ML20247D665

From kanterella
Jump to navigation Jump to search
Grants 890321 Request for Withholding from Public Disclosure WCAP-12218, Evaluation of Thermal Stratification for Alvin W Vogtle Unit 2 Pressurizer Surge Line
ML20247D665
Person / Time
Site: Vogtle 
Issue date: 05/16/1989
From: Hopkins J
Office of Nuclear Reactor Regulation
To: Wiesemann R
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
References
NUDOCS 8905250539
Download: ML20247D665 (4)


Text

'

o ar d

UNITED STATES g

.[

g NUCLEAR REGULATORY COMMISSION

, r.'

l WASHINGTON, D 20555 l, 16, 1989 Docket No. 50-425 Mr. R. A. Wiesemann Mana5er,. Regulatory & Legislative Affairs Westinghouse Electric Corporation P.O. Box 355 Pittsburgh, Pennsylvania 15230-0355

Dear Mr. Wiesemann:

SUBJECT:

REQUEST FOR WITHHOLDING FROM PUBLIC DISCLOSURE (CAW-89-046)

By letter dated March 22, 1989, Georgia Fower Company submitted WCAP-12218,

" Evaluation of Thermal Stratification for the Alvin W. Vcgtle Unit 2 Pressurizer Surge Line" and requested that it be withheM from public disclosure pursuant to 10 CFR 2.790. Georgia Power Company also submitted

.-your affidavit dated March 21, 1989.

You stated that the submitted information should be ccasidered exempt from mandatory public disclosure for the following reasons:

1.

The information is owned and has been held in confidence by Westinghouse.

2.

The information is of a type customarily held in confidence by Westinghouse and not disclosed to the public.

4 3.

The information was transmitted to the Connission in co'fidence.

4.

The information is not available in public sources.

I 5.

Public disclosure of the information would likely cause substantial harm to the competitive position of Westinghouse.

We have reviewed your application and the material in accordance with the requirements of 10 CFR 2.790 and, on the basis of your statements, have determined that the submitted information sought to be withheld contains trade secrets or proprietary connercial information.

disclosure pursuant to 10 CFR 2.790(prietary, will be withheld from publicb)(5) an Therefore, WCAP-12218, narked as pro Energy Act of 1954, as amended.

Withholding from public inspection shall not affect the right, if any, of persons properly and directly concerned to inspect the documents.

If the need arises, we may send copies of this information to our consultants working in this area. We will, of course, ensure that the consultants have signed the appropriate agreements for handling proprietary information.

i I

pfel yRO5250539 890516 m l

p ADOCK 05000425,

)

PNUT 4

Mr. R. A. Wiesemann May 16, 1989 If the basis for withholding tris information from public inspectif.n should l

change in the future such that the information could then be made available for public inspection, you should promptly notify the NRC. You also should understand tht t the NRC may have cause to review this determination in the future, for e> smple, if the scope of a Freedom of Information Act request includes your information.

In all review situations, if the NRC makes a determination adverse to the above, you will be notified in advance of any public disclosure.

Sincerely, l

on B. Hopkins, Project Manager Project Directorate 11-3 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation l

Mr. R. A. Wiesemann May 16, 1989 If the basis for withholding this information from public inspection should change in the future such that the information could then be made avai'*ble for public inspection, you should promptly notify the NRC. You also should understand that the NRC may have cause to review this determination in the future, for example, if the scope of a Freedom of Information Act request includes your information.

In all review situations, if the NRC makes a determination adverse to the above, you will be notified in advance of any public disclosure.

Sincerely,

5 Jon B. Hopkins, Project Manager Project Directorate 11-3 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation

[IllESEMANN LTR S/3]

DISTRIBUTION:

Dockect File '

NRC~POR' Local PDR PDll-3 Reading S. Varga 14-E-4 G. Lainas 14-H-3 D. Matthews 14-H-25 M. Roed 14-H-25 J. Hopkins 14-H-25 B. Kildee, OGC 15-B-18 Vogite Plant File OGC d[.PDII-3 PDII-3

('Olh3 f /dHopkins:ls BKildee MR'd66 05/f/89 05/ [ /89 05/p/89[WMatthews 05//6/89

.a Mr. W. G. Hairston, III Georgia Power Company Vogtle Electric Generating Plant cc:

Mr. J. A. Bailey Resident Inspector Manager - Licensing Nuclear Regulatory Commission Georgia Power Company P.O. Box 572 P.O. Box 1295 Waynesboro, Georgia 30830 Birmingham, Alabama 35201 James E. Joiner, Esq.

Bruce W. Churchill, Esq.

Troutmen, Sanders, Lockerman, Shaw, Pittman, Potts and Trowbridge

& Ashmore 2300 N Street, N.W.

1400 Candler Building Washington, D.C. 20037 127 Peachtree Street, N.E.

Mr. G. Bockhold, Jr.

General Manager, Nuclear Operations Mr. R. P. Mcdonald Georgia Power Company Executive Vice President -

P.O. Box 1600 Nuclear Operations-Waynesboro, Georgia 30830 Georgia Power Company P.O. Box 1295 Regional Administrator, Region 11 Birmingham, Alabana 35201 U.S. Nuclear Regulatory Commission 101 Marietta Street, N.W., Suite 2900 Mr. J. Leonard Ledbetter, Director Atlant, Georgia 30323 Environmental Protection Division Department of Natural Resources Office of the County Commissioner 205 Butler Street, S.E., Suite 1252 Burke County. Commission Waynesboro, Georgia 30830 Attorney General r

Law Department Office of Planning and Budget 132 Judicial Building Room 615B Atlanta, Georgia -30334 270 Washington Street, S.W.

Atlanta, Georgia 30334 Mr. Alan R. Herdt, Chief

~

Project Branch #3 '

Mr. C. K. McCoy U.S. Nuclear Regulatory Commission Vice President - Nuclear 101 Marietta Street, NW, Suite 2900 Georgia Power Company Atlanta, Georgia 30323 P.O. Box 1295 Birmingham, Alabama 35201 i

I l

l i

_