ML20246L750
| ML20246L750 | |
| Person / Time | |
|---|---|
| Site: | Millstone |
| Issue date: | 06/30/1989 |
| From: | Neron G, Scace S NORTHEAST NUCLEAR ENERGY CO., NORTHEAST UTILITIES |
| To: | NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM) |
| References | |
| MP-13288, NUDOCS 8907180506 | |
| Download: ML20246L750 (5) | |
Text
mw MbETHEAST UTILETIES
~
o.nor.i Ome... s.io.n sir..t. 8.rnn. Conn cticui 1
. w m a.c.e c,:aee w c
- P.O. BOX 270 5
] [om [.c [,, 1 7 ",. "
.l H ARTFORD. CONNECTICUT 06141-0270 k
(203) 665 5000 mw o.co.
1 July 10, 1989 I
)
Re:
10CFR50.71(a)
U.S. Nuclear Regulatory Commission Document Control Desk Vashington, D. C. 20555
Reference:
Facility Operating License No. DPR-65 Docket No. 50-336
Dear Sir:
.This letter is forwarded to provide the report of operating and shutdown experience relating to Millstone Unit 2 Monthly Operating Rep 6rt 89-06 in accordance with Appendix A Technical Specifications, Section 6.9.1.6.
One additional copy of the report is enclosed.
Very truly yours, NORTHEAST NUCLEAR ENFRGY COMPANY s
i N St en
. Scace Station Superintendent Millstone Nuclear Power Station a
SES/GN:dlr ec: V. T. Russell, Region I Administrator G. S. Vising, NRC Project Manager, 54illstone Unit No. 2 W. J. Raymond, Senior Resident Inspector, Millstone Unit Nos. 1, 2 & 3 l
1 l
i l
8907190506 890630 PDR ADOCK 05000336 f$Af l
L 2]l
f OPERATING DATA FCPORT DOCKET NO.
50-336 DATE 7/10/89 COMPLETED BY G. Neron TELEPHONE (203) 447-1791 Extension 4417 OPERATING STATUS 1.
Unit Name: Millstone Unit 2 Notes: Items 21 and 22 cumulative 2.
Reporting Period: June 1989 are weighted averages. Unit
,3.
Licensed Thermal Power (MWt): 2700 operated at 2560 MW thermal prior 4..
Nameplate ' Rating (Gross MWe): 909 to its uprating tv the current
.5.
Design Electrical Rating (Net MWe): 870 2700 MW thermal power level.
6.
Maximum Dependable Capacity (Gross MWe):893.88 7.
Maximum Dependable Capacity. (Net MWe): 8I2.88
- 8.
If Changes Occur in C;.pcity Ratings (Items Number 3 Through 7) 4 Since Last Report, Give Reasons: N/A
'9.
Power Level to Which Restricted, If Any (liet MWe): N/A 10.
Reasons For Restrictions, If Any: N/A This Month Year to Date Cumulative
- 11.. Hours In Reporting Pericci 720 _
4,343 118,463' 12.
Number Of Hears Reactor Was Critical 720.0 2,386.4 86,719.8
'13.
Reactor Reserve Shutdown Hours 0
0 2205.5
- 14. ' Hours General On-Line 720.0 2,271.6 82,337.0
~
- 15. Unit Reserve Shutdown Hours 0
0 468.2 16.
Gross 'Inermal Energy Generated (MWH) 1,938,383.0 5,984,553.0 228,635,833.0
- 17.. Gross Elec. Energy Generated (MWH) 641,256.0 1,962,931.5 68,793,452.0
- 18. Net Electrical Energy Generated (MXH) 619,048.0 1,877,394.5 65,986,541.0 19.
Unit Service Factor 100.0 52.3 69.5
- 20. Unit Availability Factor 100.0 52.3 69.9
- 21. ' Unit Capacity Factor (Using MDC Net) 99.6 50.1 65.6 22.
Unit Capacity Factor (Using DER Net) 98.8 49.7 64.6 23.
Unit Forced Outace Rate
~'
O.0 0.0 14.4 24.
Shutdowns Scheduled Over Next 6 Months (Type, Date, and Duration of Each):
Eddy Current Examination of Steam Generator Tubes: October 28, 1989: Approximate 1v 4-5 weeks 25.
