ML20247H786

From kanterella
Jump to navigation Jump to search
Application for Renewal of QA Program Approval for Radioactive Matl package:0128.Fee Paid
ML20247H786
Person / Time
Site: 07100128
Issue date: 09/01/1989
From: Citek F
AMOCO OIL CO.
To: Macdonald C
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
References
25909, NUDOCS 8909200094
Download: ML20247H786 (7)


Text

+ __

g RETUn,h,TO mo g

- 7/_ dg8 as

=,

Amoco Oil Company L

'y Whiting Refinery

</

Whi ing. Ind an 43 N

219-473-7700 g

py Frank J. Citek v

nefmey an.n.g.,

USNRc SLLill4 1

S89 }

0

?

September 1, 1989 Eh y Ucza;;,

,/,

dh.

s

/.

Mr. Charles W. HacDonald, Chief

'Q gx Transportation Branch DWG Division of Safeguards and Transportation, NMSS United States Regulatory Commission Washington, D. C. 20555

Dear Sir:

We wish to renew our current Quality Assurance Program Approval Certificate Number 0128 which expires on September 30, 1989.

Except for the changes in the attached Company Table of Organization indicating the current chain of responsibility, our Quality Assurance Program will continue to be maintained and executed as required by 10 CFR Part 71 to return (ship) packages of radioactive materials back to the original supplier.

Our written Operating and Emergency Procedures require us to use industrial radiography as a tool to assure safe conditions of refinery equipment and to comply with all NRC regulations governing industrial radiography.

M. M. Shendrick, Chief Inspector on Special Assignment, is Radiation Safety Officer'(RS0) and has the responsibility for the Radiation Safety Program as authorized by NRC License No. 13-00155-10.

A license amendment application submitted August 17, 1989 to the NRC Region III Office (Control No. 87846) is pending with a request to approve M. J. Berna, Chief Inspector, to replace M. M. Shendrick, who is retiring at the end of the year.

All required material and personnel records, manufacturer certificate files, reminders, notices and communications pertaining to radiation safety and equipment are the responsibility of Administrative Assistant Shirley Manning. There are written instructions to

. Storehouse Receiving personnel to notify the RSO immediately upon

/j receipt of any radioactive material. A radiographer is quickly sent to examine the container, determine the maximum stray radiation levels

}($3 at the required distances from the container, record the radiation ___ _

level readings on a copy of the shipping papers and forward this Jey-H-/

documentation to Mrs. Manning.

YB & Y 7/ rd 8909200094 890901 y

ADOCK0710g8 PDR 3

c

/ha og l

1

- _ _ - _ _ = _ _ _ _ - _ _ _

"i. Charles W. MacDonald, Chief Page 2 The individual radiographic sources'that are currently used at our facility are purchased-from Amersham Corporation (formerly Technical Operdions Inc.), holders of NRC Quality. Assurance Program Approval No. 0040. All new replacement sources are shipped to us in NRC and D0T approved containers certified for safe handling of the strongest I

sources that we obtain (see attachments).

-Our Operating and Emergency Procedures detail the step-by-step procedures for changing sources and servicing the supplier's containers.- The container with the weaker source is sealed, radiation

-levels measured and recorded, necessary shipping 1abels attached and shipping papers prepared. Only then is the container shipped back to the source supplier via NRC approved carriers. Source supplier sends a receipt acknowledging return of our weak sources. All handling and monitoring of the sources is performed by a trained and qualified radiographer under the direction of the RSO. Records of receipts, surveys, tests, source inventories and disposals are maintained by Shirley Manning for-periods of time per NRC regulations. Our Radiation Safety Program is monitored quarterly and audited annually by the RSO.

Accompanying this renewal application is a check for $150.00, a fee pursuant to 10CFR Part-170.31.

Yours truly, O, <

'w F. J. Citek Attachments

)

cc: James Keppler, Region III

AM000 OIL COMPANY 2815 Indianapolis Blvd.

Whiting,. Indiana 46394 o

Names and Addresses of Refinery Management (Pending Approval of NRC Control No. 87846)

F. J. Citek Refinery Manager

.2815 Indianapolis Blvd.

Whiting, Indiana 46394 J. C. Koller Manager - Refinery Services 2815 Indianapolis Blvd.

