4 APPENDIX A' NOTICE'0F'IOLATION V
-Nebraska Public Power District Docket: 50-298 O
' Cooper Nuclear Station License: DPR-46' l'
During an NRC inspection conducted on April 10-14,1989,'a.violationof$RC l
requirements was identified. The violation involved failure to control welding' activities.
In accordance with the " General Statement of Policy and Procedure for NRC Enforcement Actions," 10 CFR Part 2, Appendix C (1988), the violation -
isLlisted below:
4 Criterion IX of 10 CFR Part 50 Appendix 8 specifies that measures shall be-
' established to assure that welding is' controlled and accomplished by 1
qualified personnel using qualified procedures in.accordance with applicable codes. and other special requirements.
-l
. Contrary to the'above.
)
.a.
Maintenance Procedure No. 7.7.15' does not control-the heat input within the limits qualified as required by ASME Section IX 1983 Edition for welding materials requiring impact properties'.
b.
The postweld heat' treatment specified in Maintenance Procedure
(
No. 7.7.16 was>not qualified by the supporting ~ Procedures 4
qualification Report (PQR) as' required by' ASME Section IX,
.Radiogfaphicexaminatio'nreports, 173-98061-2 and 173-98061-5, for 1
.c.
double wall radiography of two welder performance qualification tests' j
1 recorded that the penetrameters were placed source-side inside the~
1 pipe although the radiographic procedure'specified placement of the~
penetrameters source-side and outside the pipe.
i d.
EHolding ovens containing'E7018 electrodes were outside the temperature i
range specified in Maintenance Procedure No. 7.7.3.2, and the' temperature was not being checked daily as required ~by the procedure, j
e.
The temperature range of 150-200"F, specified in Maintenance Procedure No. 7.7.3.2 for electrode holding ovens does not comply with AWS t
D1.1-85, which states that E7018 electrodes shall be heated to at 1
least 250 F.
l j
.c This is a Severity Level IV violation. (Supplement I)(298/8915-01) i I
l1 l
1 I
L EfP 2h!h 8s888 be
{
PDC l
Q 1
e ':
. Pursuant to the provisions.of 10 CFR 2.201, Nebraska Public Power District is hereby required to submit a written statement or explanation to this Office within 30 days of the date of the letter transmitting this Notice. -This reply.
- should include for each violation:
(1) the reason for the violation if admitted, (2)-the corrective steps that have been taken and the results achieved, (3) the corrective steps that will be taken to avoid further violations, and (4) the o
date when full compliance will be achieved. Where good cause is shown, consideration will be given to extending the response time.