ML20246A914

From kanterella
Jump to navigation Jump to search
Discusses Util Participation in Emergency Response Data Sys. Completed Emergency Response Data Sys Communication Description & Survey Questionnaire for Plant Encl.Pwr Data Point Library Ref Files Being Compiled
ML20246A914
Person / Time
Site: Davis Besse 
Issue date: 06/29/1989
From: Shelton D
TOLEDO EDISON CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
1678, NUDOCS 8907070131
Download: ML20246A914 (11)


Text

l

./

L i

TOLEDO EDISON 7

Docket Number 50-346 A Centenw Enetw Conm License Number NPF-3 DONALD C. SHELTON voe rws.nent-Nder Serial Number 1678 June 29, 1989 United States Nuclear Regulatory Commission

' Document Control Desk Washington, D. C.

20555 Subj ect: Toledo Edison's (TE) Participation in the Emergency Response Data System Gentlemen:

Toledo Edissa has reviewed the Emergency Response Data System (ERDS) implemen'.ation questionnaire that was forwarded by Mr. John R. Jolicoeur of Office for Analysis.and Evaluation of Operational Data. Toledo Edison is available to participate in the ERDS Project.

A copy of tha completed "ERDS Communications Description and Survey Questionnaire" for the Davis-Besse Nuclear Power Station is attached for Nuclear Regulatory Commission (NRC) review. The " Pressurized Water Reactor (PVR) Data Point Library Reference Files" are being compiled and are expected to be completed within sixty days.

The Data Point Library Reference Files vill be available for discussion / evaluation during a site visit by the NRC ERDS Project Team.

If you have any questions regarding the ERDS Project for the Davis-Besse Nuclear Power Station, contact Mr. R. V. Schrauder, Nuclear Licensing Manager, at (419) 249-2366.

Very truly yours, KLB/dlm Attachment ec P. H. Byron, DB-1 NRC Senior Resident Inspector A. B. Davis, Regional Administrator, NRC Region III E. L. Jordan, Analysis and Evaluation of Operational Data q[

T. V. Vambach, DB-1 NRC Senior Project Manager

/

l.!)

8907070131 890629 PDR ADOCK 05000346 F

PDC THE TOLEDO EDISDN COMPANY EDISON PLAZA 300 MADISON AVENUE TOLEDO. OHIO 43652

'Dockei Wumber 50-346 Lf6ense Wumber NPF-3 derial Number.1678 j

'.Attschment j

Page 1 ERDS COMMUNICATIONS DESCRIPTION AND SURVEY QUESTIONNAIRE The following is a questionnaire pertaining to the Nuclear Regulatory Commission's (NRC) Emergency Response Data System (ERDS).

It consists of a series of cuestions concerning plant I/0-points, software protocols, data formats, transmission frequencies, and other plant computer specific information to De used in the ERDS computer database files.

Also, included here are descriptions and examples of data streams that the NRC is exoecting

'to see transmitted over the cmnnunication line.

l The purpose of collecting this data is to oevelop a olant specific catabase that will be retrievea into the ERDS once the system is activated by a i

l utility.

't will also be used' to oesign'and imolement ERDS software that can rece1ve tne utility's cata transmission.

In essence, this information will orovice tne basis for building a profile of the plant in tne ERDS datacase.

~

In some cases, the I/O point data may be distributed over several comcuters.

The ERDS considers this situation a multi-feeoer site and section IV must be filleo out for each feeder.

J i

i

)

i e

a[=

]

Docket Number 50-346

, License Eumber NPF-3 1

Serial Wumber 1678 j

. Attachment Page 2 l

I.

CONTACTS l

i l

Note: Please provide name, title, mailing address, and phone numoer.

l Survey Coordinator (i.e., contact for later clarification of question-l A.

naire answers):

Robert W. Schrauder, Nuclear Licensing Manager We request all contacts with the utility be made through the Survey Coordinator.

I B.

Computer Hardware Specialist (s)-

Richard K. Sharpe, Computer System - Engineer C.

Systems Software Specialist (s):

Richard A. Bast, Associate Computer Systems Analyst D.

Application-level Software Specialist (s):

N/A E.

Telephone Systems Specialist (s):

Linda K. Kusian, Telecommunication Services b

2-i l

b__

- _ _ _ _ _ = _ _ _.._

Docket: Number.50-346 W

,: License-Number NPF-3 Serial Number 1678 l

Attachment

.Page 3-II.- ERDS COMMUNICATIONS DESCRIPTION A.

Hardware The following hardware will be supplied:

-for a single feeder site:

Codex 2234 modem.V.22 2400 bps, asynchronous, autodialing, auto answer, error correcting, using the AT command

set, for a multiple feeder site:

Codex 6015 multiplexer, Codex.2260 modem - V.32 9600 bps, asynchronous, autodialing, auto answer, error correcting, using the AT command set.

B.

Software

i. Data Transmission Site will initiate a link request in ASCII using:

a.

-three character site designator

-the work LINK

-local site time and date in the format MM/DD/YY/HH:MM:SS.

~

b.

ERDS will respond in ASCII with:

-three character site designator

-the word ACCEPTED or DENIED.

I c.

Upon being accepted, the plant begins transmission of data at a fifteen second rate. The data string consists of:

header that identifies the site and date and time

-data packet sequenced with point identifier, value, and quality tag

-trailer containing the checksum value of the data packet.

... 1 l

[bbeketNUmber50-346-

~~

License Number WPF

  • Serial Number 1678-

?',

.. Attachment Page 4" 11.

Data format

.Two delimiters have been identified as follows:

-field delimiter (*)

-Data Set, delimiter (\\)

Link request. will be in ASCII as described in II.B.i.a. with each field a.

separated by a field delimiter and the request terminated with a data set delimiter.

