ML20246M182
| ML20246M182 | |
| Person / Time | |
|---|---|
| Site: | Vogtle |
| Issue date: | 02/28/1989 |
| From: | Moye R GEORGIA POWER CO. |
| To: | |
| Shared Package | |
| ML20246L996 | List: |
| References | |
| NUDOCS 8907190084 | |
| Download: ML20246M182 (3) | |
Text
[:
i r.
4 L-f OPERATING DATA REPORT-DOCKET NO. 50-424 DATE: MAR 5,'1989 COMPLETED BY: R.A. M0YE OPERATING STATUS 1.' UNIT NAME:
A. W. V0GTLE UNIT 1
- 2. REPORT PERIOD:
FEB 89 l-
- 3. LICENSED THERMAL POWER (MWt :
3411
- 4. NAMEPLATE RATING (GROSS MWe :
1148
- 5. DESIGN ELECTRICAL RATING N T MWe :
1101
- 6. MAXIMUM DEPENDABLE CAPACI Y GROS MWe):
1137
- 7. MAXIMUM DEPENDABLE CAPACITY NET MWe 1083
- 8. IF CHANGES DCCUR IN CAPACITY RATINGS):
'(ITEMS 3 THROUGH 7) SINCE LAST REPORT, GIVE REASONS:
- 9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWe):
NO RESTRICTIONS
-10. REASONS FOR RESTRICTION, IF ANY:
N/A THIS MONTH YR. TO DATE CUMULATIVE
- 11. HOURS IN REPORTING PERIOD:
672 1416 15337
- 12. NUMBER OF ' HOURS REACTOR WAS CRITICAL:
643.7 1200.1 12075.2
- 13. REACTOR RESERVE SHUTDOWN HOURS:
0.0 0.0 0.0
- 14. HOURS GENERATOR ON-LINE:
613.3 1153.8 11646.6
- 15. UNIT RESERVE SHUTDOWN HOURS:
0.0 0.0 0.0-
- 16. GROSS THERMAL ENERGY GENERATED H):
1905573 3677476 38108631.9
- 17. GROSS ELEC. ENERGY GENERATED 635870 1223790 12613860-
- 18. NET ELEC. ENERGY GENERATED (M 600480 1152480 11864610
- 19. REACTOR SERVICE FACTOR 95.8%
84.8%
78.7%
- 20. REACTOR AVAILABILITY FACTOR 95.8%
84.8%
78.7%'
- 21. UNIT SERVICE FACTOR:-
91.3%
81.5%
75.9%
- 22. UNIT AVAILABILITY FACTOR:
91.3%
81.5%
75.9%
- 23. UNIT CAPACITY FACTOR USING MDC NET :
82.5%
75.2%
71.7%
- 24. UNIT CAPACITY FACTOR USING DER NET :
81.2%
73.9%
70.3%
'25. UNIT FORCED OUTAGE RA E:
8.7%
17.5%
15.2%
- 26. SHUTDOWNS SCHEDULED OVER THE NEXT 6 MONTHS (TYPE, DATE, AND DURATION OF EACH):
- 27. IF SHUTDOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF STARTUP:
N/A
- 28. UNITS IN TEST STATUS ( PRIOR TO COMMERCIAL OPERATION):
N/A i
E2-2
[88" 8880 838?Qp J
UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO.
50-424 DATE:
MAR 5, 1989 UNIT NAME:
V0GTLE UNIT I COMPLETED BY: R. A. M0YE TELEPHONE:
(404) 724-8114 x3212 REPORT MONTH FEB 89 J
R M
5 E
E Y
T A
T LICENSEE SC Y
S H
EVENT T0 COMPONENT CAUSE & CORRECTIVE P
DURATION 0
0 REPORT-ED CODE ACTION TO NO.
DATE E
(HOURS)
N D
NUMBER ME (SUBCODE)
PREVENT RECURRENCE 89-2 02-10 t
b5.7z A T 89-005
- TJ-P 5tt stLOW 89-3 02 P
.198.4 A
5 89-006 SJ P
SEE BELOW F: FORCED
. REASON:
METHOD:
EVENTS REPORTED INVOLVE S: SCHEDULED A-EQUIPMENT FAILURE (EXPLAIN) I - MANUAL A GREATER THAN 20%
B-MAINTENANCE OR TEST 2 - MANUAL SCRAM REDUCTION IN AVERAGE C-REFUELING 3 - AUTO. SCRAM DAILY POWER LEVEL FOR D-REGULATORY RESTRICTION 4 - CONTINUATIONS THE PRECEEDING 24 HOURS.
E-0PERATOR TRAINING & LICENSE 5 - LOAD REDUCTION F-ADMINISTRATIVE 9 - 0THER (EXPLAIN)
G-0PERATIONAL ERROR (EXPLAIN)
H-0THER (EXPLAIN) 89-2 CAUSE: HIGH VIBRATION TRIP 0F MAIN FEEDWATER PUMP,"A", CAUSED A LOW LEVEL CONDITION IN STEAM GENERATOR #4.
CORRECTIVE ACTION: MAIN FEEDWATER PUMP HAS BEEN DISASSEMBLED AND INSPECTED TO DETERMINE CAUSE OF HIGH VIL.'.ATION. PUMP HAS BEEN REASSEMBLED AND TESTING HAS BEEN COMPLETED.
89-3 LAUSE: POWER REDUCTION DUE TO MAIN FEEDWATER PUMP "A" TAKEN OUT OF SERVICE FOR INSPECTION AND TESTING.
CORRECTIVE ACTION:
POWER INCREASE AFTER HAIN FEEDWATER PUMP "A" INSPECTED AND TESTED.
E24
UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO.
50-425 DATE:
MAR 5, 1989 UNIT NAME:
V0GTLE UNIT 2 COMPLETED BY: R. A. M0YE TELEPHONE:
(404) 724-8114 x3212 REPORT MONTH FEB 89 l
R M
5 E
E Y
T A
T LICENSEE SC Y
S H
EVENT T0 COMPONENT CAUSE & CORRECTIVE P
DURATION 0
0 REPORT ED CODE ACTION TO NO.
DATE E
(HOURS)
N D
NUMBER ME (SUBCODE)
PREVENT RECURRENCE NONE F: FORCED REASON:
METHOD:
EVENTS REPORTED INVOLVE 1 - MANUAL A GREATER THAN 20%
A-EQUIPMENT FAILURE (EXPLAIN) 2 - MANUAL SCRAM S: SCHEDULED B-MAINTENANCE OR TEST REDUCTION IN AVERAGE C-REFUELING 3 - AUTO. 3 CRAM DAILY POWER LEVEL FOR D-REGULATORY RESTRICTION 4 - CONTINUATIONS THE PRECEEDING 24 HOURS.
E-0PERATOR TRAINING & LICENSE 5 - LOAD REDUCTION F-ADMINISTRATIVE 9 - OTHER (EXPLAIN)
G-OPERATIONAL ERROR (EXPLAIN)
H-0THER (EXPLAIN)
E3-4 l