolted to the skid by four,1/2 inch bolts. Maximum gross weight of the packaging is 410 pounds.
(3)
Drawings The cask and other system components are constructed in accordance with Technical Operations, Inc. Drawing Nos.: 70290, Sheet 1 to 4, Rev. D.
9806090071 980602 PDR ADOCK 07106613 C
PDR ELa m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m, m a m m m m m m m m m,
5
. kl g'jf FORM 818A 00NDmoNs vroeirma,41 U.s. NUCLEAR REluLAToRY OMM:OsloN b
ll g #l Page 2 - C2rtificats No. 6613 - R2 vision No. 8 - D:cket No.
B 71-6613 g
Nl E
Contents N
i 5. (b)
E N
l f
(1)
Type and form of material I
i i
p Metallic iridium-192 sources which meet the requirements of special form g
g radioactive material.
g 9
I p
(2)
Maximum quantity of material per package g
5l E
B 10,000 curies (output).
g I
N 9l Output curies are determined in accordance with American National Standard N432-l h
1980, " Radiological Safety for the Design and Construction of Apparatus for Gamma N
9 Radiography."
E Il N
(3)
Maximum decay heat per package 100 watts.
p 6.
The name plate must be fabricated of materials capable of resisting the fire test of 10 CFR Part g
El p
71 and maintaining their legibility.
g l
I i
7.
In addition to the requirements of Subpart G of 10 CFR Part 71:
g 5
i B;
(a)
Each package shall be operated and prepared for shipment in accordance with Section 7.0 g
5 of the application, as supplemented.
l Nl d
N}j (b)
The package must meet the Acceptance Tests and Maintenance Program, Section 8.0 of I
N i
the application, as supplemented.
N B
g l
8.
The package authorized by this certificate is hereby approved for use under the general license N
p provisions of 10 CFR 671.12.
I I
l p
9.
Expiration date: June 30,2003.
y I
d j
b BEFERENCES g
E I
i Amersham Corporation application dated November 27,1991.
g Ij N
Bl Supplements dated: April 20, December 1,1992; March 19 and 26,1993; March 1,1996; and q
I{ January 9,1998.
I E
N lN' I
FOR THE U.S. NUCLEAR REGULATORY COMMISSION E
b 4
i
,l p
Cass R. Chappell, Chief g
{
p Package Certification Section g
b; Spent Fuel Project Office ql B;.
Office of Nuclear Material Safety ll B;
and Safeguards d
b a m m: m7m m m m m m m m m m m m m m m m E
Date June 2,1998 l
g
.,fp*"4g
\\
s.
- y o
g i
UNITED STATES g
j NUCLEAR REGULATORY COMMISSION e
f WASHINGTON. D.C. 30086 0001
'+9.....,o APPROVAL RECORD Model No. 702 Certificate of Compliance No. 6613 Revision No. 8 By application dated January 9,1998, Amersham Corporation requested renewal of Certificate of Compliance No. 6613 for the Model No. 702 package. Amersham Corporation did not request any changes to the package design or authorized contents.
The staff has reviewed the operating procedures and the maintenance program and found them to be complete and adequate.
The Certificate of Compliance has been renewed for a five year period which expires June 30, 2003.
es M Cass R. Chappell, Chief Package Certification Section Spent Fuel Project Office Office of Nuclear Material Safety and Safeguards Date: June 2,1998 i