ML20247R604

From kanterella
Jump to navigation Jump to search
Registry of Radioactive Sealed Sources & Devices,Safety Evaluation of Gauge Sealed Source for Models 3E4L & 3E4S. Certificate:NR-460-S-909-S
ML20247R604
Person / Time
Issue date: 01/26/1996
From: Steven Baggett, Doug Broaddus
NRC
To:
Shared Package
ML20247R609 List:
References
SSD, NUDOCS 9805290184
Download: ML20247R604 (6)


Text

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE NO.: NR-460-S-905-S DATE: January 26, 1996 PAGE 1 OF 6 SEALED SOURCE iYPE; Gauge Source MODEL:

3E4L, 3E4S MANUFACTURER / DISTRIBUTOR:

3M Health Physics Services 3M Center, Building 224-2E-06 St. Paul, MN 55144-1000 ISOTOPE:

MAXIMUM ACTIVITY:

Krypton-85 1,000 millicuries (37.00 GBq)

LEAK TEST FREOUENCYi Not Required l

PRINCIPAL USE:

(R) Gas Sources f

I l

CUSTOM SOURCE:

YES X

NO 1

9905290184 960126 l

PDR RC SSD PDR MKT f

W D T

1 1

. REGISTRY,OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY" EVALUATION OF SEALED SOURCE l

l NO..: NR-460-S-909-S.

.DATE: January 26, 1996 PAGE 2 OF 6-l' l

SEALED SOURCE TYPE:

Gauge Source l

l DESCRIPTION:-

The Models:3E4L~and 3E4s are singly-encapsulated gas. sources.

p

' They consist _of a main housing, a small' copper tube, a nameplate, l

. and a window.

The housing is a 0.750 in.-(1.905 cm) long,

' O.865 in. (2.197 cm) outer diameter, and 0.700 in..(1.778 cm) inner. diameter. cylinder with'a 0.060 in. (0.152 cm) thick wall dividing ^itLinto two chambers.

The. larger chamber is O'375-in.

(0.953.cm).long, while.the smaller chamber is-0.315 in.

~

i (0.800 cm) long.

A 0.063 in.- (0.160 cm) diameter hole.is drilled l

. throughithe internal wall.. separating-the two chambers, and a 0.063 in. (0.160 cm) ~ outer diameter copper tube is inserted through the hole and silver brazed in place.

A window is gold brazed across the opening of the large chamber.

The window is

- 0.002 ins (0.005'cm) thick-for-the Model 3E4L and 0.001 in.

(0.003;cm)cthick for.the Model 3E4S.

The brazing around the tube-and window completely seal the large chamber.

Krypton-85 (Kr-85) gas is pumped into the large chamber through the copper tube.-

After theLlarge chamber'is filled, the tube is crimped off and silver brazed shut, completely sealing the.Kr-85 gas inside.

. Finally, a 0.750 in. (1.905 cm) diateter, 0.060 in. (0.152 cm)

. thick;name plate is inserted into a 0.755:in. (1.918 cm) l_

diameter, 0.070 in. (0.178 cm) long area in'the opening of the small' chamber and epoxied in place.. The housing, window, and nameplate are all made-from type 304 stainless steel.

DIAGRAM:

See Attachment 1.

i LABELING:

l-

.The name plate has:the following information:

l l

3M Company XXXX mc'Kr-85 L

Model No.

Serial No.

Date-

[-';

o

l-REGISTRY OF RADIOACTIVE SEALED SOURCES AND-DEVICES SAFETY EVALUATION OF SEALED SOURCE NO.: NR-460-S-909-S DATE: January 26, 1996 PAGE 3 OF 6 l

.1 SEALED SOURCE TYPE:

Gauge Source

' CONDITIONS OF NORMAL USE:

q The Models 3E4L and 3E4S sources are intended'for use in gauging applications;'

PROTOTYPE TESTING:

l 3M reported that prototypes of the Models 3E4L and 3E4S have been fabricated and tested using the quality control tests:shown-in l

this registration.

Also, the sealed sources.have.been approved

'by the' Atomic Energy Commission for licensing purposes as early as 1968.

Additionally, in 1982, a sample 3E4L source was retested in accordance with the specifications of ANSI N542-1977'andLachieved p

a classification of 77C32231.

EXTERNAL RADIATION LEVELS:

-The' manufacturer did not provide external radiation data for this source..However, given the design and construction of this source is similar to the model 3E40 source-that contains a 0.002 L

in.-(0.005 cm) window, the external: radiation levels would be expected-to be similar to this source.

