Text
.
.k A
.'q.
-w M UjllM gy;j"ev e we staten
- ?y.
Shippingport, PA 15077Kl04
^ f..) -
s
' JOHN D SIEBEM Vce Presrdent. Nuclear Group -
44121643 5255 August 22, 1989 U.
S.
Nuclear Pegulatory Commission
-Attn:
Document Control Desk Wasnington, DC 20555
Reference:
- Beaver Valley Power Station', Unit No. 1 Docket No. 50-334,; License.No. DPR-66 Radial Peaking Factor Limit Report - Cycle 8 Gentlemen:
Enclosed are the Cycle 8 Radial Peaking Factor Limit Report and' associated
- graph,
" Maximum (FQT X PREL). versus Core Height During Normal Operation".
This report has been prepared to satisfy the requirements of Technical Specification Administrative Control 6.9.1.14.
Very truly yours, Qi
?.,
D!Sle r
Vice President Nuclear Group cc:
Mr. J.
Beall, Sr. Resident Inspector Mr..W. T. Russell, NRC Region I Administrator Mr. P. Tam, Sr. Project Manager I
6 8909080048 890822 1'
I PDR ADOCK 05000334 P
FDC L
_____________________________-______-.___________________________________J
7, ; -c4
. BEAVER VALLEY UNIT A
[$
CYCLE 8 RADIAL PEAKING FACTOR LIMIT REPORT l
,f C'
This' Radial Peaking Factor Limit Report is provided in accordance with paragraph 6.9.1.14 of the Beaver Valley Unit 1 Technical Specifications.
The F-limits for RATED THERMAL POWER within specific core planes for D:
xy -
Cycle 8 shall be:
- 1. F 5 1.71 for all core planes containing D-BANK xy
- 2. For unrodded core planes F-s'1.70 from 1.8 ft. elevation to 2.05 ft, elevation xy F
s 1.74 above 2.05 ft. elevation to 3.25 ft. elevation F
s 1.72 above 3.25 ft. elevation to 3.65 ft. elevation F
5 1.7135 above 3.65 ft. elevation to 3.85 ft. elevation xy F
5 1.71 above 3.85 ft. elevation to 5.85 ft. elevation F
< 1.77 above 5.85 ft. elevation to 9.65 ft. elevation.
xy -
Fg51.71above'9.65ft, elevation to 10.2 ft. elevation xy(z) limits were used to confirm that the heat flux hot channel These F
. factor F (z) will be limited to-the Technical Specification values of:
9 F (z) 5 [2.40] [K(z)] for P > 0.5 and, q
p F (z) 5 [4.80] [K(z)) for P $ 0.5 q
assuming the most limiting axial power distribution expected to result from the insertion and removal of control banks C and D during operation, including the accompanying variations in the axial xenon and power distribution as described in the " Power Distribution Control and Load Following Procedures", WCAP-8403, September, 1974. Therefore, these F
limits provide assurance that the initial conditions assumed in the xy LOCA analyses are met, along with the ECCS acceptance criteria of
~10CFR50.46.
d'*
..[:
i MAXIMUM (FOT X PREL) VERSUS CORE HEIGHT lj DURING NORMAL OPERATION I
F T Limit F T Analyzed 4+++
q 2.6 0.00. 2.400
.III.I Ii 6.00, 2.400 l
Ii!llll lII I
cl;
'tlli i
'!!Ill ill illi i,
l'l ti 'll lill!!I
!!Il lll i
l l
ll l i
'li
't
!Ill lilil!!
llIll II'>j 2.4
.7
-,i N I I I I
il 10.8. 2.256-I i
- '. l i
'.L + i ! ! !
I ! i l+i+7 I I + 4.' '.T 11ll i: Il!'i i
'.i 11 llll1li
+ 1 l p.:.i i'
i i
ii ili il
.iill lillili i,l,illi++ g\\i i i
i i ll i.
2.2
. q., ;. ;
!,i!,;
- ,3;
- ). ;,
l\\
i i'!!
!i!!lil
'llil l
Illll!
II:llli i
L\\l 1
d I
tiill i l i l ll i
!!il I
lill!'
ii'llli I,\\
f Il'iII
'iiiI
'II!III IIII'I' IIf!III I
I II ' I 2'0 l'I'll!
! !!!!!i illlll' lilli!i Illllli l+\\.I
- !1 l l 1
'll!!! !
iilIll I
11!!1 ll1ll11 I I :\\ I
!1111!
i ltil:
illll 11 I!Il fli
!Il lilll
$,3 I!Illll lilll!
llll ll.1111 111lll!
lil\\1 3
R il!Ill l
lilli il!Ill I
'll!!
ililili i
i jJ \\1 5
i lill!
!!illi l
Illi llllll1 l i l l i, \\'
4 i,i g
BASIS FXY
.l!!!ll 1.6 llll!ll FROM 1.8 FT. TO 2.05 FT.
1.700 I i l l l 1 l\\
l;jjlll AB0VE 2.05 FT. TO 3.25 F1.
1.740 j
l l l*!
AB0VE 3.25 FT. TO 3.65 FT.
1.720 II II l
II I'
I AB0VE 3.65 FT. TO 3.85 FT.
1.7135 II II l
ABOVE 3.85 FT. 10 5.85 FT.
1.710 ll l
!I l4 ll l
l AB0VE 5.85 FT. TO 9.65 FT.
1.770 l
12.0, 1.536 AB0VE 9.65 FT. TO 10.2 FT.
1.710 g
- g ll l
1IIIIII III!III IilIi!I IIII l
!I
~0 2
4 6
8 10 12 CORE HEIGHT (FEET)
_ _ _ _ _ - _ _ - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ _