'D cf May 25, 1989 EN 89-57 4
i 0FFICE OF ENFORCEMENT!
NOTIFICATION OF SIGNIFICANT ENFORCEMENT ACTION J
Licensee: Niagara of Wisconsin Paper Corporation (EA89-65) q
~
Niagara, Wisconsin Docket No. 99990003
Subject:
PROPOSED IMPOSITION.0F CIVIL. PENALTY - $750 l
' This is to inform the Comission that a Notice of Violation and_ Proposed Imposition of Civil Penalty in the amount of Seven.Hundred Fifty Dollars ($750) will be issued on or about May 31,1989 to Niagara of Wisconsin Paper Corporation, Niagara,. Wisconsin. This action is based on two violations which involved:
(1) failure to have licensed individuals perform the removal of a generally-licensed radioactive gauge from its installed location, and (2) transfer of a radioactive gauge to an' unlicensed metal salvage yard. The base civil penalty amount was increased by 50% because the licensee's corrective actions were not timely.
It should be noted that the licensee has not been specifically informed of the enforcement action. The schedule of issuance and notification is:
Mailing of Notice May 31, 1989-Telephone Notification of Licensee May 31, 1989 The State of Wisconsin will be notified.
The licensee has thirty days from the date of the Notice in which to respond.
Following NRC evaluation of the response, the civil penalty may be remitted, mitigated, or imposed by Order.
Contact:
J. De1 Medico, OE, 20739 J. Lieberman, OE, 20741 Distribution 0WFN 3' T OWFN 3: I MNBB 3 J[
Chairm Hach EDO RM Com. Roberts DEDR AEOD Com. Carr DEDS Com. Rogers OE Com. Curtiss NMSS SECY lip.R ACRS 01 CA SP GPA OGC Regional Offices RI Wi RIV 3:D, MAIL ADM: Doc. Ngt. Br.
RII e i RV
< e is' PDR RIII u r r RES DIG PRELIMINARY INFORMATION - NOT FOR PUBLIC DISCLOSURE UNTIL PUBLICLY ANNOUNCED 8906050150 890525 1p Nh89Mb7 f
PDC Ofl
/ E, 33
_