ML20248B575
| ML20248B575 | |
| Person / Time | |
|---|---|
| Site: | Rancho Seco |
| Issue date: | 06/02/1989 |
| From: | Croley B SACRAMENTO MUNICIPAL UTILITY DISTRICT |
| To: | NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM) |
| References | |
| AGM-NTS-89-143, IEB-88-011, IEB-88-11, NUDOCS 8906090106 | |
| Download: ML20248B575 (2) | |
Text
_ - _ _.. _ _ _ _ - _
) h';
L; p.
p.s ).suun SACRAMENTO MUNICIPAL UTILITY DISTRICT D 6201 S Street, P.o. Box 16830. Sacramento CA 95852-1830,1916) 452 3211 AN ELECTRIC SYSTEM SERVING THE HEART OF CALtFORNIA AGM/NTS'89-143 June 2, 1989 U. S. Nuclear Regulatory Commission Attn: Document Control. Desk Hashington, DC 20555 Docket No. 50-312 Rancho Seco Nuclear Generating Station License No. OPR-54 NRC BULLETIN NO. 88-11: PRESSURIZER SURGE LINE THERMAL STRATIFICATION Attention: George Knighton
Reference:
Babcock & Hilcox Owners Group letter to NRC dated May 23, 1989, Babcock & Hilcox Owners Group Submittal in Response to NRC Bulletin 88-11.
.The referenced letter transmitted the B&H Owners Group report which describes the investigations completed.to date in' response to item lb of Bulletin 88-11. As stated in the District's letter to the NRC on this subject dated March 6,1989, the evaluation of the effects of thermal striping will be submitted on or before October 31, 1989.
Bulletin 88-11 requests that a justification for continued operation be provided if a bounding analysis does not support the full licensed pressurizer surge line lifetime. Based on a review of the B&W Owners Group report and its applicability to Rancho Seco, it has been determined that although the
. licensed lifetime has not yet been supported by analysis, the Rancho Seco pressurizer surge line is conservatively acceptable until June 1994.
The bounding analysis completed to date is supported by visual and ASME Section XI inspections which have revealed no abnormalities associated with the surge line.
It is anticipated that the final analysis, including an evaluation of.both stratification and striping, will conservatively support a surge line lifetime significantly longer than the June 1994 date.
Members of your staff with questions requiring additional information or clarification may contact Mr. Steve Rutter at (209) 333-2935, extension 4911.
8906090106 890602
'{DR ADOCK 0500 2
go
' \\
RANCHO SECO NUCLEAR GENERATING STATION D 1444o Twin Cities Road, Herald, CA 95638 9799;(209) 333 2935
George Knighton AGM/NTS89-143 s
State of California SS County of Sacramento Bob G. Croley, being first duly sworn, deposes and says:
that he is Assistant General Manager, Nuclear Technical Services of Sacramento Municipal Utility District (SMUD), the licensee herein; that he has executed the foregoing document; that the statements made in this document are true and correct to the best of his knowledge, information, and belief, and that he is authorized to execute this document on behalf of said licensee.
/
/ Bob G. Croley
/
Assistant General Ma, nager Nuclear Technical SIervices Subscribed and affirmed to before me on this d day of b
,1989.
M [ [vA r-----
{
[, g ^c b ic
'^
3 y
MY CONM. EXP. NOV. 20, 1992 ;
3 cc:
J. B. Martin, NRC, Halnut Creek A. D'Angelo, NRC, Rancho Seco l
l
~
.. - -. _ - - - _ - _ _ - - _ _ _. - - _