ML20247D124

From kanterella
Jump to navigation Jump to search
Supplemental Deficiency Rept CP-88-15 Re Containment Max Flood Level.Initially Reported on 880118.Corrective Actions Specified in Completed for Unit 1 W/Exception of Equipment Qualification Program Changes
ML20247D124
Person / Time
Site: Comanche Peak  
Issue date: 05/18/1989
From: William Cahill
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
CP-88-15, TXX-89266, NUDOCS 8905250174
Download: ML20247D124 (2)


Text

_.

E.

um EE Log # TXX-89266 Fi1e # 10110

.r

=

903.6 Ref.#10CFR50.55(e) 7UELECTRIC Wmiam J. Cahm, Jr.

Executhe Vice President U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C.

20555

SUBJECT:

COMANCHE PEAK STEAM ELECTRIC STATION (CPSES)

DOCKET N05. 50-445 AND 50-446 CONTAINMENT MAXIMUM FLOOD LEVEL 1

SDAR: CP-88-15 (SUPPLEMENTAL REPORT)

Gentlemen:

On January 18, 1988, by letter logged TXX-88115, TV Electric notified the NRC of a deficiency involving the containment maximum flood level.

The latest report was logged TXX-89065, dated February 14, 1989.

The purpose of this report is to update the corrective action, and to correct the discussion of Design Basis Documents (DBDs) related to this issue.

The corrective actions previously specified for this issue in TXX-88115, dated January 18, 1988, indicated that the incore instrumentation room door would be modified, the containment design flood level recalculated and the Equipment Qualification (EQ) program appropriately revised. These actions have been completed for Unit I with the exception of the EQ program changes.

Since the recalculated maximum containment design flood level is less than the level used in the EQ program, the containment design flood level originally assumed in the EQ program is conservative. Accordingly, no changes to the EQ program are required to address this item.

TXX-88115 also indicated that DBD-ME-008, " Containment Analysis" and DBD-ME-076, " Postulated Environment for Equipment Qualification" provided criteria related to maximum containment flood level.

However, maximum containnient flood level criteria is addressed only in DBD-ME-076, since the scope of DBD-ME-008 is limited to analysis of pressure and temperature inside the containment structure.

8905250174 spogig

{DR ADOCK 05000445 PDC 0

0 400 North Olive Street LB 81 Dallas, Texas 7$201 L

i d

l TXX-89266 May 18, 1989 Page 2 of 2 No further Unit 1 corrective action is required for this issue.

The Unit 2 corrective action implementation schedule remains unchanged.

{

Sincerely, l

William J. C hill, Jr.

HAM /ddm c - Mr. R. D. Martin, Region IV Resident Inspectors, CPSES (3) 1