Whiting, Indiana 46394 J. E. Casebolt

' Manager -

2815 Indianapolis Blvd.

. Technical Services Whiting, Indiana 46394' D. L..McKeehan Manager -

2815 Indianapolis Blvd.

Engineering Projects Whiting, Indiana 46394 S. W. Savage Supervisor -

2815-Indianapolis Blvd.

Inspection Services Whiting, Indiana 46394 M. J.- Berna Chief Inspector.-

2815 Indianapolis Blvd.

Inspection Services Whiting, Indiana 46394 J. J. Ardner Engineer - Codes, 2815 Indianapolis Blvd.

Specifications, State Law Whiting, Indiana 46394

. P. Zemen Safety Specialist 2815 Indianapolis Blvd.

Plant Security Whiting, Indiana 46394 l~

l 1

lI c-

37

, y numxuwcvcwn

- - - - - - - - - - ~ - -

~

J Fr:

'.. c%.i. oc e.,,,

l, p;. sa;: c. vme:>,un m ost:.v 9'

l

'lau-phent il 171777 8DX-l 1

I 1

1 l

l June 22, 1989 l

Dear Customer:

Amersham Corporation applied for renewal ~of U.S. Nuclear i

Regulatory Commission Certificates of Compliance for.the model 660 exposure device; USA /9033/B(U) and the model 650 source-changer; USA /9032/B(U) in March 1989.

The model 660 certificate expired on 31 May 1989 and the 650 certificate expires on 30 June 1989.

)

1 Both certificates are still in effect under timely renewal while;the renewal applications are reviewed by the NRC.

You may continue to ship both of these packages under the timely renewal.

New certificates will be sent when they are j

received.

l Please contact Amersham if you have any questions.

Sincerely.

l b L'O OY $1 l

Cathleen M. Roughan Radiation Safety Officer CMR3/sp f

l timersyam

,a

V

\\

US Deponrnent Of ironspor!O?On e x s,,,,,

3,,,,. 3 osveston DC W 9.

Research and Specnol Programs

  • I COMPETENT AUTHORITY CERTIFICATION FOR A TYPE B(U)

RADIOACTIVE MATERIALS PACKAGE DESIGN CERTIFICATE USA /9033/B(D), REVISION 3 This certifies that the radioactive materials package design described below has been certified by the competent authority of the United States as meeting the regulatory requirements for a Type B{U) packaging fo materla as prescribed in the International Atomic Energy Agency { radioactiveandUSAregulations.gs 1.

Packace Identification - Amersham Model Nos. 660 and 660E.

2.

Packacing Description and Authorized Radioactive Contents as described in Nuclear Regulatory Commission Certificate of Compliance No. 9033, Revision 5 (attached).

3.

GENERAL CONDITIONS -

a.

Each user of this certificate must have in his possession a copy of this certificate and all documents necessary to properly prepare the package for transportation.

b.

Each user of this certificate, other than the original petitioner, shall register his identity in writing to the Office of Hazardous Materials Transportation, Research and Special Programs Administration,

U.S.

Department of Transportation, Washington D.C. 20590.

c.

This certificate does not relieve any consignor or carrier from compliance with any requirement of the Government of any country through or into which the package is to be transported.

1

" Safety Series No. 6, Regulations for the Safe Transport of Radioactive F,aterials, 1973 Revised Edition" published by the International Atomic Energy Agency (IAEA), Vienna, Austria.

2 Title 49, Code of federal Regulations, Parts 100 - 199, USA.

h

~.

I i

(- 8 -)

CERTIFICATE USA /9033/B(D), REVISION 3 I

d.

This certificate is issued only to authorize transport from i

point of entry to final destination within the bnated States and from point of origin in the United States to point of exit.

4.

Marking and Labeling The package shall bear the marking USA /9033/B(U) in addition to other required markings and labeling.

5.

Expiration Date - This certificate expires on November 30, 1989.

This certificate supercedes, in its entirety, all previously issued revisions of USA /9033/B(U)+

This certificate is issued in accordance with paragraph 806 of the IAEA Regulations and Section 173.471 of Title 49 of the Code of Federal Regulations, and in response to the May 5,

1989 petition by Amersham Corporation, Arlington Heights, IL, and in consideration of the associated information therein.

