Final Deficiency Rept CP-89-020 Re Limitorque Actuator Mounting Bolts.Initially Reported on 890717.Deficiency Could Not Have Adversely Affected Safe Operation of Plant & Issue Determined Not Reportable
ML20246A175
Person / Time
Site: Comanche Peak  
Issue date: 08/16/1989
From: William Cahill
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
CP-89-020, CP-89-20, TXX-89603, NUDOCS 8908220393
Download: ML20246A175 (1)


Text

7

^

- gc p!

~

F EE Log # TXX-89603 n

File # 10110

~

903.9

=

r NELECTRIC August 16, 1989 j

Esecutiw Yitt heskient ^

U. S. Nuclear Regulatory Commission Attn:. Document' Control Desk Washington, D. C.

20555

SUBJECT:

- COMANCHE PEAK STEAM ELECTRIC STATION (CPSES)

DOCKET NOS. 50-445 AND 50-446 LIMITOROUE ACTUATOR MOUNTING BOLTS SDAR: CP-89-020 (FINAL REPORT)

Gentlemen:

On; July 17, 1989.. TU. Electric verbally notified the NRC of a deficiency

' involving Limitorque actuator mounting bolts. After further evaluation, it was concluded that this condition is not reportable under the provisions of IOCFR50.55(e).

Limitorque actuator mounting bolts are required to meet the material specification of ASTM A193 Grade BBM. A walkdown determined that the bolts

' installed in the field are not marked "B8M" on the head of the bolt as required by ASTM. The installed vendor supplied bolts were found to be inscribed with the number 316 which is not a recognized symbol for any type or grade of standard bolting.. This condition was documented on nonconformance reports.

Six bolts were removed from two Unit 2 Limitorque actuators and were destructively tested. The test results indicate that the bolts meet the chemical composition and mechanical properties specified per ASTM A193/A193M-

87. Grade B8M.

Based on these test results, in the event this deficiency had remained uncorrected, it could not have adversely affected the safe operation of the. plant, and~therefore this issue is not reportable.

Sincerely.

William J. Cahill, Jr.

8908220393 890816 By:

PDR ADOCK 05000445 D. R. Woodlan s

PDC Docket Licensing Manager DJE/smp c - Mr. R. D. Martin, Region IV g,f Resident Inspectors, CPSES (3) p