ML20246E045

From kanterella
Jump to navigation Jump to search
Requests That Proprietary WCAP-12305, Evaluation of Thermal Stratification for Seabrook Unit 1 Pressurizer Surge Line, Be Withheld,Per 10CFR2.790(b)(4)
ML20246E045
Person / Time
Site: Seabrook 
Issue date: 06/23/1989
From: Wiesemann R
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
To: Murley T
Office of Nuclear Reactor Regulation
Shared Package
ML19312B348 List:
References
CAW-89-083, CAW-89-83, NUDOCS 8907120075
Download: ML20246E045 (10)


Text

_-_

r,W, I(w L

e p

\\

p l.

i

- Westinghouse Energy Systems Bu 355 Electric Corporation.

Pittsburgh Pennsylvania 15230-0355 June 23, 1989 CAW-89-083

- Dr. Thomas Murley, Director

. Office of Nuclear Reactor Regulation

' U.S. Nuclear Regulatory Commission

. Washington, D.C.

20555 APPLICATION FOR WITHHOLDING PROPRIETARY INFORMATION FROM PUBLIC DISCLOSURE

Subject:

Transmittd of WCAP-12305 entitled:

" Evaluation of Thermal Stratification for the Seabrook Unit 1 Pressurizer Surge Line"

Dear Dr. Murley:

The proprietary material for, which withholding is being requested in the enclosed: letter by Public Service Company of New Hampshire is further identified in an affidavit signed by the owner of the proprietary information,.

. Westinghouse Electric Corporation. The affidavit, which accompanies this l

letter, sets forth the basis on which the information may be withheld from public disclosure by the Commission and addresses with specificity the considerations listed in paragraph (b) (4) of 10CFR Section 2.790 of the Commission's regulations.

~ The proprietary material for which withholding is being required is of the same technical type.as that proprietary material previously submitted as Affidavit CAW-88-129.

Accordingly, this letter authorizes the utilization of the accompanying affidavit by Public. Service Company of New Hampshire.

Correspondence with respect to the proprietary aspects of the application for withholding or the Westinghouse affidavit should reference this letter, CAW-89-083,'and should be addressed to the undersigned.

Very t uly yours,

/

g O

L'El Robert A. Wies /L0bKhv emann, Manager Regulatory and Legislative Affairs Enclosures cc:

E. C. Shomaker, Esq.

Office of the General Counsel, NRC 8907120075 890630 ADOCK 0500 3

{DR

PROPRIETARY INFORMATION NOTICE TRANSMITTED HEREWITH ARE PROPRIETARY AND/0R NON-PROPRIETARY VERSIONS OF DOCUMENTS FURNISHED TO THE NRC IN CONNECTION WITH REQUESTS FOR GENERIC AND/0R PLANT SPECIFIC REVIEW AND APPROVAL.

IN ORDER TO CONFORM TO THE REQUIREMENTS OF 10CFR2.790 0F THE COMMISSION'S REGULATIONS CONCERNING THE PROTECTION OF PROPRIETARY INFORMATION SO SUBMITTED TO THE NRC. THE INFORMATION WHICH IS PROPRIETARY IN THE PROPRIETARY VERSIONS IS CONTAINED WITHIN BRACKETS AND WHERE THE PROPRIETARY INFORMATION HAS BEEN DELETED IN THE NON-PROPRIETARY VERSIONS ONLY THE BRACKETS REMAIN, THE INFORMATION THAT WAS CONTAINED WITHIN THE BRACKETS IN THE PROPRIETARY VERSIONS HAVING BEEN DELETED.