3M provided the following dose rates ~for a Model 3E40 source containing 1.0 Ci (37 GBq)

-Kr-85.

DOSE RATES ~

. POSITION-5 cm (1.969 in.)

30 cm (11.81 in.)

l 1 Normal,to window.( )

1100 r/hr*

40 r/hr 11 Sv/hr' 400 mSv/hr' 1:

Normal-to long side (y) 140 mr/hr 25 mr/hr 1.4 mSv/hr 250 Sv/hr l

Normal to back side ~(y)-

100 mr/hr 20 mr/hr 1.0 mSv/hr 200 Sv/hr

'* Estimated l

-2_

l I

\\

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES I

SAFETY EVALUATION OF SEALED SOURCE NO.: NR-460-S-909-S DATE: January 26, 1996 PAGE 4 OF 6 SEALED SOURCE TYPE:

Gauge Source OUALITY ASSURANCE AND CONTROL:

The following quality control procedures were followed during production of these sources:

1. The capsule was pressure tested to a minimum of three times the filling pressure.

Failure of this test was determined by the presence of bubbles when the capsule was immersed in water during application of the pressure.

2.

The radiation output of the source was measured after filling the capsule with Kr-85. gas, and again after 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

Significant reduction of the radiation level indicated leakage and failure of the source.

3. The completed source was placed in a closed container for a minimum of 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> and the air in the cont.'iner was monitored for the presence of krypton-85.

The presence of any significant quantity of krypton-85 in the container indicated failure of the source.

LIMITATIONS AND/OR OTHER CONSIDERATIONS OF USE:

These sources may be used only by persons specifically licensed by the NRC an or Agreement State.

Handling, storage, use, transfer, and disposal:

to be determined by the licensing authority.

This registration sheet and the information contained within the references shall not be changed without the written consent of the NRC.

SAFETY ANALYSIS

SUMMARY

The Models 3E4L and 3E4S sources are not current products manufactured or distributed by 3M Health Physics Services.

However, 3M Health Physics Services will continue to receive Models 3E4L and 3E4S sources for disposal.

1 i

l

_ -. _.. ______________j

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE NO : NR-460-S-909-S DATE: January 26,.1996 PAGE 5 OF 6 SEALED SOURCE TYPE:

Gauge Source SAFETY ANALYSIS

SUMMARY

(continued)'

Based on our review of the Models 3E4L and 3E4S sources, and the information and test data cited below, we continue to conclude that these sources are acceptable for specific licensing purposes.

Furthermore, we continue to conclude that the Models 3E4L and 3E4S sources would be' expected to maintain their containment integrity for normal conditions of use and accidental conditions which might occur during uses specified in this certificate.

REFERENCES:

The following supporting documents for the Models 3E4L and 3E4S sealed sources are hereby incorporated by reference and are made a-part of this registry document:

3M Health Physics Services' letters dated August 6,

1991, and March 21, 1968, with enclosures thereto ANSI Tests - Reclassification Radioactive Sources, Static Control Systems /3M - Test Report dated August 31, 1982 ISSUING AGENCY:

U.S. Nuclear Regulatory Commission I-Date:

January 26, 1996 Reviewer:

<v r

ou as A.

Broaddus Date:

January 26, 1996 Concurrence:

Steven L.

Baggett I

'l___________________________.______

L

t T

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION-OF SEALID SOURCE NO.: NR-460-S-909-S DATE: January 26, 1996 ATTACHMENT 1 r" ?l.r,,1.iQ n.? k? ' ~ '~ ;

  • 8 sj,.

a R kkh af*h..~a g.)

~

Z

'W2 t

WJ

[ $ 5 3'>'. t.

d g< g }

A 95$

P heG g yakti dE "DN 7 002 20 dd>y Qn;3 Y

4h J y f, u Z ul 4

d 2 0g.

Ed=j ig5h<

- e' M

O si n

~

'A'

-d V

iJ a) 7 0

'1 C ij No} ! tt 0

.p O

d) i 9

$ bi e

o z ej 0 4 0 0 Y

O O 3p 0 90 ' * =

i t.d y

) ()

.I l-2; 4 9

--w l

4 gg td ul

\\

ge J

o

    • e Q,

O r

  • I

' - ' 'o 2

n i

9 1,

i 2

/

.-I....

4 O

ro W

094*

J

-=

J ll

~ GI G *~

y.

