ML20246F068

From kanterella
Jump to navigation Jump to search
Comments on Draft Technical Position on Postclosure Seals in Unsaturated Medium,Per Advisory Committee on Nuclear Waste 890426-28 Ninth Meeting
ML20246F068
Person / Time
Issue date: 05/03/1989
From: Moeller D
NRC ADVISORY COMMITTEE ON NUCLEAR WASTE (ACNW)
To: Zech L
NRC COMMISSION (OCM)
References
NACNUCLE, NUDOCS 8905120117
Download: ML20246F068 (2)


Text

NUCLEAR REGULATORY COMMISSION o

I ADVISORY COMMITTEE ON NUCLEAR WASTE

....+

May 3, 1989 The Honorable Lando W. Zech, Jr.

Chairman U.S. Nuclear Regulatory Commission Washington, D.C.

20555

Dear Chairman Zech:

SUBJECT:

DRAFT TECHNICAL POSITION ON POSTCLOSURE SEALS IN AN UNSATURATED MEDIUM During its ninth meeting, April 26-28, 1989, the Advisory Committee on Nuclear Waste (ACNW) met with members of the NRC staff to discuss the draft Technical Position on Postclosure Seals in an Unsaturated Medium.

Represen-tatives from the U.S. Department of Energy were present at this meeting.

We also had the benefit of the document referenced.

On the basis of this review, we offer the following comments:

1.

The draft technical position does not deal adequately with factors such as seismicity, tectonics, and long-term changes in geology, hydrology, and climate that might affect seal or barrier performance.

Long-term projections on the geology, seismicity, tectonics, and climate of the Yucca Mountain area contain uncertainties and each of these factors could have impacts on the design, location, and performance of the seals.

For these reasons, we believe that the draft technical position needs to be expanded to explicitly address these considerations.

2.

Backfill materials for shafts and seal cements for boreholes can be selected to have sorptive properties for radionuclides.

Such materials would provide added protection against unanticipated events, even if no containment functions are assigned to the backfills and seals.

We recommend that the draft technical position include a statement ad-dressing this additional consideration.

3.

The draft technical position indicates that the outflow of radioactive gases from the repository could be significant and needs to be pre-vented. We believe that a rationale to support this position should be provided, as well as some perspective on the significance of this potential release.

4.

Whether fracture or matrix flow predominates within the repository is an unresolved issue, and its resolution could have an impact on the method of control of potential releases.

Because fracture flow may prove significant, its potential impact on tne performance requirements for the barriers needs to be addressed in the draft technical position.

DW Q M $ h$ $

[

, =.

The Honorable Lando W. Zech, Jr. May 3, 1989 5.

It appears that the closures that the U.S. Department of Energy proposes to install in the Yucca Mountain facility might be better characterized as " barriers" rather than " seals."

If appropriate, the title of the draft technical position should be altered to reflect this fact.

The Committee wishes to express concern about the apparent lack of response from the geological community to which the draf t technical position was available for review.

The NRC should consider implementation of a more active program for soliciting reviews from such groups.

On the bssis of our review, we believe that development of the draft techni-cal position is justified. We hope these comments will be helpful.

Sincerely, Dade W. Moeller Chairman

Reference:

Memorandum dated March 31, 1989 from John J. Linehan, NRC, to Richard K.

Major, ACNW,

Subject:

Transmittal of Draft Technical Position on "Postclosure Seals in an Unsaturated Medium"

-__--.- _--- ___ - - -