JOSEPH M. FARLEY NUCLEAR PLANT UNIT 2 NARRATIVE SUbMARY OF OPERATIONS April, 1989 The Cycle 6 - 7 refueling outage continued through the month of April.

The following major safety-related maintenance was performed in the month of April:

l 1.

The reactor was de-fueled and visual inspections of the reactor vessel were completed. The fuel, including 65 fresh assemblies, was placed back into the reactor vessel.

2.

Eddy current examinations were performed on tubes in all three steam generators. As a result of this inspection program, 27 tubes were plugged:

11 on the 2A steam generator, 12 on the 2B steam generator, and four on the 2C steam generator.

In addition, 137 tubes were designated F5:

18 on the 2A steam generator, 30 on the 2B steam generator, and 89 on the 20 steam generator.

The plug in plug device was also installed in steam generator mechanical tube plugs as detennined by an evaluation of the corrosion propensity of plugs. The evaluation of the corrosion propensity of tube plugs is based on considerations such as material conditions and operating temperatures. As a result of this evaluation, 172 plug in plug devices were installed:

25 on the 2A steam generator, 50 on the 2B steam generator, and 97 on the 2C steam generator.

3.

The program for performing physical and calibration inspections of the HFA relays continued.

4.

The program for refurbishing the actuators on motor-operated valves continued.

5.

Miscellaneous corrective and nreventive maintenance was Ierfonsed on the diesel generators.

i

)

1 I

1 l

1 g5240377890430 R

ADOCK 05000364

\\\\

PNu l

u ____.__ __________ _

OPERATING DATA REPORT DOCKET No. 50-364 DATE 5/2/89 COMPLETED BY D. N. Morey TELEPHONE (205)899-5156 OPERATING S'ENIUS Notes

1. Unit Name:

Joseph M. Farley - Unit 2

2. Reporting Period:

April, 1989

1) Cumulative data since
3. Licensed Thermal Power (MWt):

2,652 7-30-81, date of

4. Nameplate Rating (Gross MWe):

860 commercial operation

5. Design Electrical Rating (Net MWe):

829

6. Maximum Dependable Capacity (Gross MWe):

870.3 l

.7. Maximum Dependable Capacity (Net MWe):

829.7

8. If Changes Occur in Capacity Ratings (Items Number 3 Through 7) Since Last Report, Give Reasons: N/A
9. Power Level To Which Restricted, If Any (Net MWe):

N/A

10. Reasons For Restrictions, If Any:

N/A

'Ihis Month Yr-to-Date Cumulative

11. Hours In Reporting Period 719 2,879 67,968
12. Number Of Hours Reactor Was Critical 0.0 1,995.3 58,673.2
13. Reactor Reserve Shutdown Hours 0.0 0.0 138.0
14. Hours Generator On-Line 0.0 1,991.6 58,024.2
15. Unit Reserve Shutdown Hours 0.0 0.0 0.0
16. Gross Thermal Energy Generated (MWH) 0 5,170,729 147,368,365
17. Gross Electrical Energy Generated (MWH) 22 1,707,514 48,443,000
18. Net Electrical Energy Generated (MWH)

-3520 1,620,474 45,945,760

19. Unit Service Factor 0.0 69.2 85.4
20. Unit Availability Factor 0.0 69.2 85.4
21. Unit Capacity Factor (Using MDC Net)

-0.6 67.8 82.8

22. Unit Capacity Factor (Using DER Net)

-0.6 67.9 81.5

23. Unit Forced Outage Rate 0.0 0.0 4.4
24. Shutdowns Scheduled Over Next 6 Months (Type, Date, and Duration of Each):

N/A i

23. If Shut Down At End Of Report Period, Estimated Date of Startup: 5/11/89
26. Units In Test Status (Prior to Commercial Operation):

Forecast Achieved INITIAL CRITICALITY 05/06/81 05/08/81 INITIAL ELECTRICITY 05/24/81 05/25/81 COMMERCIAL OPERATICN 08/01/81

___ 07/30/81 Form 2/30

8 m..

f DOCKET No.

