Text
_
o I
5 4,
f.
The information on this page is considered to be appropriate
.for public disclosure pursuant to 10 CFR 2.790 U. S.
NUCLEAR REGULATORY COMMISSION OFFICE OF NUCLEAR MATERIAL SAFETY AND SAFEGUARDS
' Report Number:
70-36/89-200 License Number:
SNM-33 Priority:
O Category:
ULFF Safeguards Group:
III Licensee:
Combustion Engineering, Inc.
i~
CE Power Systems P. O. Box 107 Highway P Hematite. Missouri 63047 Facility Name:
Combustion Engineering Fuel Fabrication Facility Inspection at:
Hematite, Missouri Inspection Conducted:
May'8 through 12, 1989 Inspector:
O Wl 30/ 87 G. B. NelsM, Chemist, Saf fguards Date signed Section, NMSS Branch, Region V, US NRC
- Approved by:
O%
Gb6m OY3d/89 D. J. Kasunf,/ Section..eader, Physical Date signed Security and MC&A Licensing and Inspection Section, SGDB, SGTR, NMSS Summary Scope:. The inspector conducted a routine unannounced MC&A Safeguards inspection in the areas of measurement systems, records and reports and management meetings, entrance and exit interviews.
Inspection Procedures 85407, 85415 and 30703 were used.
.Results: Within the areas inspected, no violations, deviations or declining performance were identified.