Agg%,, i North Nonh Adantic Energy Service Corporation P.O. Box 300 Atlantic se broek.si103874 0

(603) 474-9521 The Northeast Utilities System May 15,1998 Docket No. 50-443 NYN-98064 United States Nuclear Regulatory Commission Attention: Document Control Desk Washington, D.C. 20555 Seabrook Station Steam Generators Inservice Insnection North Atlantic Energy Service Corporation (North Atlantic) has enclosed pursuant to Seabrook Station Technical Specification Surveillance Requirement 4.4.5.5b, a report documenting the results of inservice inspections conducted on the Steam Generators during the fifth refueling outage which occurred in May/ June 1997.

Should you have any questions regarding this matter, please contact Mr. Terry L. Ilarpster, Director ofI.icensing Services (603) 773-7765.

Very truly yours, NORTH ATLANTIC ENERGY SERVICE CORP.

)

)

1%

William A. DiPro o Station Director cc:

11. J. Miller, NRC Region I Administrator C. W. Smith, NRC Project Manager, Project Directorate 1-3 R. K. Lorson, NRC Senior Resident Inspector 9905210123 990515 PDR ADOCK 05000443 l

0 PDR

[