ML20247H335

From kanterella
Jump to navigation Jump to search
Mod 8 to Contract NRC-04-94-036
ML20247H335
Person / Time
Issue date: 04/30/1998
From: Gest C, Mace M
NRC OFFICE OF ADMINISTRATION (ADM), WISCONSIN, UNIV. OF, MADISON, WI
To:
References
CON-FIN-W-6183, CON-NRC-04-94-036, CON-NRC-4-94-36 NUDOCS 9805210137
Download: ML20247H335 (4)


Text

1 e

e OCD AMENDMENT OF SOLICITATION / MODIFICATION OF CONTRACT

'['

9 03 2

2 CMENDMEN1rMOOiHCAf TON NO J EtH CTIVE DATE

! 4 MOUiStilON PURCHASE RCO NO RES-C98-406 6 PROxCT No. nr oppi.catm APR 3 01998 REs-C98 051 M008 s Isstan av 7 ADu.NisTEREo ev en ome, men noen ei l

cgg, C0o U.S. Nuclear Regulatory Corrrnission j

Division of Contracts & Property Mgmt.

l Contract Management Branch 1 Mall Stop T-7 I-2 Washington DC 20555 i

8 NAME AND ADDRESS OF CONTRACTOR (No, stves t. couniv. siete end ZIP Codel (xj 9A AMENDMENT OF sOUCITATION NO.

i I

se oATEo tsEE iTEu 11:

Board of Regents of the University of Wisconsin System Attn: Ms. Cheryl E. Gest, Admin Officer 10A. MODinC ATION OF CONTRACT / ORDER NO.

750 University Avenue Medicon WI 53706-1490 Con # NRC-04-94 036 10e DATED (SEE ITEM 13)

-. X 04 26-1994 Coca r ACiuiy CODE

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

] The above numbered sohcitation is amended as set forth an item 14. The hour and date specified for receipt of Offers]is extended.

is not extended.

Offers must acknowledge receipt of this amendmerit pnor to the hour and date specified in the solicitation of as amended. by one of the following methods:

10) By completing items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment of each copy of the offer submitted, or (c) By separate letter or telegram which includes a referesice to the solicitation and amendment numbers. FAILURE OF YOUR AC-KNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECElPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by vtriue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter provided each telegram or letter makes reference to the solicitation and this amendment, and as received pnor to the opening hour cnd d mapecified 12 ccCCWTING AND APPROBATION DAT A iH sews &di B&R No. 86015211025; Job Code W6183; BoC No. 252A

... _ _. AppnJodiXQ200,660 Amoun10Dlisated_55.Q,000,0Q

.. _ _.. _13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS / ORDERS, IT MODIFIES THE CONTRACT / ORDER NO.._AS DESCRI. BED IN ITEM 14.

{x)

& THis CHANGE ORDER is IS%ED PUNSuANT To hi.. uihoravi THE CHANGES 54 Y FORTH IN ITEM 14 AHE MADE IN THE CONTRACT ORDER NO N ITEM 10A so changes in povisig ott.co. approp ieleon date. etc.)

B THE AaOVE NUMBf HED CONTRACT ONDEH IS MODWitD 10 8tEFLECt THE ADMINISTRATIVE CHANGES mucn SET FORTH IN ITEM u PUR$UANT TO THE AUTHOR 11Y OF i AH 41103t6 C. THis sVPPLEMf NT AL AGREEMINT 15 ENTEM D INTO PUNSUANT TO AuTHOsuTV Of j

x ey mutual agreement of the parties.

o OTHER isoec,., L,.m,.~, a u, ie E. IMPORTANT: contr actor is nOt. ; x is required to sign this document and return 2 copies to the issuing of fice.

10 C3sCRIPTION OF AMENDUENr MODet.CA fiON FOrgerwied tav UCF metteon heedings includary selecdelion< convect nutiect mettes where tessate.e )

Please see the attached page.

' ~ 4.g

\\

I C-Encept ca provided herman en teeme og condibons of the dusurnani <Cerenced m item ifA os 10A. e6 heretofure changeo sorr.e.ns usuhenged esto en full loste and effect 16A NAME ANO Iffli OF CONTRACTING OHICER 11ype or prend Isa NOME AND TITEE OF SIGNt >

T,p os pne t Cheryl E. Geste Admin. Officer mary s. mace Contracting Officer Research & Sponso, red Programs 1% DA i t uGNE D its uni 1 EV 5 A T E 5 0f AMEN A

)

16C DAff s#GNED

(

160 CONT OH E ROa 4

e-e,,gne. eW.~&.

w /

/ww

/ > /ww

, m,.@d, J i

/ ~ p e. Ceneen,3 On.u

(/j.'>. [-

zn.

