ML20246Q020

From kanterella
Jump to navigation Jump to search
Monthly Operating Rept Summary for Jan 1998 for Univ of Missouri Research Reactor
ML20246Q020
Person / Time
Site: University of Missouri-Columbia
Issue date: 01/31/1998
From:
MISSOURI, UNIV. OF, COLUMBIA, MO
To:
References
NUDOCS 9805040400
Download: ML20246Q020 (3)


Text

_

l PRIORITY ROtM First

%d' 1

i RA RC ggt BC DRP SGA l

ORS G-- -

i PAO DNh4S C'*4'

[~at9tc%

i RLE,/ W -

UNIVERSITY OF MISSOURI RESEARCH REACTOR OPERATIONS MONTHLY

SUMMARY

JANUARY 1998 Prepared by:

-Operations Staff 9805040400 900131 PDR ADOCK 05000186 R

pm l-l MAR 0 313

y January 1998 The reactor opcrated continuously in January with the following exceptions: five shutdowns for scheduled maintenance and/or refueling; three unscheduled shutdowns.

On January 12, a rod not in contact with magnet rod run in occurred (twice) when control blade

'A' drive mechanism magnet separated from its " anvil" seating surface during routine blade shimming evolutions. After the first instance, the upper housing alignment was inspected and the magnet seating surface was cleaned. After the second instance, the lower blade housing aligrm.ent was adjusted and the reactor was returned to normal operation.

On January 31, a rod not in contact with magnet rod run in occurred when control blade 'A' drive mechanism was bumped during a routine sample handling evolution.

Major maintenance items for the month included: replacing the 'A' solenoid in the primary system nitrogen back; replacing the servo-potentiometer on the stack monitor iodine channel; adjusting the upper and lower guide tube housing on control blade 'A' drive mechanism; replacing control blade offset mechanism 'C'; replacing secondary pump P-3 inboard pump bearing.

UNSCHEDULED SIIUTDOWNS Date No.

Tyne Cause 1/12/98 1075 Rod Run-In Control blade 'A' separated from magnet during shimming 1/12/98 1076 Rod Run-In Control blade 'A' separated from magnet during shimming 1/31/98 1077 Rod Run-In Control blade 'A' bumped, causing separation from magnet OPEItATIONS

SUMMARY

llOURS OPERATED TIIIS PERIOD 664 TOTAL IIOURS OPERATED 209,375 IIOURS AT FULL POWER TIIIS PERIOD 660 TOTAL IIOURS AT FULL POWER 206,288 INTEGRATED POWER THIS PERIOD 275 MWD l

TOTAL INTEGRATED POWER 80,104 MWD 1

l

v i.

MAINTENANCE ACTIVITIES 01/03/S8. Refueled removed core 97-58, loaded core 981.

01/05/98 ' Refueled - removed core 98-1, loaded core 98-2. Replaced nitrogen bank 'A' solenoid.

' 01/12/98 Refueled - removed core 98-2, loaded core 98-3. Realigned control blade 'A' offset j

mechanism guide tubes.

. 01/19/98-Refueled - removed core 98-3, loaded core 98-4.

l

'01/23/98 Replaced 'the servo-potentiometer on the stack monitor iodine channel.

L

.. 01/26/98 Refueled removed core 98-4, loaded core 98 5. Replaced offset mechanism 'C'; replaced secondary pump P-3 inboard pump bearing.

01/31/98 Refueled - removed core 98 5, loaded core 98 6.

l l

t i

I p

i.-

OL:.

l - : _ _-..

: _ : : 2 : - _ _. _..