R E T U R N T o 3 9g,g g W

r, BR $

,i

.J Document Control HF:89:0129 R

y March 16, 1989

\\p DOCKETED g

WVDP OSR, Volume VI USNac g

p MAR 2 91989 )&

SU WuefE 889 )

i NMss EOMMIS o UIONY MAIL SECTton Msg

,3 Q.

DOCKET Cling

/

&yl#"Ibn (r

Controlled Distributi

/

r.a,

m, g,_ ^

'2 cc: MRC 0360, 0658. 1 D. L. Borienbr,cger Attached are the following revisions to the OSR - Operational Safety Requirement Manual assigned to you:

o TR/IRTS-7 Rev. 2 Table of Contents Please ensure that all personnel under your cognizance are familiar with this manual.

Any copies of Operational Safety Requirements or Technical Requirements are to be marked UNCONTROLLED before distributed, i

' s' To acknowledge receipt of'the above items, please sign and return the attached distribution sheet by March 27, 1989 to:

s West Valley Nuclear Services Co..

Inc.

P. O. Box 191 West Valley, New York 14171-0191 Attn: Ms. Diana L. Smithmeyer Oa d Vn. &

Carol M. Schiffhauer, Supervisor Document Control West Valley Nuclear Services Co.,

Inc.

CMS: dis

Attachment:

TR/IRTS-7, Rev. 2 Table of Contents 0

\\

,1

\\.")

SAR0001:ENG-anR f

1 f

8904030155 890316 PDR PROJ 25359 L

M-32 PDC 1

I

i 9

t i

Document Control ilF:89:0129 March 16, 1989 WVDP OSR, Volume VI i

Controlled Distribution ec: MRC 0360, 0658, 1350, 1360 D. L. Bonenberger Attached are tae following revisions to the OSR - Operational Safety Requ>rement Manual assigned to you:

o TR/IRTS-7 Rev. 2 Table of Contents Please ensure that all personnel under your cognizance are familiar with this manual.

Any copies of Operational Safety Requirements or Technical Requirements are to be marked UNCONTROLLED before distributed.

To acknowledge receipt of the above items, please' sign and return the attached distribution sheet by March 27, 1989 to:

West Valley Nuclear Services Co.,

Inc.

P. O.

Box 191 West Valley, New York 14171-0191 Attn: Ms. Diana L. Smithmeyer Oaul 511

' kaun Carol M.

Schiffhauer, Supervisor Document Control West Valley Nuclear Services Co.,

Inc.

CMS: dis

Attachment:

TR/IRTS-7, Rev. 2 Table of Contents p

l

~'

SAR0001:ENG-SAR

D CONTROLLED DISTRIBUTION

~

WVDP OSR, VOLUME VI COPY NUMBER RECIPIENT 3.

Jensen, W. D.

(DOE-ID) 4 McIntosh, T. W.

(DOE-HQ) 5.

McIntosh, T. W.

(DOE-HQ) 6.

Huet, R. D.

(NRC-HQ) 7.

Hurt, R. D.

(NRC-HQ)

$^ 8 ',' '

1 Hurt," R.?"D'i

,.(NRCiHQ)m. l}

91

' Hurt','R' D.

(NRC-HQ) 10 Hurt, R. D.

(NRC-HQ) 12 Gecsr.er, R. F.

15 Knabenschuh, J. L.

16 Keel, R. B.

17.

Pope, J.

M.

18.

Schulz, R. W.

19.

Gwynar, J. C.

21.

Roberts, C. J.

~

22.

Humphrey, R. A.

23.

Curry, L. Y.

(WVNS Technical Library) 25.

DeBoer, T. K.

(NYSERDA-HQ) 26.

Spaunburgh, R. G.

(NYSERDA-WV) 27.

Lawrence, R. E.

28.

Garland, D. H.

29.

Plant Security Manager 30.

Shaffner, H. J.

(STS Control Room) 31.

Church, P. S.

(Shift Supervisor's Office)

)

32.

Pezzimenti, D. F.

(LWTS/ CSS Control Room)

'/

33.

Feldman, D. G.

(Drum Cell Control Room) 34.

Yeazel, J. A.

(DOE-WV) 35.

Englert. A.

E.

37.

Dooley, D. A.

38.

Harward, D. J.

