ML20247N778

From kanterella
Jump to navigation Jump to search
Interim Part 21 & Deficiency Rept CP-89-003 Re Cable Assemblies for post-accident Neutron Flux Monitors Supplied by Gamma-Metrics (Gm).Initially Reported on 890215.GM Part 21 Rept Issued.Next Rept Will Be Issued Prior to Fuel Load
ML20247N778
Person / Time
Site: Comanche Peak  
Issue date: 06/02/1989
From: William Cahill, Walker R
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
REF-PT21-89 CP-89-003, CP-89-3, TXX-89361, NUDOCS 8906060024
Download: ML20247N778 (1)


Text

7_

4 ME Log # TXX-89361 C

File # 10110 C

C 903.11

" # ***'R'** "

TllELECTRIC William J. Cahill, Jr.

Executive Vue President U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D. C.

20555

SUBJECT:

COMANCHE PEAK STEAM ELECTRIC STATION (CPSES)

DOCKET NOS. 50-445 AND 50 446 GAMMA-METRICS NEUTRON FLUX MONITORS SDAR:

CP-89-003 (INTERIM REPORT)

Gentlemen:

On February 15, 1989. TU Electric verbally notified the NRC of a deficiency j

involving Gamma-Metrics supplied cable assemblies for post-accident neutron l

flux monitors.

Specifically, Gamma-Metrics has issued a 10CFR21 notification that addresses possible leaks in threads and solder connections of the neutron flux monitor cable assemblies.

This is an interim report of a potentially reportable item under the provisions of 10CFR50.55(e).

Further evaluation of this issue is required to determine potential impact on plant safety. The next report will be issued prior to Unit I fuel load.

Sincerely, Qdtf0'am h. Od h-William J. Cahill, Jr.

By:

Yi 4

Roger D. Walker Manager, Nuclear Licensing f

VPC/ddm c - Mr. R. D. Martin, Region IV l

Resident Inspectors, CPSES (3)

)

8906060024 890602 FDR ADOCK 05000445 S

PDC IQ 400 North Olive Street LB 81 Dallas, Texas 75201

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _ _ _