Amend 182 to License DPR-20,revising TS Re Insp Requirements for Reactor Coolant Pump Flywheels
ML20248A047
Person / Time
Site: Palisades 
(DPR-20-A-182)
Issue date: 05/15/1998
From: Robert Schaaf
NRC (Affiliation Not Assigned)
To:
Shared Package
ML20248A053 List:
References
NUDOCS 9805290278
Download: ML20248A047 (3)


Text

_ _ _ _ _ - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _

. p utuq k

~

UNITED STATES g

g

,j NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20665-0001 p

t

/

CONSUMERS ENERGY COMPAIMy DOCKET NO. 50-255 PALISADES PLANT AMENDMENT TO FACILITY OPERATING LICENSE Amendment No.182 License No. DPR-20 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

The application for amendment by Consumers Energy Company (the licensee) dated January 18,1996, as supplemented October 1,1997, and January 29 and April 27,1998, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity v.ith the application, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public; and (ii) that such activities will be conducted in compliance with the Commission's regulations; I

D.

The issuance of this amendment will not be inimical to the cominon defense and security or to the health and safety of the public; E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to the license amendment and Paragraph 2.C.(2) of Facility Operatirig License No. DPR-20 is hereby amended to read as follows:

The Technical Specifications contained in Appendix A, as revised through Amendment No. 182

, and the Environmental Protection Plan contained in Appendix B are hereby incorporated in the license. Consumers Energy Company shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.

3.

This license amendment is effective as of the date of issuance.

FOR TH NUCLEAR REGU TORY COMMISSION

  • "0" 9805290278 980515 PDR ADOCK 05000255 Project Directorate lil-1 P

PDR Division of Reactor Projects - lil/IV Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of Issuance: May 15, 1998 I

f i

ATTACHMENT TO LICENSE AMENDMENT NO.182 l

FACILITY OPERATING LICENSE t@ DPR-20 DOCKET NO. 50-255 Revise Appendix A Technical Specifications by removing the pages identified below 1

inserting the attached pages. The revised pages are identified by amendment number and contain verticallines indicating the areas of change.

REMOVE INSERT 6-8 6-8

L l

.p 6.0 ADMINISTRATIVE CONTROLS l

L 6.5.5 Reserved f

l 1

6.5.6-

. Primary Coolant Pumo Flywheel Surveillance Proaram j

^

Surveillance of the primary coolant pump flywheels shall consist of a 100% volumetric inspection of the upper flywheels each 10 years.

6.5.7-Inservice Insoection'and Testina Proaram i

This program provides controls for inservice inspection and testing of l

ASME Code Class 1, 2, and 3 components including applicable supports.

The program shall include the following:

l a.

Testing frequencies specified in Section XI of the ASME Boiler and Pressure Vessel Code and applicable Addenda (B&PV Code) as follows:

l B&PV Code terminology Required interval

.for inservice testing

.for performing inservice activities-testina activities Weekly

.s 7 days-Monthly-s 31 days Quarterly or every 3 months s 92 days Semiannually or every 6 months s 184 days 1

Every 9 months s 276 days Yearly or annually s 366 days Biennially or every 2 years s 731 days b.

The provisions of Surveillance Requirement 4.0.2 are applicable to the above required intervals for performing inservice testing activities; c.

The provisions of Surveillance Requirement 4.0.3 are applicable to inservice testing activities; and I

d.

Nothing in the B&PV Cot; shall be construed to supersede the requirements of any Technical Specification.

j 6-8 Amendment No. W 4, W 4, 182 L