_ _.

l-Georgia Power Company fost Office Box 282 Waynesboro, Georgia 30830 Telephone 4 554 9 1 Fost Off c B 262 Birmingham, Alabama 35202 Telephone 205 870-6011 VOgtle Project March 22,1989 United States Nuclear Regulatory Commission ATTN: Document Control Desk File:

X7BC35 Washington, D. C. 20555 Log: GN-1585 PLANT V0GTLE - UNIT 2 NRC DOCKET NUf1BER 50-425 OPERATING LICENSING NUff"2R NPF-79 EVALUATION OF PRESSURIZER SURGE LINE THERMAL STRATIFICATION Gentlemen:

Georgia Power Company hereby submits for NRC review:

1.

5 copies of IICAP-12218 entitled," Evaluation of Thermal Stratification for the Alvin W. Vegtle Unit 2 Pressurizer Surge Line" (Proprietary).

2.

5 copies of WCAP-12219 entitled,

" Evaluation of Thermal Stratification for the Alvin W.Vogtle Unit 2 Pressurizer Surge Line" (Non-Proprietary).

Also enclosed is a Westinghouse authorization letter, CAW-89-046, Proprietary Information Notice, and accompanying Affidavit.

These reports present the methods, data, analysis and qualification results for the Vogtle Unit 2 pressurizer surge line, including thermal stratification.

It has been concluded, based on the current understanding of the thermal stratification phenomenon, that thermal stratification has very limited impact on integrity of the pressurizer surge line of Vogtle Unit 2.

The analysis also concludes that the forty year design life of the plant is not impacted.

As item 1 contains information proprietary to Westinghouse Electric Corporation, it is supported by an affidavit signed by Westinghouse, the owner of the information.

The affidavit sets forth the basis on which the information may be withheld from public disclosure by the Commission and addresses with specificity the considerations listed in paragraph (b) (4) of Section 2.790 of the Commission's regulations.

Accordingly, it is respectfully requested that the information which is proprietary to Westinghouse be withheld from public disclosure in accordance with 10CFR Scr. tion 2.790 of the Commission's regulations.

floN PROP - P0 R gpot 8904030195 890322 b5 f[

l PDR ADOCK 05000425

\\-.

--l? --

File: X7BC35 Log:

GN-1585 March 22, 1989-Page Two Correspondence with respect to the proprietary aspects of the l

Application for Withholding or the supporting Westinghouse Affidavit should reference CAW-89-046 and should be addressed to R. A. Wiesemann, Manager of Regulatory & Legislative Affairs, Westinghouse Electric Corporation, P. O. Box 355, Pittsburgh, Pennsylvania 15230-0355.

Should you require any additional information, please contract this office.

Sincerely,

. k.

J. A. Bailey Project Licensing Manager JAB /PG:pwh Enclosures xc: NRC Regional Administrator NRC Resident Inspector P. D. Rice J. P. Kane R. A. Thomas B. W. Churchill, Esquire J. E. Joiner, Esquire J. B. Hopkins (2)

G. Bockhold, Jr.

R. J. Goddard, Esquire R. W. McManus Vogtle Project File i

]