ML20247B783

From kanterella
Jump to navigation Jump to search

Submits Response to Generic Ltr 89-08, Erosion/Corrosion- Induced Pipe Wall Thinning. Program Implemented That Utilizes Systematic Measures to Ensure That Integrity of High Energy Carbon Steel Sys Maintained
ML20247B783
Person / Time
Site: Davis Besse 
Issue date: 07/14/1989
From: Shelton D
TOLEDO EDISON CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
1679, 2940, GL-89-08, GL-89-8, TAC-73476, NUDOCS 8907240206
Download: ML20247B783 (3)


Text

-

t

-e

[ @l TOLEDO EDISON

. A Centsw Dergy Cernpeny DONAU3 C. SHELTON M Pretw1ent-Nuuoar '

Docket Number 50-346 License Number NPF-3 Serial Number 1679 July 14, 1989 United States Nuclear Regulatory Commission Document Control Desk Washington, D. C.

20555

Subject:

Response to Generic Letter 89-08,

  • Erosion / Corrosion-Induced Pipe Vall Thinning" Gentlemen:

Pursuant to 10CFR50.54(f), the United States Nuclear Regulatory Commission (NRC) issued Generic Letter 89-08, " Erosion / Corrosion-Induced Pipe Vall Thinning" dated May 2, 1989 (Log Number 2940), requiring information to assess safe operation of reactors when erosion / corrosion significantly degrades piping and components of high energy carbon steel piping systems. The staff requested a response identifying whether or not a long term erosion / corrosion monitoring program has been developed that provides assurances that procedures or administrative controls are in place.

Toledo Edison implemented a formal long term' erosion /cerrosion control program on April 19, 1988 at the Davis-Besse Nuclear Power Station. This program is administered under Engineering procedure EN-DP-01301 Erosion-Corrosion Monitoring and Analysis Program (CENAP). The program provides analysis of high-energy carbon steel piping systems utilizing computer codes, non-destructive examination and evaluation of inspection results, data retention and trending of degraced components, and implementation of repair actions necessary to restore proper system integrity as a result of inspection findings. This program utilizes systematic measures to ensure that the integrity of high energy (two phase, as well as single phase) carbon steel systems is maintained. In addition, Toledo Edison's Erosion-Corrosion Monitoring and Analysis Program meets the intent of NUMARC guidelines (Appendix A of NUREG 1344).

Therefore, Toledo Edison believes the current CEMAP at Davis-Besse satisfies the concern raised in Generic Letter 89-08.

of46 00!

PDC Ifd THE TOLEDO EDISDN COMPANY EDISON PLAZA 300 MADISON AVENUE TOLEDO, OHIO 43652

~

,1

.7g..Decket Number 50-346 L-

,s.'

- Licenca Number NPF-3

L.

. Serial Number 1679; l..

Page 2 If you have~any questions concerning this matter, please contact.

Mr. R. _V. Schrauder, _ Nuclear Licensing Manager, at. (419) 249-2366.

Very trul

ours, CAB /dlm

- l I"

Attachment.

cc _ P. M. Byron, DB-1 NRC Senior Resident Inspector A. B. Davis, Regional Administrator, NRC hegion III T. V. Vambach, DB-1 NRC Senior. Project Managet

,/

__m__.__.

M 1

'9

; Dock';t Nu;ber-50-346 Licants Nusb:Ir NPF '

. Serial Number 1679i

. Enclosure Page 1.

Response tc Generic Letter 89-08 A

" Erosion / Corrosion-Induced Pipe Vall Thinning" For Davis-Besse Nuclear Power Station Unit Number 1 Toledo: Edison's response is. submitted pursuant to 10CFR50.54(f) for Generic Letter 89-08 " Erosion / Corrosion-Induced Pipe Vall Thinning."

By:

D. C. Shelton, Vice President, Nuclear Sworn and subscribed before me this 14th day of July,1989.

l l

tary Public, State of Ohio

' UDITH HIRSCH J

Notary Public State of Ohio My Commieslon Expires June 30, 1992 L_-__-___--_---__.--