Amend 53 to License NPF-38,correcting Terminology of Control Room Isolation for Toxic Gas Protection
ML20247F728
Person / Time
Site: Waterford 
Issue date: 03/23/1989
From: Calvo J
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20247F733 List:
References
NUDOCS 8904040016
Download: ML20247F728 (5)


Text

- _ _ _ _ _ _ _ _ _ _ _ - _ - _ _ _ _ _ _

/p * *

  • cno s

UNITED STATES

! "%, < #,j NUCLEAR REGULATORY COMMISSION

/%"

i WASHINGTON. D. C. 20555 k.'.d /

LOUISIANA POWER AND LIGHT COMPANY DOCKET NO. 50-382 WATERFCRD.STEAli ELECTRIC STATION, UNIT 3 AMENDPENT TC FACILITY OPERATING LICENSE Amendment No. 53 License No. NPF-38 1.

The Nuclear Regulatory Comission (the Commission) has found that:

A.

The epplicaticn for amendmt.nt by Lcuisiana Power and Light Company (the licensee) dated Decen.ber 23, 1988, ccnpiles with the stondorcs and requiretrents of the Atomic Energy Act of 1954, as amended (the Act), and the Cornmission's rules and regulations set forth in 10 CFR Chapter I; B.

The fecility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Corcmission; C.

There is reasonable assurance (1) that the activities authorized by this amendment can be ccnducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Connission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendtnent is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

i l

890404o016 890323 ADOCK0500g2 DR i

. 2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license arrendment, and paragraph 2.C(2) of Facility Operating License No.

hPF-36 is hereby amended tu reed us follcws:

(2) Technical Specifications and Environr.. ental Protection Plan The Technical Specifications.containea in Appendix A, as revised through Amendment No.53, and the Environmental Protectior. Plan conteir.ed in Appendix B, are hereby incorporated in the license.

The licensee stall operate the facility in accordance with the Technical Specifications ano the Envirortrental Protection Plan.

3.

Ttis license amendment is effective as of its date of issuance.

l FOR THE NUCLEAR REGULATORY COMMISSIOh' l

V

'd (d:e i

/m Jose A. Calvo, Director Project Directorate - IV Division cf F.eactor Projects - III, IV, V and Special Projects Office of Nuclear Reactor Regulation

]

Attachment:

Changes to the Technical Specifications Date of Issuance:

March 23, 1989 i

l

~.

t ATTACHMENT TO LICENSE AMENDMENT NO. 53 1

TO FACILITY OPERATING LICENSE NO. NPF-38 DOCKET NO. 50-382 Replace the following pages of the Appendix A Technical Specifications with the attached pages. The revised pages are identified by Amendment number and contain vertical lines indicating the areas of change.

Remove Insert 3-47*

3/4 3/47 3/4 3-48a 3/4 3-48a l

s l

l l

l

  • Page 3-47 was incorrectly numbered by Amendment No. 21; it should have been numbered 3/4 3-47.

l

{

1 INSTRUMENTATION CHEMICAL DETECTION SYSTEMS CHLORINE DETECTION SYSTEM LIMITING CONDITION FOR OPERATION 3.3.3.7.1 Two independent chlorine detection systems, with their alarm / trip setpoints adjusted to actuate at a chlorine concentration of less than or equal to 3 ppm, shall be OPERABLE.

APPLICABILITY:

All MODES.

ACTION:

With one chlorine detection system inoperable, restore the a.

inoperable detection system to OPERABLE status within 7 days or within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> initiate and maintain operation of the control room ventilation system in the isolate n:3de of l

operation.

b.

With no chlorine detection system OPERABLE, within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> initiate and maintain operation of the control room ventilation system in the isolate mode of operation.

l The provisions of Specification 3.0.4 are not applicable.

c.

SURVEILLANCE REQUIREMENTS 4.3.3.7.1 Each chlorine detection system shall be demonstrated OPERABLE by performance of a CHANNEL CHECK at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and a CHANNEL CALIBRATION at least once per 31 days.

WATERFORD - UNIT 3 3/4 3-47 AMENDMENT NO. 21,53

t INSTRUMENTATION CHEMICAL DETECTION SYSTEMS t

BRDAD RANGE GAS DETECTION LIF'ITING CONDITION FOR OPERATION 3.3.3.7.3 Two independent broad range gas detection systems shall be operable with their alarm / trip setpoints adjusted to actuate at the lowest achievable IDLH gas concentration level of detectable toxic gases

  • providing reliable operation.

APPLICABILITY:

All MODES.

ACTION:

With one broad range gas detection system inoperable, restore the a.

l inoperable detection system to OPERABLE status within 7 days or within l

the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> initiate and maintain operation of the control room ventilation system in the isoiate mode of operation.

l b.

With no broad range gas detection system OPERABLE, within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> s

initiate and maintain operation of the control room ventilation system in the isolate mode of operation.

l i

The provisions of Specification 3.0.4 are not applicable.

c.

i SURVEILLANCE REQUIREMENTS 4.3.3.7.3 Each broad range gas detection system shall be demonstrated OPERABLE by performance of a CHANNEL CHECK at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />, a CHANNEL FUNCTIONAL TEST at least once per 31 days and a channel calibration at least once per 7 days.

Calibration will consist of the introduction of a standard gas and adjusting the instrument sensitivity based on the calibration gas i

relationship of the standard gas to the calibrating gas l

l l

l l

  • Including Ammonia WATERFORD - UNIT 3 3/4 3-48a AMENDMENT No. 25,53