If Shutdown at End of Report Period, Estimated Date of S*,artup:
i N/A
- 26. Units in Test Status (Prior to Commercial Operation):
Forcast Achieved INITIAL CRITICALITY N/A N/A INITIAL ELECTRICITY N/A N/A I
COMMERCIAL OPERATION
~
N/A N/A I
l 1
j 1
l 1
i e
_e-j
..VERAGE DAILY UNIT POWER LEVEL DOCKET NO.
50-336 1
UNIT Millstone 2 DATE 7/10/89 COMPLETED BY G. Neron' TELEPHONE- (203) 447-1791 Extension 4417-1 MONTH June 1919 DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net)
(MWe-Net) 1 863-17 862 2
861 18 863 3
794 19 862 4
84C 20 863 5
863 21 862 6
864 22-862 7
863 23 863 8
'863 24 863 9
863 25 863 10 864 26 862 11 864 27 862
- 12 863 28 862 13 863 29 862 14 863 30 862
- 15 862 31 16 863 INSTRUCTIONS l'
On-this format, list the average daily unit power level in MWe-Net for each day in the' reporting month. Computer tc the nearest whole megawatt.
l c
l
2 14 i
n i aei u
t e
tD cF o
e 7 n c - r c
i -
S
- n n4 o eor uf L)
- o9o4 i rt u ro R
e 6t gr - s r
c t
rE m
3 s/e) n one snoL a
3l 0 N3 e CoR nof(
S 1
- l 0t i
Ii
/
0i 2 x
& tt t st) 5 M7 G( E cn
- at r1 eAe reo6 1
.EEYE s
v G a e p1 OMTBN u
e A
ph e0 t
NAA O
a r
/
t eSR -
i NDDH C
P N
i r G
b T
EP bP ytE i
rnR h
KI EL h rt eU x
CN LE xonvN E
O U.
PT EfEE(
5 D
M t
d O
n C
e5 ne A
od
/
po N
mC o
m n
)
C amh o) n roti0i mcrnt a
aSf oc=l m8 r
mu p
ee ccd d nx td A
Si eseoE so
/
t uuRi(
S yC N
ll ano t
aamiirar N
S O
duuot ver e I
onnt newuh T
h aauoroDt C
tMMACpP( O U
e - - - -
M1234 5
6 D
e I
E 9
e 3
R 8
stt 9
nnr A
R 1
eeo
/
E cvp N
n W
e i E e o
O n
L R
i P
u t
J 3
a D
r n
N H
f o
i A
T o gt m
N nc A
a S
O dia
/
x N
M ot e N
E W
htR O
T t u e
)
)
D R
eh n n
s n
T O
MS w i
n i
U P
o a
e a
H E
D l
c l
S R
p ni p
x oL x
T 2
E i
E I
n A
t t&
(
(
N o
/
s c
U s
N ee i g r
a rT rn o
e u
ti r)
R l r snef n i o eivEi a
R ai a
F e rtll n
c yT a a p o) t ngr rnx i s A
nanort oE t r
/
enit osi(
au N
mel ati t pt el anar ro uH ninuurire D(
ouif gemeh s q a e e pd pt aEMRROAOO e-l A
RABCDEFGH e
/
2 p
N y
T de l
e d u t
A ed a
/
ce D
N rh oc FS A
.o
/
FS N
N I
l~
l
e. + 's '-
. REFUELING INFORMATION REQUEST 1.
Name of facility: Millstone 2 2.
Scheduled date for next refueling shutdown: Aucust 1990-3.
Schedule date for restart following refueling:
N/A 4.
Will refueling or resumption of operation thereafter require a technical specification change or other license amendment?
Not at this time 5.
Scheduled date(s) for submitting licensing action and supporting information:
l NONE-6.
Important licensing considerations associated with refueling, e.g.,
new or different fuel design or supplier, unreviewed design or performance analysis methods, significant changes in fuel design, new operating procedures:
l 1
Not at this time 7.
The number of fuel assemblies (a) in the core and 03) in the spent fuel storage pool:
(a)
In Core:
(a) 217 (b) 640 8.
The present licensed spent fuel pool storage capacity-and the size of any increase in licensed storage capacity that has been requested or is planned, in number of fuel assemblies:
Currently 1277 9.
The projected date of the last refueling that can be discharged to the spent fuel pool assuming the present licensed capacity:
1994, Spent Fuel Pool Full, core off load capacity is reached (without consolidation).
1998, Core Full, Spent Fuel Pool Full 2009, Spent Fuel Pool Full, core off load capacity is reached -
continoent upon full scale storace of consolidated fuel in the Spent Fuel Pool.
_ _ _ _ - _ _ - _ - _. - - _ _ _ _