THE JUSTIFICATION FOR CLAIMING THE INFORMATION S0 DESIGNATED AS PROPRIETARY IS INDICATED IN BOTH VERSIONS BY MEANS OF LOWER CASE LETTERS (a) THROUGH (g) CONTAINED WITHIN PARENTHESES LOCATED AS A SUPERSCRIPT l

IMMEDIATELY FOLLOWING THE BRACKETS ENCLOSING EACH ITEM OF INFORMATION BEING IDENTIFIED AS PROPRIETARY OR IN THE MARGIN OPPOSITE SUCH INFORMATION. THESE LOWER CASE LETTERS REFER TO THE TYPES OF INFORMATION WESTINGHOUSE CUSTOMARILY HOLDS IN CONFIDENCE IDENTIFIED IN SECTIONS (4)(ii)(a) THROUGH (4)(ii)(g) 0F THE AFFIDAVIT ACCOMPANYING THIS TRANSMITTAL PURSUANT TO 10CFR2.790(b)(1).

i l

I L:

J CAN-88-129 AFFIDAVIT STATE OF CALIFORNIA:

ss COUNTY OF GAN FRANCISCO:

Before me, the undersigned authority, personally appeared Robert A. Niesemann, who being by me duly sworn according to law, deposes and says that he is authorized to execute this Affidavit on behalf of Westinghouse Electric Corporation (" Westinghouse") and that the averments of fact set forth in this Affidavit are true and correct to the best of his knowledge, information, and belief:

0

'MME Robert A. Miesemann, Manager Regulatory and Legislative Affairs Sworn to and subscribed before me this f day of O & d o

,1988.

N 1

Notary Public

/

e

i r

- - CAW-88-129

~

(1)

I am Manager, Regui.o

  • .ra 8.egislative Affairs, in the Nuclear and' Advanced Technology Division, of the Westinghouse Electric Corporation and as such, I have been specifically delegated the function of reviewing the proprietary information sought to be withheld from public disclosure in connection with nuclear power plant licensing and rulemaking proceedings, and am authorized to apply.for its withholding on behalf of the Westinghouse Energy Systems, Nuclear Fuel, and Power Generation Business Units.

(2)

I am making this Affidavit in conformance with the provisions of 10CFR Section 2.790 of the Commission's regulations and in conjunction with the Westinghouse application for withholding accompanying this Affidavit.

(3) I have personal knowledge of the criteria and procedures. utilized by the Westinghouse Energy Systems, Nuclear Fuel, and Power Generation Business Units in designating information as a trade secret, privileged or as confidential commercial or financial information.

(4) Pursuant to the provisions of paragraph (b)(4) of Section 2.790 of the Commission's regulations, the following is furnished for-consideration by the Commission in determining whtther the information' sought to be withheld from public disclosure should be withheld.

(1) The information sought to be withheld from publie disclosure is owned and has been held in confidence by Westinghouse.

.__...--.._-_m_

m__._______.__m.____________._

l,

(...

CAW-88-129 - -*

4 (ii) The information is of a type customarily held in confidence by 4

Westinghouse and not customarily disclosed to the public.

Westinghouse has a rational basis for determining the types of j

information customarily held in confidence by it and, in that connection, utilizes a system to determine when and whether to hold certain types of information in confidence. The application of that system and the substance of that system constitutes Westinghouse poi:q' 'M provides the rational basis required.

Under that system, information is held in confidence if it falls in one or more of several types, the release cf which might result in the loss of an existing or potential competitive advantage, as follows:

(a) The information reveals the distinguishing aspects of a process (or component, structure, tool, method, etc.) where prevention of its use by any of Westinghouse's competitors without license from Westinghouse constitutes a competitive economic advantage over other companies.

(b)

It consists of supporting data, including test data, relative to a process (or component, structure, tool, method, etc.), the application of which data secures a competitive economic advantage, e.g., by optimization or improved marketability.

4,,

-4

? "-88-129

)

(c) Its use by a competitor would reduce his a.pinoiture of resources or improve his competitive position in the design, manufacture, shipment,1asta11ation, assurance of quality, or licensing a similar product.

(d) It reveals cost or price information, production capacities, budget levels, or commercial strategies of Westinghouse, its customers or suppliers.

(e) It reveals aspects of past, present, or future Westinghouse or customer funded development plans and programs of potential commercial value to Westinghouse.

(f)

It contains patentable ideas, for which patent protection may be desirable.

(g)

It is not the property of Westinghouse, but must be treated as proprietary by Westinghouse according to agreements with the owner.