39.

Sawyer, D. J.

40.

Ploetz, D. K.

41.

Steffes. D. R.

42.

Shugars, D. L.

43.

.Borisch, R. R.

44.

Murawski, T. F.

46.

Freaney, W.

P.

47.

Englert, J. P.

48.

Picazo, E. D.

49.

Schif fhauer, C. M.

(Document Control) 50.

Mayer, E. J.

(Buffalo and Erie County Library)

Signed:

Dated TR/IRTS-7. Rev. 2 HF:89:0129 03/16/89 l

l

/~%

i ;

i

' ()

SAR0001:ENG-SAR l

l.

L

4

.-.j;

- ~,.

w OPEtMTIONAL SAFETY REQUIREMENTS / TECHNICAL REQUIRFRENTS l-

'+

i

. WEST VALLEY DEMONSTRATION PROJECT WDP Former WDP, - NFS Identifier Rev.

Title / Contents Identifiers

'OSR-GP-11 1

WDP Airborne Radioactivity M.11.5.2.4.

Release Limits WDP 4.1.

OSR GP-1 OSR/TR-GP 0SR-CP-2 l'-

Radioactivity Content of Liquid.'

M.11.5.2.5.

Effluents Released from the WDP.

WDP 4. 2 -

OSR-GP-2 1.'

OSR/TR-GP-2 OSR-GP-3 2

Building and Vessel Ventilation M.11.5.2.1.

Systems Operability NFS 5.3, STS 1.1, 1.2, CSS 4.1, 4.2, SRF 8.2, LWTS 5.1 M.11.5.2.7.

WDP 4.14 LWTS 5.2,

.,A.

NFS 6.5,

(,).

STS.I.2, 1

CSS 4.2 M.11.5.2.8.

TVS 3.0 M.11.5.2.1 VF 2.2, 2.3 OSR GP-3 OSR/TR-CP-3

'OSR-GP-4 1

Effluent and Environmental.

M.11.5.2.1.B.X Monitoring (WDP 5.1)

OSR GP-4 OSR/TR-GP-4 i

l e

.p.

BLB0578:ENG 392 DATED 03/16/89

(._.

I

)

WVDP' former WVDP, NFS Identifier

'Rev.

? Title / Contents

__ Identifiers n

t-(

OSR-CP-5 1

WVDP Emergency Power Requirements M.11.5.4.3.

NFS 6.4 M.ll.5.2.1.D STS 1.3-M.11.5.2.1.G CSS 4.4 OSR GP-5 OSR/TR-GP-5 TR-GP-6 1

Storage Requirements for M.11.5.2.1.J Low-Level Waste LAG-1, LAG-2 M.ll.5.2.1.I SRF 8.4 TR-GP-6 OSR/TR-GP-6 OSR-CP-7 1

Criticality Safety for Liquid M.11.5.2.2.

Transfer WVDP 4.3 OSR GP-7 j

OSR/TR-GP-7

~/h T'R-GP-8 1

Water Activity Alarms M.11.5.4.1, L_ /

NFS 6.9 TR GP-8 OSR/TR-GP-8 TR-GP-9 1

Control of Plant Equipment New Function and Configuration TR GP-9 OSR/TR-GP-9 OSR-GP-10 1

Airborne Effluent Monitoring M.11.5.4.4.

System Operability NFS 6.5 STS 1.1, 1.2 CSS 4.1 OSR GP-10 OSR/TR-CP-10 OSR-CP-11 2

Storage Canister Loading and M.11.5.1.2.B Spacing AFM 6.0 STS 1.4, CSS 4.3, LWTS 5.3 OSR GP-11 l

OSR/TR-3P-11

,y BLB0578:ENG-392 DATED 03/16/89 l (

)

l \\e

~

l 1

l

y.%;..,,. -

c.

y:

,~.:

44

'3/

I*k

[::

Forme r ' WDP, NFS.

7,

.3WDP C

4

[

(

' Identifier-Rev.

Title / Contents Identifiers M gj", -

. 0SR-GP-12---

1 ---

Fissile Material Limits and-

.M.11.5.1;1.B b

Reg'uirements for Waste' Packages CPCRIT 9.1, g-

'9.3,. SIS-1.4,.

("

'TRU-9.1, 9.'2,.

