ML20246F050
| ML20246F050 | |
| Person / Time | |
|---|---|
| Site: | Comanche Peak |
| Issue date: | 07/07/1989 |
| From: | William Cahill TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC) |
| To: | NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM) |
| References | |
| CP-87-109, TXX-89458, NUDOCS 8907130109 | |
| Download: ML20246F050 (1) | |
Text
-_
s#
k
EE Log # TXX-89458 1
~
File # 10110 r
=
917.1 1UELECTRIC William J. Cahill,Jr.
Executive Vice Preddent U. S.. Nuclear. Regulatory Commission Attn: Document Control Desk-Washington, D. C.
20555
SUBJECT:
COMANCHE PEAK' STEAM ELECTRIC STATION (CPSES)
DOCKET NOS. 50-445 AND 50-446 INAPPROPRIATE DEFICIENCY DOCUMENTATION SDAR: CP-87-109 (SUPPLEMENTAL REPORT)
Gentlemen:
.On February 11, 1988 TU Electric letter, logged TXX-88010, provided notification that the deficiency involving inappropriate deficiency documentation was reportable under the provisions of 10CFR50.55(e). The last report on this issue logged TXX-89049, was submitted January 31, 1989. This supplemental report is being submitted to update the corrective action completion schedule.
Unit I corrective actions for this issue have been rescheduled for completion by Unit 1. fuel load. The Unit 2 corrective action completion schedule remains unchanged.
Sincerely.
William J. Cahill, Jr.
ED By:
D. R, Woodlan Docket Licensing Manager DAR/vid c - Mr. R. D. Martin, Region IV Resident Inspectors CPSES (3)
[
k DO s
nn 400 North Olive Street LB B1 Dallas, Texas 75201
'b x-_.--._---_----__-
. - _ _ - - _ _