There are sound policy reasons behind the Westinghouse system which include the following:

(a) The use of such information by Westinghouse gives Westinghouse a competitive advantage over its competitors.

It is, therefore, withheld from disclosure to protect the l

Westinghouse competitive position.

l

)

1

. 5

-E-CAW-88-129l h

i (b)

It is infomation which.4.urketable in' many ways. The extent to which such information is available to competitors diminishes the Westinghouse ability to sell products and services involving the use of the'infomation.

(c) Use by our competitor would put Westinghouse at'a j

I competitive disadvantage by reducing his expenditure of resources at our expense.

.(d) Each component of proprietary information pertinent to a particular competitive advantage is potentially as valuable as the total competitive advantage.

If competitors acqvf re components of proprietary information, any one componer,t may.be the key to the entire puzzle, thereby depriving

.i Westinghouse of a competitive advantage.

(e)~ Unrestricted disclosure would jeopardize the position of prominence of Westinghouse in the world market, and thereby give a market advantage to the competition of those countries.

(f) The Westinghouse capacity to invest corporate assets in research and devei@ ment depends upon the success in obtaining and maintaining a competitive advantage.

't

s.. CAW-88-129 m

(iii)

The information is being transmitted to the Commtssion in confidence and, under the provisions of 10CFR Section 2.790, it is.to be received in confidence by the Commission.

(iv)

The infomation sought to be protected is not available in-i public sources or available-information has not been -

previously employed in the same original manner or method ~

to the best of our knowledge and belief.

(v)

The proprietary information sought to be withheld:in this submittal is that which is appropriately marked in " South Texas Units 1 and 2, Pressurizer Surge Line and Residual Heat Removal Line Stratification", WCAP-12067, (Proprietary), for South Texas Projects Units 1 and 2, being transmitted by the' Houston Lighting and Power Company (HL&P) letter and Application for Withholding Proprietary l

Information from Public Disclosure, M. A. McBurnett,

~

Manager, Operations Support Licensing, HL&P, to NRC Document Control Desk, attention Dr. Thomas Murley, December, 1988. The proprietary information as submitted for use by Houston Lighting and Power Company for the South Texas Project is expected to be applicable in other licensee submittals in response to certain NRC requirements for justification of the integrity of the pressurizer surge line for its design life under thermal stratification.

conditions.

]

/,

I

)

+c CAW-88-129 This information is part or that which will enable Westinghouse to:

(a) Provide documentation of the analyses and methodology used in the evaluation of the thermal stratification phenomenon.

(b) Establish revised design transients for the pressurizer surge line based on plant monitoring data and Westinghouse test programs.

(c) Demonstrate the structural integrity of the pressurizer surge line for the 40 year design life, and the acceptability of leak before break and fatigue crack growth, under thermal stratification conditions.

(d) Demonstrate the low likelihood of stratification in the RHR lines, and the integrity of these lines in the event such a condition did exist.

~

(e) Assist the customer in obtaining NRC approval.

Further this information has substantial commercial value as follows:

(a) Westinghouse plans to sell the use of similar infomation to its customers for purposes of demonstrating adequate design life for surge lines and RHR lines.

(b) Westinghouse can sell support and defense of the technology to its customers in the licensing process.

i

4;fy'

, d. O '.

f ' ' ;.,.

- CAW-88-129

. n.

Public disclosure of this proprietary information is likely to cause substantial harm to the competitive position of Westinghouse because it would enhance the ability of competitors to provide similar analytical documentation and licensing defense services for cessnercial power reactors without commensurate expenses. Also, public disclosure of the information would enable others to use the information-to meet NRC requirements for licensing documentation without purchasing the right ta ese the information.

The development of the technology described in part by the information is the result of applying the results of many years of experience in an intensive Westinghouse effort and the expenditure of a considerable sum of money.

In order for competitors of Westinghouse to duplicate this

'information, similar technical programs would have to be performed and a significant manpower effort, having the requisite talent and experience, would have to be expended for the development,. verification, and ?icensing of adequate methods for evaluation of this phenomenon.

Further the deponent sayeth not.

i