Certified by:

hggd MAY l 81989 Michhel E. Wangler (7/

(DATE)

Chief, Radioactive Materials Branch Office of Hazardous Materials Transportation Revision 3 - Issued to extend the expiration date.'

h ec eoe su rs...

CERTIFICATE OF COMPLIANCE o s Nuctt AR atcut Atcm couu:ssem f

..t ' S ' '.

i FOR RADIOACTIVE MATERIALS PACK AGES l

'i.

I at.+v wer i ' 5 ';i'c'ia'a'ca'

}

e cr,.c.n wi,n s~~

.*.t. we.o

,, ca., ~ e s..

9033 5

USA /9033/B(U) 1 2

$: C H e v6. t l

a it..t te'hiet sie es iss.ec to Ce'i, tha' tne pac sa p.ng one t cmients yest eet*O m firm $ twe'ow meets tr t spo'. tat se se*ri, stanceeas sei torte..n 1. tic '.C Cose e

y os s coeve kepstanons Pa.i 7i

  • >ec sepep o' Aas oet tive Maie.. sis to,1sanspues eno t eenspoensi.o' b' 85a3 wachve Mater *at Unce Certa.r. Cono.nons

$5, in.s teen hceir o es not ee6.e.e the cons.pno. hom comphance with any sees.'ement o' the sepstai.uas oe U s Depa tment of transpo,isi.on c ome.

t

{8) appe.t.a0*e eepuistory agent es meagemg IM po.ernr,ent of any country theo..g s o. mio which the C,acaspe..si tie tearisportec i8)

N

?!, i.,3 ce,

.c.n, deveme s*0.o mi.. sis or. 5..t i,.~ ro, ni coai or mi e.c..ci of 5.c.~ o..r.:c...o,.

5 issut o

'3 e Ps*I e.ht D B co ean s

t. Tait!.6dD IDE N18' 6C.isoN o' sit s Ont om app.sc.1 o~

40c Tech / Ops Tech / Ops application dated November 8,1974, jc 40 North Avenue as supplemented.

's Burlington, MA 01803 e

.'t ea 71-9033

, occats wem a C($NDilloN5 Thes cert <ticale es concational upon tuttdienp the reavarements of 10 CF A Part 71. 35 applicable and the concibons spetsf ec below v

.s t Q

(a)

Pa ckagi ng ij (1) Model Nos.:

660 and 660E eqj (2)

Description 0

Q's!

A steel encased, uranium shielded Gamne Ray Projector.

Primary components consist of an outer steel shell, polyurethane potting reterial, uranium shield, "5* tube, and end plugs.

The contents are securely positioned l

t in the "S" tube by a source cable locking device and shipping plug.

y Tamper-proof seals are provided on the packaging.

The maxinJn total

,j weight of the package is approximately 48 pounds.

't (3)

Drawings i'

'?

The packaging is constructed in accordance 'with the Technical Operations, y

Inc. Drawing No. 66025, Sheets 1, 2, and 3, Rev. B and Sheet 4, Rev.

l 2

E (b)

Contents 9

j (1)

Type and form of reterial w)

Iridium 192 sources which meet the requirements of special forn radioactist

5 material.

bi y

(2) Maximum quantity of material per package p

h 120 curies N

f i

h50

,4 i'

h hM l.

+ ~s e,m

.~e~e

~r.-~~.*x ----"~"~~*'**-x

  • au ^* E d*.t A Y

~*

c conomous uc,,,,,.,cc, 1}.;

~ Page 2 - Certificate No. 9033 - Revision. No. 5 - Docket No. 71-9033 i

i 6.

' The source assembly for use with this packaging is -limited to Technical Opera-tions..Inc. Model No. A424-9 as shown in Technical Operations, Inc. Drawing tio.

j C42400, Sheet 2'of 3, Rev. F.

i 7.

The name plate nust be fabricated of materials capable of resisting the fire i

test of 10 CFR Part 71 and maintaining their legibility.

i 8.

..The package authorized by th'is certificate is hereby approved for use' under general license provisions of 10 CFR 571.12.

L 9.

Expiration date:

May 31, 1989.

REFERENCES

'Te' chnical Operations, Inc. application dated November 8,1974.

