SPECIFIC REFERENCE MATERIAL LIST FOR SA-109 General IMPEP related documents:
- 1. NMSS Procedure SA-100, Implementation of the Integrated Materials Performance Evaluation Program (IMPEP)
- 2. NMSS Procedure SA-101, Reviewing the Common Performance Indicator, Status of Materials Inspection Program
- 3. NMSS Procedure SA-102, Reviewing the Common Performance Indicator, Technical Quality of Inspections
- 4. NMSS Procedure SA-103, Reviewing the Common Performance Indicator, Technical Staffing and Training
- 5. NMSS Procedure SA-104, Reviewing the Common Performance Indicator, Technical Quality of Licensing Actions
- 6. NMSS Procedure SA-105, Reviewing the Common Performance Indicator, Technical Quality of Incident and Allegation Activities
- 7. NMSS Procedure SA-111, Formal Qualifications for Integrated Materials Performance Evaluation Program (IMPEP) Team Members and Team Leaders
- 8. NMSS Procedure SA-300, Reporting Material Events
- 9. NMSS Procedure SA-400, Management of Allegations
- 10. NRC Management Directive 5.6, Integrated Materials Performance Evaluation Program (IMPEP)
- 11. NRC Management Directive 8.8, Management of Allegations Documents for both operations and closure phases of a LLRW disposal facility:
- 1. NRC Inspection Manual, Inspection Manual Chapter (IMC) 1248, Qualification Programs for Federal and State Materials and Environmental Management Programs
- 2. NRC Inspection Manual, Inspection Manual Chapter (IMC) 2401, Near-Surface Low-Level Radioactive Waste Disposal Facility Inspection Program (Issue date:
November 27, 2001)
- 3. NRC Regulatory Guide 4.15, Quality Assurance for Radiological Monitoring Programs (Inception through Normal Operations to License Termination) - Effluent Streams and the Environment
- 4. NRC Regulatory Guide 4.18, Standard Format and Content of Environmental Reports for Near Surface Disposal of Radioactive Waste
- 5. NRC NUREG-0945, Final Environmental Impact Statement on 10 CFR Part 61:
Licensing Requirements for Land Disposal of Radioactive Waste A-1
- 6. NRC NUREG-1200, Standard Review Plan for the Review of a License Application for a Low-Level Radioactive Waste Disposal Facility
- 7. NRC NUREG-1573, A Performance Assessment Methodology for Low-Level Radioactive Waste Disposal Facilities: Recommendations of NRC's Performance Assessment Working Group
- 8. NRC NUREG-2175, Guidance for Conducting Technical Analyses for 10 CFR Part 61
- 9. Low-Level Radioactive Waste Disposal Information on the NRC Web site https://www.nrc.gov/waste/llw-disposal.html includes, but is not limited to the following documents:
- i.
Branch Technical Position on Concentration Averaging and Encapsulation, dated February 2015, (ADAMS Accession Nos.: ML12254B065, ML12326A611, and ML16096A278) ii.
Interim Guidance on Blending of Low-Level Radioactive Waste, dated March 17, 2011, (ML110480850) iii.
Branch Technical Position on Waste Form, Revision 1, dated January 24, 1991, (ML033630746)
Documents specifically for the operations phase for the LLRW disposal facility:
- 1. NRC Regulatory Guide 4.19, Guidance for Selecting Sites for Near Surface Disposal of Low-Level Radioactive Waste
- 2. NUREG-1199, Rev 2, Standard Format and Content of a License Application for a Low-Level Radioactive Waste Disposal Facility, January 1991
- 3. NUREG-1300, Environmental Standard Review Plan for the Review of a License Application for a Low-Level Radioactive Waste Disposal Facility, April 1987
- 4. NRC NUREG/CR-6567, Low-Level Radioactive Waste Classification, Characterization, and Assessment: Waste Streams and Neutron-Activated Metals Documents specifically for the closure phase of a LLRW disposal facility:
- 1. NUREG-1388, Environmental Monitoring of Low-Level Radioactive Waste Disposal Facility, December 1989
- 2. Site Closure Plan for the LLRW disposal facility
- 3. 10 CFR Part 61.28 Contents of Application for Closure A-2