Notice of Violation from Insp on 890410-14.Violation Noted:Failure to Control Welding Activities by Qualified Personnel Using Qualified Procedures
ML20245J467
Person / Time
Site: Cooper 
Issue date: 05/01/1989
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To:
Shared Package
ML20245J457 List:
References
50-298-89-15, NUDOCS 8905040136
Download: ML20245J467 (2)


Text

,

(t [ g i

i

.. y y

m

r. :,

Ni.

J x

4 APPENDIX A' NOTICE'0F'IOLATION V

-Nebraska Public Power District Docket: 50-298 O

' Cooper Nuclear Station License: DPR-46' l'

During an NRC inspection conducted on April 10-14,1989,'a.violationof$RC l

requirements was identified. The violation involved failure to control welding' activities.

In accordance with the " General Statement of Policy and Procedure for NRC Enforcement Actions," 10 CFR Part 2, Appendix C (1988), the violation -

isLlisted below:

4 Criterion IX of 10 CFR Part 50 Appendix 8 specifies that measures shall be-

' established to assure that welding is' controlled and accomplished by 1

qualified personnel using qualified procedures in.accordance with applicable codes. and other special requirements.

-l

. Contrary to the'above.

)

.a.

Maintenance Procedure No. 7.7.15' does not control-the heat input within the limits qualified as required by ASME Section IX 1983 Edition for welding materials requiring impact properties'.

b.

The postweld heat' treatment specified in Maintenance Procedure

(

No. 7.7.16 was>not qualified by the supporting ~ Procedures 4

qualification Report (PQR) as' required by' ASME Section IX,

.Radiogfaphicexaminatio'nreports, 173-98061-2 and 173-98061-5, for 1

.c.

double wall radiography of two welder performance qualification tests' j

1 recorded that the penetrameters were placed source-side inside the~

1 pipe although the radiographic procedure'specified placement of the~

penetrameters source-side and outside the pipe.

i d.

EHolding ovens containing'E7018 electrodes were outside the temperature i

range specified in Maintenance Procedure No. 7.7.3.2, and the' temperature was not being checked daily as required ~by the procedure, j

e.

The temperature range of 150-200"F, specified in Maintenance Procedure No. 7.7.3.2 for electrode holding ovens does not comply with AWS t

D1.1-85, which states that E7018 electrodes shall be heated to at 1

least 250 F.

l j

.c This is a Severity Level IV violation. (Supplement I)(298/8915-01) i I

l1 l

1 I

L EfP 2h!h 8s888 be

{

PDC l

Q 1

e ':

. Pursuant to the provisions.of 10 CFR 2.201, Nebraska Public Power District is hereby required to submit a written statement or explanation to this Office within 30 days of the date of the letter transmitting this Notice. -This reply.

- should include for each violation:

(1) the reason for the violation if admitted, (2)-the corrective steps that have been taken and the results achieved, (3) the corrective steps that will be taken to avoid further violations, and (4) the o

date when full compliance will be achieved. Where good cause is shown, consideration will be given to extending the response time.