Supplements dated:

December 15,1978; June 15,1979; and April 17, 1984 FOR THE U.S. NUCLEAR REGULATORY COMlllSS10tl

$k%

Charles E. MacDonald, Chief Transportation Certification Branch l

Division of fuel Cycle and Material Saf ety, it:55 U

1W l

Date-I

!~

l l

i I

i l

)

l I

1 i

5 l

i

)

L

-n_

  • 1 r: 'td d.Y. ci F> R"

@e w$b)

I p @s s fi

@f 3,rgg' 9 e

,M

!l!

pti o

g iL Ev 3 O

' /'

51 DE

( -d. e9

?.y e

r s gE t o r 1

g 5

f0 h z

se

.25<

4 Y?

0 b

w:. n /,

as ac

'ig' Y s

3h,

* o i.

G

, 01

{$

t:E 0i n

@e

.a)

V go

,' ' "' % k jN '

s i

o mies NN N

i g en g h *]Z l

ti n i Ofpf l

p

>@- }4 W SB i

?

ese;

- p')s c

g i

og f33 a

/

N o

2 em Bo o

gw sX eg r"

-g

._, g 5ccgg Bc j

r i

>s t

y g

8

'L: 'NO i.

' s%

h' s

e x

hi ea s s o

d e,

y

[

t

'I,

eo ii h

U u

i tj N

L2 M

-4_

h.$

e g

l\\

\\g \\

Wi g

~

1 me i

? N ss 2

1

(

N i s

\\

92 i

\\

~N m

e s

s u

e k~

\\

N

\\

b s

e a

4 s

4 N

N 5

g h$,

$" 5 g

N

^

N

'b ]

Ns f,

g cu s

a s

' m w

e dwu s

'\\s s

Ob$

h

, \\

\\

\\

\\

s

_, o N

\\ \\

N E

$f. N

\\

s 'N" s\\

x e

x

/

e>

m a%s h

8 L

f-s'

,g g e-

, -Nm agA

,gx i.

m gi, s

\\

h

L,

,. ao US Department

'UU 6"""" S' S*

CORRECTED COPY M5hington. D c" 20!,90 Ofiron5portation Research and ~

. Special Programs IAEA CERTIFICATE OF COMPETERT AUTHORITY

. Administration SPECIAL FORM RADI0 ACTIVE MATERIALS CERTIFICATE NUMBER USA /0335/S, REVISION 1 This certifies that the source described has been demonstrated to meet the regulatory requirements for special fgtm radioactive material as prescribed in IAEA Regulations and USA regulations for the transport of radioactive materials.

1.

Source Description - The source described by this certificate is identified as Amersham Model 875 source capsule assembly which is a single welded encapsulation constructed of Type 304 or 304L stainless steel, and measures approximately 24 mm (0.95") in length by 6.4 mm (0.25") in diameter. Contents may be further contained in stainless steel or titanium inner secondary encapsulations with springs and spacers.

2.

Radioactive Contents - This source consists of not more than 8.88 TBq (240 Ci) Iridium 192 as solid metal, 8.14 TBq (220 Ci) Cobalt 60 as solid metal, 7.4 TBq (200 Ci) Ytterbium 169 as Yb 0,1.11 23 TBq (30 Ci) Cesium 137 as CsC12 in a secondary stainless steel encapsulation, or 1.85 TBq (50 C1) Thulium 170 as Tm2 3 0

t 3.

Expirat ion Date - This certificate expires July 15, 1994.

This certificate is issued.in accordance with paragraph 803 of the IAEA Regulations and Section 173.476 of Title 49 of the Code of Federal Regulations, and in response to the June 14, 1989 petition by Amersham Corporation, Burlington, MA, and in consideration of the associated information therein, and other information filed with this office.

Certified by:

JU' - 5 S39

  • /

Nichhel E. Wanglef (DATE)

Chief, Radioactive Material. Branch Office of Uszardous Ibterials Transportation Revision 1 - Issued to change the cource identification from Tech Ops to Amersham and to extend the expiration date.

I " Safety Series No. 6, Regulations for the Safe Transport of Radioactive Materials,1973 Revised Edition" published by the International Atomic Energy Agency (IAEA), Vienna, Austria.

2 Title 49, Code of Federal Regulations, Parts 100 - 199, USA.

.