LAG-l',: LAG-2i M.11.5.1'.1.J RER 1.1'

~M.11.5.4;1.J1 RER 1.3.

-M.11.5.6.1.J.

RER-1.2.

OSR GP-12.:

OSR/TR-GP-12 7

TR GP-13.

l' Evacuation Alarm and Emergency New Paging System Operability TR GP 13 OSR/TR-GP-13 TR-CP-14

-. l.

WDP Meteorological System New Operability

TR GP-14

.OSR/TR-GP f-

'TR-GP-15 1

Fire Brigade and Emergency-

.New Response Team Training.

TR GP-15 OSR/TR-GP-15 New TR GP-16 1

Plant Fire Protection Systems

. TR GP-16 OSR/TR-GP-16 OSR IRTS.1'

-2 Maintenance of Carbon Steel M.11.5.2.6.

liigh-Level Waste Tank Integrity NFS 4.12 M.11.5.4.2.

NFS 6.3.

0SR IRTS-1 OSR/TR-IRTS-1

.TR-IRTS-2 2

Control of CSS Recipe for M.11.5.2.2.0 Decontaminated Supernatant CSS 4.3 TR IRTS 2 OSR/TR-IRTS-2 m

-A BLB0578:ENG-392 DATED 03/16/89 U

Title / Contents Identifiers

)

OSR IRTS-3 1

Maintenance of Spare HLW M.11.5.2.3.

x-Storage Capacity NFS 5.4 OSR IRTS-3 OSR/TR-IRTS-3 TR-IRTS-4 2

Depressurization of STS for M.11.5.6.1.D Maintenance TR IRTS-4 OSR/TR-IRTS-4 TR-IRTS-S 3

STS Process Instrument Limits M.11.5.1.1.D STS 1.4 TR IRTS-5 OSR/TR-IRTS-5 TR-IRTS-6 1

LWTS Manifold Control New TR IRTS-6 OSR/TR-IRTS-6 TR-IRTS-7 2

Sampling and Anal'

's New f

Requirement for Tank 5-D-15B M.11.5.1.1.H LWTS 5.3 TR IRTS-7 7N, OSR/TR-IRTS-7

/

'~

TR-IRTS-8 3

Sampling and Analysis New Requirements for Tanks 5-D-15 Al and A2.

TR IRTS-8 OSR/TR-IRTS-8 a

Bl.B0578:ENG-392 DATED 03/16/89

,- s i

)

x_/

3 s v-OPERATIONAL SAFETY REQUIREMElfrS/ TECHNICAL REQUIREMENTS WEST VALLEY DEMONSTRATION. PROJECT y g.

s.- ' *)..

WDP For'.aer WDP, NFS Identifier:

Rev.

Title / Contents Identifiers j' t.

[

-OSR GP-1 lI WDP' Airborne Radioactivity :

M.11.5.2.4 L

Release' Limits WDP 4.1

-0SR GP-1 OSR'TR-CP-1

/

OSR-GP-2 1

Radioactivity Content of Liquid M.11.5.2.5.

Effluents Released from the WDP '

WDP 4.2 OSR-GP-2 OSR/TR-GP-2 OSR-CP-3 2

Building and vessel Ventilation-M.11.5.2.1.

Systems Operability

'NFS 5.3, STS 1.1, 1.2, CSS 4.1, 4.2, SRF 8.2, LWTS 5.1 M.11.5.2.7.

WDP 4.14 LWTS-5.2,

/]

NFS 6.5, (f.

STS-1.2, CSS 4.2 M.11.5.2.8.

TVS 3.0 M.11.5.2.1 VF 2.2, 2.3 OSR GP-3 OSR/TR-CP-3 OSR CP-4 1

Effluent and Environmental M.11.5.2.1.B.X.

Monitoring (WDP 5.1)

OSR GP-4 OSR/TR-GP-4 7 -

BLB0578:ENG 392 DATED 03/16/89

((

--.. 7 WVDP Former WVDP, NFS.

Identifier Rev.

Ti tle/ Contents Identi fie rs

.0SR-GP-5 1

WVDP Emergency Power Requirements M.11.5.4.3.

