ML20247M829
| ML20247M829 | |
| Person / Time | |
|---|---|
| Site: | Comanche Peak |
| Issue date: | 05/26/1989 |
| From: | William Cahill, Woodlan D TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC) |
| To: | NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM) |
| References | |
| CP-89-002, CP-89-2, TXX-89294, NUDOCS 8906050162 | |
| Download: ML20247M829 (1) | |
Text
. _ _ _ - _ _ _
i Log # TXX-89294
._rM File # 10110 909.5 i
r.
r Ref. # 10CFR50.55(e) 119 ELECTRIC May 26, 1989 i
uoe ice P derst i
U. S. Nuclear Regulatory Commission Attn: Document Control Desk 1
Washington, D. C.
20555
SUBJECT:
COMANCHE PEAK STEAM ELECTRIC STATION (CPSES)
DOCKET NOS. 50-445 AND 50-446 IMO DELAVAL FUEL INJECTION PUMP SDAR: CP-89-002 (INTERIM REPORT) i Gentlemen:
On January 25,1989,'TU Electric verbally notified the NRC of a potential deficiency involving the IMO Delaval Diesel Generator fuel injection pump.
Our last report on this subject is logged TXX-89092 dated February 24, 1989.
This is an interim report of a potentially reportable item under the provisions of 10CFR50.55(e).
Further evaluation is required to establish the safety significance of the potentially reportable deficiency. The final report (s) will be submitted prior to fuel load for the respective units.
Sincerely, i
William J. Cahill, Jr.
I I
pf W
By:
D. R. Woodlan Docket Licensing Manager MCP/vid c
.Mr. R. D. Martin, Region IV Resident Inspectors, CPSES (3) l 8906050162 890526 PDR ADDCK 05000445 s
PNU I e 400 North Olive Street LB 81 Dallas, Texas 73201 i
- - _ _ _ - _ _ _ _ _ - _ -