9L G ' =e

= = OLO*

Y m

.J, t

,j 1

!l l [

d I-1J

-- s g

, 'f

[

~

,f I

da

_ _ /___ _

"j i

o a

d i

4 L--

4.-

. _j.

_.I Q

d i,

,g i

g_

O

'I l

h L

-~,

um

i n

j

,f **%q l

p*

L UNITED STATES j

NUCLEAR REGULATORY COMMISSION l

g

~ f WASHINGTON, D.C. 205!6 4001 o

l February 12, 1996 l

NOTE T0:

MINNESOTA MINING AND MANUFACTURING (3M) INACTIVE FILES k'1d FROM:

SUBJECT:

INACTIVATION OF REGISTRATIONS BASED ON AUGUST 6, 1991, LETTER.

A number of the background files for the registration certificates requested (by 3M letter dated August 6, 1991) to be made inactive contain limited information on the products. A search of 3M registration, archive, and license files, and information in NUDOCS was performed to obtain additional information. Also, 3M was contacted to obtain any additional information that may have been in their files.

3M provided limited additional information concerning these products and indicated that the information provided represented all additional information in their files. Additional information obtained from these sources has been added to the applicable registration files.

At the present time, the information contained in the background registration files represents all available information for these products.

In addition, a number.of these products were originally reviewed and approved by the Atomic Energy Commission (AEC).

The reviews performed for these products to make the certificates inactive were based on the information available, the previous reviews and approvals, and the historical use of the products (i.e., reports of failures or design problems, or the lack thereof).

In several instances, insufficient information was available to perform an adequate safety review.

In these instances, the certificates have been reissued based solely on the original AEC review and approval, and no additional safety review was performed.

/

l l

l l

/h

/I 'l_ b t

i /VU T/

i February 29, 1996 Robert G. Wissink 3M Health Physics Services 3M Center Bldg. 224-2E-06 St.-Paul, MN 55144-1000

Dear Mr. Wissink:

This letter is in response to your request dated August 6,1991, and subsequent letters, requesting to transfer to inactive status all registration sheets issued to 3M as listed in the first column of Enclosure 1.

We have transferred the requested certificates to inactive status. The certificate numbers have been changed as listed in Enclosure 1.

Copies of the inactive certificates.are enclosed for your records.

Please read over the registration certificates and notify us immediately if there are any errors or inconsistencies.

If you have any questions, please contact me at (301) 415-5847 or Mr. Steven Baggett at (301) 415-7273.

Sincerely,

/3 /

Douglas A. Broaddus, Mechanical Engineer q

Sealed Source Safety Section Source Containment and Devices Branch Division of Industrial and j

Medical Nuclear Safety, NMSS j

Enclosures:

As stated Distribution:

SSSS R/F NE01 SSD-91-71 Registration certificate files listed in Enclosure 1 DOCUMENT NAME: C:

n e n.em. m.\\WPDOCS\\SSDS\\ INACTIVE \\.NRC\\460lNACT. CMP

.me m

wn: c con w.m m.en,c.nw r - con wm m.*n.nu.nm w - u. con 0FFICE SCDB lC l

l l

l NAME DABroaddus DATE 02/27/96 l

OFFICIAL RECORD COPY

I ENCLOSURE 1 REGISTRATIONS TRANSFERRED TO INACTIVE STATUS Old Certificate No.

New Certificate No.

Model Number (s)

NR-459-S-101-S NR-8008-S-801-S 4F6Y NR-459-S-102-S NR-8008-S-802-S 3F1G NR-460-S-101-S NR-0460-S-875-S 4F60 NR-460-S-102-S COMBINED WITH 4F6H, 4F6B NR-0460-S-874-S NR-460-S-103-S NR-0460-S-876-S 4F6G NR-460-S-104-S COMBINED WITH 6D6A NR-0460-S-865-S NR-460-S-105-S NR-0460-S-877-S 6B6F NR-460-S-106-S NR-0460-S-878-S 4F6P NR-460-S-107-S NR-0460-S-879-S IC2A, 1C28 NR-460-S-108-S NR-0460-S-880-S 4F3B NR-460-S-109-S NR-0460-S-881-S 4F3C NR-460-S-110-S NR-0460-S-882-S 3MIC NR-460-S-111-S NR-0460-S-883-5 3MlB NR-460-S-112-S NR-0460-S-884-S 3E4G NR-460-S-113-S NR-0460-S-885-S 4D3A NR-460-S-ll4-S NR-0460-S-886-S 4D3B NR-460-S-115-S NR-0460-S-887-5 4D60 l

