Forwards Revised Tech Spec 3.3.3.2,correcting Typos Made in 870120 Amend Request Governing Incore Detector Sys.Safety Evaluation Contained in NRC 880503 Safety Evaluation Correctly Addresses Recalibr of Excore Detector Sys
ML20247D876
Person / Time
Site: Calvert Cliffs  
Issue date: 09/04/1989
From: Cruse C
BALTIMORE GAS & ELECTRIC CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20247D879 List:
References
NUDOCS 8909150108
Download: ML20247D876 (2)


Text

7_

2

~

V.

BALTIMORE p

.~

GAS AND ELECTRIC

' CHARLES CENTER. P.O. BOX 1475 BALTIMORE, MARYLAND 21203

' CHARLES H. CRUSE ~

MANAGER R'-

, NUCLEAR ENGINEERING SERVICES tlEPARTMENT September 4,1989 U.~ S. Nuclear Regulatory Commission Washington, DC 20555 ATTENTION:

Document Control Desk

SUBJECT:

Calvert Cliffs Nuclear Power' Plant Unit Nos.1 & 2; Docket Nos. 50-317 & 50-318

't 1 Technical Specification 3.3.

3.2 REFERENCES

(a) Letter-from Mr. J. A. Tiernan (BG&E) to NRC Document Control' Desk, dated January 20, 1987, Request for Amendment

. (b) Letter. from Mr.

S.

A.

McNeil (NRC) to Mr.

J.

A.

Tiernan

.(BG&E), dated May 3,1988, Technical Specification Amendments for Calvert Cliffs Nuclear Power Plant Units -I and 2 Gentlemen:

In Reference (a), we requested a change to the Unit 1 Technical Specification which

. governs the Incore Detector System. Because of the poor quality of 'the existing Tenhnical Specification page (attached), we provided you a retyped page prior to the issuance of Reference (b). Recently, we discovered several typing errors in this Technical Specification which changed its intent. We request that a corrected page (attached) be issued to correct this problem.

The first error is found in 3.3.3.2.b which now addresses the re-calibration of incore

' detectors..It is clear from a comparison with the previous Technical Specification that the correct wording should be excore detecton. Additionally, it is ' physically

. impossible to calibrate the incore detectors using the equipment listed in 3.3.3.2.b.

The Safety Evaluation. contained in Reference (b) correctly addresses the re-calibration

- of the excore detector. system. We have continued to re-calibrate the excore detector system using at least the minimum equipment required to be operable by 3.3.3.2.b.

[

8909150108 890904 i i PDR ADOCK 05000317 p

FDC

I 4

~!

DocumGnt Control Desk

-September 4,1989

.'Page 2.

I i

The next ' error 'is found in Technical Specification 3.3.3.2.c.l.

The specification currently. addresses. 75% of ' all incore detector agments, it should - address' incore detector ~ locations. Both References (a) and (b)' correctly address incore ' detector

. locations in the text. If the. wording is not corrected, it could result in a condition

'less conservative-than was intended. Given the definitions of an operable detector segment and an operable detector location, it would be possible to render 50% of the -

detector locations' inoperable while maintaining. 75% of the_- detector segments operable.

Therefore, the. wording of the ; Technical Specification should be corrected so it will of ' the specification established in the Safety Evaluation.

meet the intent Should you have any 'further questions regarding this matter, we will be pleased ;to"

' discuss them ' with you.-