^

9805210137 980430 si ANoA,io u>..e ao iRev io esi m.mmv,R PDR CONT_uw r.m

Contract No. NRC-04-94-036 l

Modification No.

8 Page 2 of 2 l

The purpose of this modification is to (1) provide within scope changes which shall be performed in accordance with the attached Statements of Work and the contractor's technical proposals dated 04/06/98 and 04/27/98. (2) increase the contract ceiling and obligated amounts by $50.000 from 5436.940 to $486.940, and (3) extend tne period of perforniance through December 31. 1998.

1.

The attached Statements of Work are hereby incorporated as part of Section C.1 of the contract.

2.

Under Section B.3. Consideration and Obligation--Cost Reimbursement (JUN 1988). Alternate I. (JUN 1988) paragraphs (a) and (b) are deleted in their entirety and the following paragraphs are substituted in lieu thereof:

"(a) The total estimated cost to the Government for full performance under this contract is $486.940."

1 (b) The amount presently obligated by the Government with respect to this contract is $486.940."

3.

Section F.6. Duration of Contract Period is deleted in its entirety and the following is substituted in lieu thereof:

"This contract shall commence on 04/26/94 and will expire on 12/31/98."

A summary of obligations for this contract. from award date through the date of this action. are given below:

Total FY94 Obligation Amount:

5136.000.00 Total FY95 Obhgation Amount :

5135.940.00 Total FY96 Obligation Amount:

i 75.000.00 Total FY97 Obligation Amount:

$ 90.000.00 Total FY98 Obligation Amount:

5 50.000.00 Cumulative Total NRC Obligation Amount:

1486.940.00 l

l This modification obligates FY97 tunds in the amount of $50.000.00."

x All other terms and conditions of the subject contract remain unchanged.

t l

j l

l

)

DESCRIPTION / SPECIFICATIONS / WORK STATEMENT MODIFICATION C.3 SCOPE OF WORK Task 1: WFCI Experiments s

Terminate the conduct of further iron oxide FCI experiments and report the results of experiments conducted thus far (both iron oxide and tin simulants) in a NUREG/CR report.

The termination is necessitated due to a budget cut.

Task 5: Technical Assistance to NRC Present the ;esearch findings from the iron oxide FCI experiments at the CSARP meeting in May 1998.

Revise the completion dates of the existing open tasks as follows:

Tast Dale Revised Date 1 (WFCI Experiments) 04/30/98 10/31/98 3 (NRC Support for KROT05 and FARG) 04/30/98 10/31/98 5 (Technical Assistance to NRC) 04/30/98 10/31/98 (Tasks 2 and 4 have been completed.)

Revise the existing deliverable schedule as follows:

Deliverable Qate Revised Date Draft NUREG/CR report (Task 1) 02/28/98 08/31/98 Final NUREG/CR report (Task 1) 04/30/98 10/31/98 4

DESCRIPTION / SPECIFICATIONS / WORK STATEMENT MODIFICATION C.3 SCOPE OF WORK Add the following task to the contract:

Task 6: IFCI Assessment The recently completed peer reviewof the integrated fuel-coolant interaction code, IFCI, identified a number of areas in which further improvements were warranted. Sandia National Laboratories (SNL), the developer of IFCI, has since modified the code incorporating improvements in some of the identified areas. It is now necessary to perform an assessment of IFCI to determine how the overall predictive capability of IFCI has improved. The contractor shall perform an assessment of IFCI against a set of 10 experiments selected from the following matrix and approved by the NRC Project Manager:

FARO quenching experiments L-14, L-20, L-28 KROTOS steam explosion experiments K-21. K-26, K-42 K-52 WFCl steam explosion experiments WFCl-D4, WFCl-H3, WFCl-H4 ZREX chemical augmentation experiments ZREX-19, ZREX-20, ZREX-34, ZRSS-10 The set of 10 experiments shall be so selected as to allow an assessment of the major modeling features in IFCl. These include: mixing, jet and particle breakup, quenching, oxidation and hydrogen generation, and shock wave propagation. The contractor shall also prepare an assessment report documenting the work under this task.

Estimated completion date:

12/31/98 Estimated level of effort:

6.0 staff-months Add the following deliverable in the schedule:

Deliverable

_Date IFCI assessment report (Task 6) 12/31/98 x