THE CLEVELAND ELECTRIC ILLUMINATING COMPANY P.O. BOX 97 5

PERRY, OHIO 44081 E

TELEPHONE (216) 259 3737 5

ADDRESS-10 CENTER ROAD FROM CLEVELAND: 241-1650 Serving The Best location in the Nation Al Kaplan PERRY NUCLEAR POWER PLANT vice entsaxur June 23, 1989 NUCLEAR GROUP PY-CEI/01E-0352 L PPIORITY R00TI M

)pTJL-irst Mr. A. Bert Davis M

[fl O

, v04 J y-ML Regional Administrator, Region III U.S. Nuclear Regulatory Commission g-799 Roosevelt Road

.no i

Glen Ellyn, Illinois 60137 nto son Perry Nuclear Power Plant Docket No. 50-440 Equipment Qualification

Dear Mr. Davis:

During discussions with members of your staff, CEI stated that additional information would be supplied covering Limitorque motor operator T-drains.

The attachment contains the safety evaluation of the Limitorque motor operators found during the recent inspections with missing T-drains, providing justification that the valves were operable during the first fuel cycle.

Based on the evaluations CEI has determined that the as found conditions did not affect plant or systems operability during the first fuel cycle. The T-drains will be installed in the valves prior to startup following the first refueling outage. Thic should resolve all the NRC's r.on._ erns with this issue.

Based on conversations with members of your staff, it is CEI's understanding that this is the final documentation presently requested by the NRC on the Equipment Qualification status.

If you have any questions, please feel free to call.

Very trul ur,

A, Al Kap an Vice President Nuclear Grcup AK:nje Attachment ec:

T. Colburn M. Kopp Resident inspector 8r07070234 890623

  1. 0%

P!)R ADOCK 05000440 W

-)

il

(

P PNU g