50-364 q

UNIT 2

DATE MAY 1, 1989 COMPLETED BY D. N. Morey TELEPHONE'(205)899-5156 MONTH APRIL j

L DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MNe-Net)

(MWe-Net)

'l 0

17 0

2 0

18 0

3 0

19 0

4 0

20 0

5 0

21 0

6 0

22 0

7 0

23 0

8 0

24 0

9 0

25 0

10 0

26 0

11-0 27 0

12 0

28 0

l 13 0

29 0

14 0

30 0

15 0

31 16 0

INSTRUCTIONS on this. format, list the average daily unit power level in MWe-Net for each day in the reporting month. Compute to the nearest whole megawatt.

1

. Form 13/21

j I!ll1 1

i e

.zJ

?

~

lIIlIIIIII!IIIIII lll ll 2

TINU

. d 6

Y 5

e E

9 T1

. u L

8 E

3 n

R 9

R b i

A 1

O t

4 M

2

. n' F

o 6

4

)

c 3

M N

5 Y

0 e'

A 2

g 0

5 J

M D

(

a E

E t

G V

C ul E

I ~

N oi R

T' E

r U

O E E Y E C

R g p e N N M T B N E O R nA e

(

A A O

R T U i

a s T N D D H R

C l f s t n e e

E E P O N E e o n a el c

R T T E C O R u

o D ci r

C I E L I

f h i

i F u

O N L E

& T T e t t f L o

D U P T C N r n c o

)

S M

E A E o'

u r R O

S V

7 m r n o E e

C U

E t of L m

A R

6 e s i

(

a C

P h

nt s t S

et I a t r l

- r e o ch G a e p I

. y g ph e c u t e S R t

o i r i

e r b P yt

)

b h h i

r n1 i

T t h r t e6 h

x o n v1 x

lll IlliIIIIIIIIIIIIIII E f E E 0 E

T S

N N

E O

N I

O A

T P E

/

C M D N

U O O D

C C EE lll illIIIIIIIIIIIIIIII L

R I

M E

R E

W P

T E A

O A

S D

/

m)

P Y

O.

N a n S C

. r i D

H mc a N

T lll IllIIIIIIIIIIIIIIII a S l A

N r

p O

c c xE 3

M E

9 S i

(

N E

t W

T S

T l l a

a a m r O

R N T R D

O E N O A

d u u o e T

P C E P

/

o n nt h U

E I V E N

h a a ut N

R L E R t M M A O e - - - -

S lll illIII1IIIIII1IIIII M 1 2 3 4 T

INU ROT F

C O G A n

N E o

D I R i

O T 1

t H T N a

T U W n

E H O.

i M S D max lll IllIIIiIIIIIII1IIII E

)

e

)

NO n

s n

S i

n i

A C

a e

a E

l c

l R

p ni p

x o L x

lll illIIIIIIIIIIIiIIII E

i E

(

t t &

(

s c

N e e i g r

O

)

r T r n o

u t i r

)

I S 0

l r s n e r n T R A U 9

i o ei v E i R O 1

a R a i a

U H 7

F e r t l l c

yT a a p D

(

t n g r r n x lll IlllIIIIIIIIIIIIIII n a n o r t o (E

e nit o si m el a t i t p t el a n a r E

ni n u ur i r e P

o uif g e m eh Y

S s q a e e pd p t T

a E M R R O A O O e - - - - - - - -

lll IlliIIIIIiIIII1IIII R A B C D E F G H 1

0 E

4

.T 0

d 2v A

9 e

D 8

l lll IllIIIIIIlIIIIIIIII d u e d m

c e x

r h 0

F S 7) a 2

o c 0

7 n

/

O u

N F S 9

. lll IllIIIlIIIIIIIIIIII

(

ijIlilll (l

f_-

' Alabama Power Company 600 North 18th Street Post Office Box 2641 Birm' gham, Alabama 35291-0400 m

' Telephone 205 250-1974 J. D. Woodard Vice President AlabamaPower 8#"

'NA-89-2246 Docket No. 50-364 U. S. Nuclear Regulatory Conmission ATIN: Document Control Desk Washington, D. C.

20555 Joseph M. Farley Nuclear Plant Unit 2 Monthly Operating Data Report Attached'is the April 1989 Monthly operating Report for Joseph M. Farley Nuclear Plant Unit 2, required by Section 6.9.1.10 of the Technical Specifications.

If you have any questions, please advise.

Yours very t ly,

/ x/L J.

). Woodard JDW/JGS:sme/1.6 Attachments 1

cc:

Mr. S. D. Ebneter Mr. E. A. Reeves Mr. G. F. Maxwell 1