ML20248G894

From kanterella
Jump to navigation Jump to search
Informs That on 961203,Office of Investigations Initiated Investigation to Determine Whether Former Contract Security Dept Employee Terminated in July 1996 for Raising Safety Concern.Insufficient Evidence to Substantiate Claim
ML20248G894
Person / Time
Site: Haddam Neck File:Connecticut Yankee Atomic Power Co icon.png
Issue date: 05/28/1998
From: Blough A
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Mellor R
CONNECTICUT YANKEE ATOMIC POWER CO.
References
NUDOCS 9806050384
Download: ML20248G894 (2)


Text

-

May 28, 1998 1

i Mr. R. A. Mellor, Vice President Operations and Decommissioning Connecticut Yankee Atcmic Power Company J

362 Injun Hollow Road East Hampton, CT 06424-3099

Subject:

01 Investigation 1-96-045

Dear Mr. Mellor:

On December 3,1996, the NRC Office of Investigations (01) initiated an investigation to determine whether a former contract security department employee was terminated in July 1996, for raising a safety concern. During the course of the investigation, an additional concern was raised that the employee was being " blackballed" by the security contractor.

The NRC has completed a coordinated review of this matter by the Office of Enforcement, the Office of Investigations, the Office of General Counsel, the Special Projects Office, and NRC Region I. We have concluded that there was not sufficient evidence to substantiate that the former contractor was discriminated against for raising safety concerns.

i in accordance with 10 CFR 2.7'90 of the NRC's " Rules of Practice," a copy of this letter will be placed in the NRC Public Document Room.

Sincerely, Original Signed By:

A. Randolph Blough Director, Division of Nuclear Materials Safety

\\h\\)

Au.

V' 9806050384 980520 PDR ADOCK 05000213 y

PDR l

l OFFICIAi. RECORD COPY u----

Mr. R. A. Mellor 2

Distribution w/ encl:

PUBLIC Region i Docket Room (w/ concurrences) bec: Allegation File No. RI-96-A-0257 DOCUMENT NAME: P:

3 Ta receive a copy of th6e document, indicate in the box: 'C" = Copy without attachment / enclosure

  • E' = Copy with attachment / enclosure "N* = No copy OFFICE ORA / SAC DNMS/DLB DNMS/DD l

OI:Rl/FOD ORA:RC, NAME DVito Lh1 MMiller W RBlough BLetts ykh BFewel@

DATE 05fa-/98 1

05pfl98 05/ /98 05/u/98 05GJ98'

{

OFFICE ORA /EO OE/DIR l

l NAME DHolody Mg JLieberman l

DATE 05M98 05W 98 05/ /98 gg CORD COPY hmL V'~ 9 p L.

' eb t