__

Wiley Power Station

'n

. Shippingport. PA 150U-0004 Wdear Group i412) 643 5255 Pr n

. August 25,-1989 U. S. Nuclear. Regulatory Commission

' Attn:

Document Control Desk Washington, DC 20505

Reference:

Beaver Valley Power Station, Unit No. 1 and No. 2 BV-1' Docket No. 50-334, License No. DPR-66 BV-2 Docket No. 50-412, License No. NPF-73 Semi-Annual Radioactive Effluent Release Report for the First Six Months of 1989 Gentlemen:

The Semi-Annual Radioactive Effluent Release Report is hereby submitted in.

accordance with the requirements of Technical Specifications 6.9.1.12 and 6.9.1.13 for Beaver Valley Power Station-L

~ Unit' 1-license DPR-66 and Beaver Valley Power Station Unit'2 license-NPF-73.

This report..contains the information required by USNRC Regulatory Guide 1,21 revision 1

and the Technical Specifications.

Note that shared radwaste systems exist for gaseous elevated releases and for t

liquid releases.

The report format is summarized as follows:

1. Supplemental'Information Page 2.' Table 1A:

Gaseous Effluents - Summation of All Releases

3. Table 1B:

Gaseous Effluents - Elevated Releases

4. Table 1C1: Gaseous Effluents - Ground Level Releases (Unit 1)
5. Table IC7: Gaseous Effluents - Ground Level Releases (Unit 2)

[

6.. Table 2A:

Liquid Effluents - Summation of All Releases L

7. Table 2B:

Liquid Effluents l

8. Table 3:

Solid Waste and Irradiated Fuel Shipments

9. Table 4:

Lower Limits of Detectability

10. Table SA:

Assessment of Radiation Doses (Unit 1)

11. Table 5B:

Assessment of Radiation Doses (Unit 2) i l

12. Table 6:

Technical Specification Effluent Monitoring Instrumentation Channels Not Returned to Operable Status Within 30 days

13. Table 7:

40 CFR 190 Environmental Doses

14. Table 8:

Technical Specification Surveillance Deficiencies

15. Table 9:

Description, Justification and Concluding Statement for Unit 1 ODCM changes implemented ~on June 30, 1989

16. Table 10:

Description, Justification and' Concluding Statement for Unit 2'ODCM changes implemented on June 30, 1989

17. Joint Frequency Distribution (JFD) Tables bk

[

f I[

_______u_________._

_L__._____.__._____________________j

l Benysr Vollcy Powar Station,' Unit Non. f & 2 Docket No. 50-334, License No. DPR-66 Docket No. 50-412, License No.-NPF-73 Semi-Annual Radioactive Effluent Release Report for the First Six Months of 1989 Page 2 l

As specified by Technical Specification 6.9.1.13, attached to this-

{

report are complete copies of the current Unit 1 and Unit 2 ODCM2

)

that were revised on June 30, 1989 (as described in Tables 9 and 10).

j There were 4

abnormal releases (1 liquid and 3 gaseous) during.

this report period.

These releases were all determined to be within the Technical Specification Limits and D2 reporting was required per 10 CFR 50.72, 10 CFR 50.73, 10 CFR 20.403 and 10 CFR 20.405.

If there are any questions concerning th's report, please contact A. T. Lonnett at (412) 393-5860.

i Very truly yours, l

beh o/\\

J.

D. Sieber l

Vice President l

Nuclear Group j

Attachment cc:

with complete copy of ODCM's United States Nuclear Regulatory Commission l

Regional Administrator, Region I l

475 Allendale Road King of Prussia, PA 19406 cc: without copies of the ODCM's United States Nuclear Regulatory Commission Resident Inspector Beaver Valley Power Station 1

Ms. Dottie Sherman American Nuclear Insurers Library The Exchange Suite 245 270 Farmington Avenue Farmington, CT 06032 Mr. Thomas Gerusky Department of Environmental Resources Bureau of Radiation Protection P.O. Box 2063 l

Harrisburg, PA 17120 l

_ _ - - _ _ _ _ _ _ _ _ _ - - - _ _ _ _ _ _ _ _ _ _ _ _ _ - - _ _ _ _. _ - _ - _ _ _ _ _ - _ - _ _ _ _ _ _ _ _ - - -