Text
_
h' p-
,/y-f-
-. 4
""" 7 Log #-TXX-89252 I
Fi1e # 10110
.r C
903.9 NIELECTRIC
.Ref. # 10CFR50.55(e)'
May 8, 1989 W. J. Cabal i becutive Vice Premdent R
. U. S; Nuclear Regulatory Commission Attn: Document Control' Desk Washington, D.'
C.
20555 COMANCHE PEAK STEAM ELECTRIC STATION (CPSES)-
SUBJECT:
DOCKET N0. 50-445 DEFICIENT. MODIFICATION TO PIPE WHIP RESTRAINT SDAR:> CP-89-009l(INTERIM REPORT)
Gentlemen:
On April'.6,1989,:TV Electric verbally notified your Mr. S. P. Burris of a'
' deficiency involving the modification of a CVCS charging system pipe whip restraint. This is an interim report submitted on a potentially reportable condition under the provisions of 10CFR50.55(e).
Further evaluation is required to establish the safety significance'of this 4
potentially reportable deficiency.
TV Electric will submit the final' report on this issue prior to fuel load for Unit 1.
Sincerely, Willi m J gahill J r.
i By:
D. R. Woodlan Docket Licensing Manager c - Mr. R. D. Martin, Region IV Resident Inspectors, (CPSES) (3)
NV s
.TER f
I D 400 North Olive Street LB81 Dallas, Texas 75201
\\
l I
---._______-___-___--___-___-___A
_a_==----_--__-__-________-____-