. Nuclear Packaging, Inc.

ATTN:1.Dr. Charles'J. Temus 1010' South 336th: Street

Federal.Way, WA.98003-g-

. Gentlemen:-

' This: refers to. your. application dated February 27, 1989, requesting.a renewal

' of Certificate.of Compliance No. 9181 for the Model No. PAS-2 package.

In, connection with our review, we:need.the information identified in.the enclo-

'sure,to this' letter.: Additional. information requested by this letter should be submitted in the form of'revis'd pages.

e Please advise us within 30 days from the date of this letter when this informa-tion will be provided.: Lif. you have any questions regarding this matter, we would be. pleased to meet with you and your staff.

Sincerely, Original Signed by CHAEES E. MACDONALD Charles E. MacDonald, Chief Transportation Branch Division of Safeguards.

and~ Transportation, HMSS

Enclosure:

-As' stated Distribution::

-(MGTf/Gs PDR NMS$/StiTB r/f.-

GGardes-ERichardson pro 3>

HLee Clindner

' I

?

RChappell CMacDonald c

g Orc:ssTag

ssTec4:seleg
seTo
suTu Nhappe55bMac hkMEhhabes/lg:HLee
Clindner d:

lE~iisisiTWiif78sT5isisiT57i/Ki TTTHFT--~ ~ ?--

0FFICIAL RECORD COPY RENEWAL 9181

l l

,,1 Nuclear Packaging, Inc.

huPac PAS-2 Docket No. 71-9181 AUG I 51989 Enc 1 to Ltr dtd:

GENERAL INFORMATION DrawibgNo.X-107-500SPhasshownmanyoptionalmethodsofconstruction 1.

(i.e. Notes F, 3,4,14,15,16,18,and20). The application should show that the ability of the overpack to fulfill its intended purpose will not be affected by these optional con-tructions.

2.

Note 8 on Drawing No. X-107-500SP should be revised to reference that activities are to be conducted under an NRC approved Quality Assurance Program for. Pacific Nuclear Systems, Inc.

3.

Drawing No. X-20-220SP, Sh.1 of 4, should be revised to label the sample vial as the " secondary containment vessel" ar.d the sample shield as the

" primary containment vessel". The discussion of the containment vessels in Section.1.2 " Package Description" should be revised accordingly.

4.

Drawing No. X-20-220SP, Sh. 3 of 4, Section B-B should be revised to specify the thickness of lead between the bottom of the cavity and the bottom of the cask.

OPERATING PROCEDURES 1.

The discussion of freezing in Paragraph 7.1.5 should be deleted.

2.

Any additional required special tools should be identified in paragraph 7.2.1,2.

3.

The application should indicate a minimum period of time for the gas to flow to dry the passages in paragraphs 7.2.2.14, 7.2.3.9 and 7.2.3.13.

4.

Paragraph 7.2.3.3 describes a step in the emptying procedure but refers to paragraph 7.1.1 in the assembly process. The correct reference should be identified.

5.

The application should indicate a minimum period of time for the water to flow through the sample loop in Paragraph 7.2.3.8.

8.3 APPENDIX The appendix should state that the predetermined milliroentgen values used as acceptance criteria meet the requirements of 10 CFR 671.47.

QUALITY ASSURANCE Note that NRC approval No. 0192, Rev. 1 is no longer valid. Section 9.0 Quality Assurance should be revised considering the comment in item 2 under General Information above.