Deficiency Rept CP-88-38 Re Steam Generator power-operated Relief Valve Capacity in Analysis of Design Basis Steam Generator Tube Rupture Event Presented in Chapter 15 of Fsar.Corrective Action Implementation Schedule Revised
ML20247F836
Person / Time
Site: Comanche Peak  
Issue date: 03/31/1989
From: William Cahill, Walker R
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
CP-88-38, TXX-89159, NUDOCS 8904040056
Download: ML20247F836 (1)


Text

- _ _ _ _ _

p p

.=

M Log # TXX-89159 Fi1e # 10110-

~~

C' C

915.6 7UELECTR/C Ref. # 10CFR50.55(e)

March 31, 1989 W. J. Cahm Es,rutive Vke President U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D. C.

20555

SUBJECT:

' COMANCHE' PEAK STEAM ELECTRIC STATION (CPSES)

. DOCKET N05. 50-445 AND 50-446 SG RELIEF VALVE CAPACITY - SGTR SDAR: CP-88-38 Gentlemen:

On December 14, 1988 TV Electric notified the NRC via report logged TXX-88844 of a deficiency involving the steam generator power operated relief valve capacity in the analysis of the design basis steam generator tube rupture event presented in Chapter 15 of the FSAR.

The purpose of this report is'to revise the corrective action implementation schedule for this. item.

Corrective action implementation is anticipated to be complete and available for your review by' June 30, 1989.

Sincerely, QLlh ' k' William J. Cahill, Jr.

By:

  1. 97 h Roger'D. Walker Manager, Nuclear Licensing JDS/vid c - Mr. R. D. Martin, Region IV Resident inspectors, CPSES (3) 9 71 t O 8904040056.890 PDR ADOCK

$ S-

_ Lycin l'

4(X) North Olive Street LB 81 Dallas, Texas 7201

. - _ _ _ _ _ _ - _ _