ML20247H983
| ML20247H983 | |
| Person / Time | |
|---|---|
| Site: | Comanche Peak |
| Issue date: | 05/24/1989 |
| From: | William Cahill, John Marshall TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC) |
| To: | NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM) |
| References | |
| CP-87-07, CP-87-7, TXX-89292, NUDOCS 8905310379 | |
| Download: ML20247H983 (1) | |
Text
_ _ - _ _-
}
g.
4 aNmmer Log # TXX-89292 1
C File ' # 10110 C
Z 917.1 R' # **C'R'***'(
filELECTRIC WlHimm J. Cahid, Jr.
Execuhve Vice President U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D. C.
'20555
SUBJECT:
COMANCHE PEAK STEAM ELECTRIC STATION (CPSES)
DOCKET NOS. 50-445 AND 50-446 ITEMS PROCURED TO IMPROPER CODE CLASS SDAR:
CP-87-07 (SUPPLEMENTAL REPORT)
Gentlemen:
On February 19, 1988, TV Electric's report logged TXX-88168 notified the NRC of a reportable deficiency involving items procured with a 0-code "C" instead of a 0-code "A".
The last report on this issue, logged TXX-88810, was submitted on December 9, 1988. This supplemental report is submitted to update.the corrective action completion schedule.
Unit 1 corrective actions for this issue have been rescheduled for completion
(-
by Unit I fuel load. The Unit 2 corrective action completion schedule remains unchanged.
Sincerely, l
William J. Cahill, Jr.
I By*
(. S. Marshall Generic Licensing Manager DAR/vid c - Mr. R. D. Martin, Region IV Resident Inspectors, CPSES (3) k
[-
[1 ADO g
0 400 North Olive Street LB81 Dallas, Texas 75201
- - _ - - _.