NR-460-S-116-S NR-0460-S-888-S 4D6F NR-460-S-117-S NR-0460-S-889-S 5FID NR-460-S-118-S COMBINED INTO SFIE

~~

NR-460-S-119-S 5FIF NR-460-S-120-S NR-0460-S-891-S 5 FIG NR-460-S-121-S NR-0460-S-892-S 3L2B NR-460-S-122-S NR-0460-S-893-S 3L2A NR-460-S-123-S NR-0460-S-894-S 3M1F NR-460-S-124-S NR-0460-S-895-S 3L2C l

i n

ENCLOSURE 1 REGISTRATIONS TRANSFERRED TO INACTIVE STATUS Old Certificate No.

New Certificate No.

Model Number (s)

FR-460-S-125-S NR-0460-S-896-S 1E2J NR-460-S-126-S NR-0460-S-897-5 3F1G NR-460-S-127-S NONE - NO INFORMATION 4FIE AVAILABLE NR-460-S-128-S NR-0460-S-899-S 5FIH NR-460-S-129-S NR-0460-S-900-S 3E40 NR-460-S-130-S COMBINED INTO 5 FIN NR-460-S-131-S NR-0460-S-901-S 5 FIN (MODIFIED)

NR-460-S-132-S NR-0460-S-902-S 788L NR-460-S-133-S COMBINED INTO 6H6A NR-460-S-134-S

~~

6H6B NR-460-S-135-S NR-0460-S-904-S 4D6M NR-460-S-136-S NR-0460-S-905-S 3L2E NR-460-S-137-S NR-0460-S-906-S 6500, 6520 (FORM. 606C)

NR-460-S-138-S NR-0460-S-907-S 3L2D NR-460-S-139-S NR-0460-S-908-S 3Q10 NR-460-S-140-S NR-0460-S-909-S 3E4L, 3E4S NR-460-S-141-S NR-0460-S-910-S 3 FIR NR-460-S-142-S NR-0460-S-911-S 902, 902F, 903 NR-460-S-143-S COMBINED WITH 4P6E NR-0460-S-871-S NR-460-S-144-S COMBINED WITH 4P6M l

NR-0460-S-872-S NR-460-S-145-S NR-0460-S-912-S 3Mll NR-460-S-146-S NR-0460-S-913-S 3G9A NR-460-S-147-S NR-0460-S-914-S 384G NR-460-S-148-S COMBINED WITH 4F3F NR-0460-S-871-S NR-460-S-149-S NR-0460-S-915-S 4F3G

t ENCLOSURE 1 REGISTRATIONS TRANSFERRED TO INACTIVE STATUS Old Certificate No.

New Certificate No.

Nodel Number (s)

NR-460-S-150-S NR-0460-S-916-5 6DIA NR-460-S-151-S COMBINED WITH 6530, 6540 (FORM. 6B6G)

NR-0460-S-869-S NR-460-S-152-S-NR-0460-S-917-S 6H6D NR-460-S-153-S NOT REQUlkED ALBUMIN MICR0 SPHERES NR-460-S-154-S NR-0460-S-919-S 6H6E, 8C9T NR-460-S-155-S COMBINED INTO 4D6L

~ ~'

NR-460-S-156-S 4D6P NR-460-S-158-S NR-0460-S-921-S 3F11, 3FlJ, 3FIL NR-460-S-159-S

'NR-0460-S-922-S 3FIV NR-460-S-160-S COMBINED WITH 4P6T NR-0460-S-873-S NR-460-S-161-S COMBINED INTO F1D NR-0460-S-920-S NR-460-S-162-S NR-0460-S-923-S 4F3H NR-460-S-163-S COMBINED INTO 4F6S NR-0460-S-920-S NR-460-S-164-S COMBINED WITH 3E40 NR-0460-S-900-S NR-460-S-165-S NR-0460-S-924-S 6701 NR-460-S-166-S NR-0460-S-925-S 6702 NR-460-S-167-S NR-0460-S-926-S 6711 NR-460-S-168-G NR-0460-S-927-G 702, 703, 704 NR-460-S-169-S NR-0460-S-928-S 6510, 6550, 6570 (FORMERLY 686G)

NR-460-S-170-S NR-0460-S-929-S 4P6V NR-460-S-171-S NR-0460-S-930-S 4F6ST

_m._.__.-...__._.-____:______.__a..

--_m._