Example, pal

  • LINK *01/12/89/11:48:50\\.

b.

ERDS response will be in ASCII as described in'II.B.i.b. with each field separated by a field delimiter and the response terminated with a

. data set delimiter.

Example, pal

  • ACCEPTED \\.

c.

Data stream will be in ASCII and will consist of three parts, header, data.. and trailer, as described in II.B.i.e. with each field separated by a field delimiter and each of the three parts separated by a data set delimiter.

Example, Header:

pal *01/12/89/11:50:30\\

Data:

B21CP004*-0.1234E+00*3*.....(for each parameter)\\

= Trailer:

56000\\.

d.

The following quality tags will be accepted by the ERDS:

-Good

=0 value is within range tolerance for discreet points, or input points are within tolerance for composed,,oints.

-Off-Scan

-1 point is currently out-of-service.

-Suspect

-2 value is not bad yet should not be considered good. This quality will occur primarily on composed values, when enough of the inputs are good to make the calculation yet a bad quality on other inputs may make the result questionable.

.a.

Docket Number?50-346-

.,-: License Humber-NPF.

, Serin 1 Number?1678-L Attachment;-

i;n Page 5

3ad

=J3' value is'not within tolerance for discreet' points, or calculation of a composed point <

may not.be made'due to the qualities"off its-inputs.

-Unknown

= 4 no quality indicator available

-Operator Entered = 5 value has been manually entered, overriding the discreet'or composed value.

'iii.

Protocol

.a.

EPDS will use XON/XOFF to stop, resume, or suspend data transmission for the site.

b.

Communication parameters:

-eight data bits

-1 stop bit

-no special parity. _ _ _ _ _.

Docket Numb'er 50-346 License Number NPF-3 Serial Number 1678

.. Attachment Page 6 iv.

E:teptions 1

Please note any exceptions which must be taken to section II and explain why.

None 6

Docket Number 50-346'

. License Neuber WPF-3 Serial Number 1678

-Attachment.

p e

.Page.7 I I I.' SELECTION OF DATA FEEDERS A,

.How many data feeders are there? (six maximum)

One.- DADS computer system

..8.

Identify the selected data feeders and provide the following for each:

.i L

(1) a short description of the categories of data points-it will provide (e.g.,, met, rad, or plant data points,. by unit) and-(2) the rationale' for selecting it if. another system can also provide its categories of. data points.

DADS computer system. All data points needed for the ERDS connection can be found on this system. This system also supports the SPDS software.

C.

Which data feeder is the site time determining feeder? This should be the feeder which'Is providing the majority of'the data points.

DADS

-1.

} -

_ = _ - _

g l Docket Number'50-'346' 1

,;?. License NumberfNPF-3 J

' 'Seric1 Number:1678-

.. Attachment

..Page 8 u

'IV.

DATA FEEDER INFORMATION Note: ; A new Section.IV must be filled out for each feeder' system selected.

A.

' General Questions-1.

Identification of data. feeder.

1 l

l-

-a.

What is the name in local parlance given to this data feeder (e.g.,

Emergency Response Information System)? 'Please give both the acronym 1

and.the words that form it.

'I.

DADS - The Data Acquisition and Dispiny System l-b.

Is this.the site time determining feeder?

Yes What is the update frequency of this feeder (in seconds)?

c.

Depends _on data l

Validyne - 1 second, net - 15 minute h

Analog - 30 second, Digital - 5 second ii. Hardware / sofa.are environment a.

Identify the manufacturer and model number of the data feeder hardware:

DEC VAX'11/785 b.

Identify the operating system.

VMS l

What method of time-keeping is implemented on this feeder system (Day-C.

light Savings, Standard, Greenwich)?

Day-light savings d.

-In what time zone is this feeder located?

Eastern Standard j

l 8-

T liocketAumber30-346 T License Number 'NPF-3

[.

~ 'Seria1 Number 1678 L

1

.i Attachment-Tage 9 iii. Data' communication details p

a.

Can this data feeder provide asynchronous serial' data communication (RS232C)_with full modem control?

Yee b.

Will this feeder transmit in ASCII or EBCDIC?

ASCII-c.

Can this feeder transmit at a serial baud rate of 2400 bps?. If not, at

.what. baud rate can.it transmit?

Yes d.

Does the operating system support XON/X0FF flow control?

Yes I '.

Are there any problems foreseen in the NRC using XON/XOFF to

. control transmission of data?

No e.

If it is not feasible to reconfigure a serial port for the ERDS linkup (i.e., change the baud rate. parity, etc.), please explain why.

N/A f.

Can the serial port dedicated to EROS be configured so that the NRC need not emulate a specific brand of terminal (i.e., can it be con-figured to be a " vanilla" terminal)?

Yes

.g.

Serial Number 1678

-Attachment.

. Page 10 -

. gp Do any ports currently exist for the EROS linkup?

.Yes.

1.

_ If not, is it possible to add additional parts?

Yes

2.

> If yes, will the port be used solely by ERDS or shared with other

.non-emergency-time users? 'Give details.

Port"will be dedicated to ERDS iv. Data' feeder physical environment and management a.

Where is the data feeder located in terms of.the TSC, EOF and control room?

DADS.is located in the administration building next to the TSC.

1 b.

Is the data feeder protected from less of supply of electricity?

Yes.

c.

Is there a human operator for this data feeder?

Yes-1.

If so, how many hours a day is the feeder attended?

9 hours1.041667e-4 days <br />0.0025 hours <br />1.488095e-5 weeks <br />3.4245e-6 months <br />