NFS 6.4 M.11.5.2.1.D STS 1.3 M.11.5.2.1.G CSS 4.4 OSR GP-5 OSR/TR-GP-5 TR-GP 6 1

Storage Requirements for M.11.5.2.1.J Low-Level Waste LAG-1, LAG-2' M.11.5.2.1.I SRF 8.4 TR-GP-6 OSR/TR-GP-6 OSR-GP-7 1

Criticality Safety for Liquid M.11.5.2.2.

Transfer WVDP 4.3 05R GP-7 OSR/TR-GP-7 TR-GP-8 1

Water Activity Alarms M.11.5.4.1.

/

NFS 6.9 N

TR GP-8 OSR/TR-CP-8 TR GP-9 1

Control of Plant Equipment New Function and Configuration TR GP-9 OSR/TR

'- 9 OSR-CP-10 1

Airborne Effluent Monitoring M.11.5.4.4 System Operability NFS 6.5 STS 1.1, 1.2 CSS 4.1 OSR GP-10 OSR/TR-CP-10 OSR-GP-11 2

Storage Canister Loading and M.11.5.1.2.B Spacing AFM 6.0 STS 1.4, CSS 4.3, LWTS 5.3 OSR GP-11 OSR/TR-GP-ll l

I BLB0578:ENG-392 DATED 03/16/89 r~ms.

_.)

L

f,?

k

) ng r

1 WDP.

Former WDP,:. NFS ;

'Ydentifier '

Rev.

Title / Contents' Identifiers

.l }g sy 50SR-GP-12' l'-

. Fissile Material Limits and

' M.11; 5.1.1~. B

-~

Requirements for Waste Packages' CPCRIT 9.1,-

9. 3, : STS - l'. 4,

^

TRU 9'1, 9.2,.

. LAG-1,. LAG-2:'

'M.11.5!1.1.J i RER 1.1 '

..M.11.5.4.1.J.

RER :1'. 3 :

M.11. 5.' 6.' 1. J

..t-RER 1.2 OSR GP-12 OSR/TIl-GP-12 TR-GP-13

'1

' Evacuation Alarm and Emergency New Paging System Operability.

TR GP-11 OSR/TR-CP-13

.TR-GP 14 1

WDP Meteorological System New,

Operability TR'GP-14 3

.0SR/TR-GP :.Q V !'

.TR-GP-15 1.

Fire Brigade and Emergency New

~

Response Team Training.

TR GP-15 OSR/TR-GP-15 TR-GP-16' 1

Plant Fire Protection Systems New TR GP-16 OSR/TR-GP-16 OSR-IRTS 1 2

Maintenance of carbon' Steel-M.11.5.2.6.

High-Level Waste Tank Integrity NFS 4.12 M.11.5.4.2.

NFS 6.'3 OSR IRTS-1 OSR/TR-IRTS-1

.TR-IRTS-2 2

Control of CSS Recipe for M.11.5.2.2.G Decontaminated Supernatant CSS 4.3 TR IRTS-2 OSR/TR-IRTS-2

's BLB0578:ENG-392 DATED 03/16/89

)

F b

1

~

Y WVDP Former WVDP, NFS Identifier Rev.

Title / Contents Identifiers

~.

s

)

l OSR-IRTS-3 1

Maintenance of Spare HLW M.11.5.2.3.

l Storage Capacity NFS 5.4 OSR IRTS-3 OSR/TR-IRTS-3 TR-IRTS-4 2

Depressurization of STS for M.11.5.6.1.D Maintenance TR IRTS-4 OSR/TR-IRTS-4 TR-IRTS-5 3

STS Process Instrument Limits M.11.5.1.1.D STS 1.4 TR IRTS-5 OSR/TR-IRTS-5 TR-IRTS-6 1

LWTS Manifold Control New TR IRTS-6 OSR/TR-IRTS-6 TR-IRTS-7 2

Sampling and Analysis New Requirement for Tank 5-D-15B M.11.5.1.1.H LWTS 5.3

TR IRTS 7

'^'

OSR/TR-IRTS-7 Ns TR-IRTS-8 3

Sampling and Analysis New Requirements for Tanks 5-D-15 Al and A2.

TR IRTS-8 OSR/TR-IRIS-8 i

~s-BLB0578:ENG-392 DATED 03/16/89

(

)

(,/

_ _ _ _ _ - - _ _ - _ _ _ _ _ _ _