D REGISTRY OF RADI0 ACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE (Amendedinentirety)
N0:
NR-460-S-106-S DATE:
PAGE 1 0F 7 JR.1~11964 SOURCE TYPE:
Strip Source
(
MODEL: 4F6P MANUFACTURER / DISTRIBUTOR: Minnesota Mining & Manufacturing Company TCAAP - Building 590 New Brighton, MN 55112 ISOTOPE:
MAXIMUM ACTIVITY:
Cesium-137 10 curies.
LEAK TEST ~ FREQUENCY: 6 months PRINCIPAL-USE:. (D) Gamma Gauge CUSTOM DEVICE:
YES X N0 3
l-n 9905290325 960126 i
PDR RC F
l-
.. z..SSD PDR l
7
E O
REGIS ev 0F RADI0 ACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE (Amended in entirety)
NO:
NR-460-S-106-S DATE:
PAGE 2 0F 7 ML 1L 1984 SOURCE TYPE:
Strip Source DESCRIPTION:
The source is a doubly encapsulated Cesium-137 source.
The material used in the source construction is 304 and 410 stainless steel.
The inner capsule is filled with inert ceramic microspheres containing the Cesium-137 material.
This is a cylindrical strip source 1/2" in diameter, varying in length from 2-1/2" to 73-1/2" (active length 1" to 72").
The sealed tube is encapsulated within an outer,1/2" 0.D., stainless steel tube witn plugs welded at both ends.
The wall thickness is 56 mils.
I l
LABELING:
Sources are labeled with serial number, isotope, active length and number of millicuries.
i I
I
)
ep a
REGISTRY OF RADI0 ACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE (Amendedinentirety)
N0:
NR-460-S-106-S DATE:
PAGE 3 0F 7 JUL 1 1 3!M SOURCE TYPE:
Strip Source DIAGRAM:
Item Description
'=
OUTER LENGTH = Active LENGTH + 4.50' 1
Ass'y Outer Tube ACTIVE LENGTH
=
4 3
5 2
Ass'y Inner Tube 3
Inner Plug t.
i s
'4 Braze:
Silver Cad Free Allstate 155
-j 5
Activity:
3M Brand Radiating Microspheres N%M.. /..
_ - - rr P - ~ ~
d:'.?=n "ing C -137 trumm%g=c. _
.=== $
r
- - - -- U 7 = 1I %
i y _ y _ _ _ _l n
- - g Id)
M-(b CONDITIONS OF NORMAL USE:
The sources are installed in various gaging devices made by the customers.
See the registration sheet for the conditions of use of the specific gaging device in question.
PROTOTYPE TESTING:
The manufacturer reports that the source has been tested in accordance with ANSI N542 requirements and has obtained a classification of 77C53346.
l l
eP e9 j
REGISTRY OF RADI0 ACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE l
(Amended in entirety)
I N0:
NR-460-S-106-S DATE:
PAGE 4 0F 7 JUL 111984 SOURCE TYPE:
Strip Source EXTERNAL RADIATION LEVELS:
The manufacturer calculated the following dose rates in mrem / hour for a 10 curie source using dose rates from a 4.5 and 5.0 curie source.
I i
Contact 5 cm 30 cm 100 cm 1000 cm 1.3 x 108 mr/hr 3.7 x 108 mr/hr 3 x 105 mr/hr 3400 mr/hr No contact readings have been calculated i
because the readings will vary a considerable amount depending on the l
length of the 4F6P strip source.
QUALITY ASSURANCE AND CONTROL:
The Quality Control group operates from policies and procedures described in the Static Control Systems Division Manual (New Brighton Plant).
The quality system is based on Mil-Q-9858-A guidelines on file with the NRC.
The orogram has been previously deemed acceptable for licensing purposes by the NRC.
REGISTRY OF RADI0 ACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE (Amendedinentirety)
N0:
NR-460-S-106-S DATE:
PAGE 5 0F 7 NL 1 y yp
. SOURCE TYPE:
Strip Source LIMITATIONS AND/0R OTHER CONSIDERATIONS OF USE:
This source shall be distributed only to specific licensees of the o
NRC or Agreement States.
This source shall be leak tested at six-month intervals using tech-o niques capable of detecting the presence of 0.005 microcurie of
- activity, o
Handling, storage, use, transfer, and disposal: To be determined by the licensing authority.
o Thesourceshallnotbesubjectedtoenvironmentalorothercondi-tions of use which exceed the ANSI N542 Classification of 77C53346.
o This registration sheet and all information contained within the references shall not be changed or transferred without the written consent of the NRC.
SAFETY ANALYSIS
SUMMARY
l Based on our review of the information and test data contained in the references cited below, the claimed ANSI classification whch exceeds the ANSI N542 recommended I
i
CP no REGISTRY OF RADI0 ACTIVE SEALED SOURCES AND DEVICES
-SAFETY EVALUATION OF SEALED SOURCE (Amendedinentirety)
NO:
NR-460-S-106-S DATE:
PAGE 6 0F 7 JUL 11 FM SOURCE TYPE: -Strip Source SAFETY ANALYSIS
SUMMARY
Classification of 77C43232, that this amendment increases only the' maximum activity from 2 curies to 10 curies we continue to conclude that the Model 4F6P source design is acceptable for licensing purposes.
Furthermore, we conclude that this source would be expected to maintain containment integrity for normal research, development and industrial uses.
Additionally, the source would be expected to maintain containment integrity ~
under accident conditions applicable to the uses specified in this certificate.
REFERENCES:
'The following supporting documents for the model 4F6P are hereby incorporated by reference and are made a part of this registry document:
3M letter requesting change of model 4F6P dated April 11, 1984 and all o
enclosures therein.
o This supersedes registration sheet # NR-460-S-106-U dated I
April 29, 1964.
i
)
L
0 i or z
0 00
\\
-REGISTRY OF RADI0 ACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE l
(Amended in entirety) l NO:
NR-460-S-106-5 DATE:
PAGE 7 0F 7 00L 11 EM SOURCE TYPE:
Strip Source ISSUING AGENCY:
USNRC Date:
Reviewer:
A
+42 -
Date: