Revises Util 880802 Response to Generic Ltr 88-01, NRC Position on IGSCC in BWR Austenitic Stainless Steel Piping. NRC Positions on IGSCC Will Be Incorporated Into Inservice Insp Program
ML20245J400
Person / Time
Site: Limerick  
Issue date: 04/28/1989
From: Hunger G
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
GL-88-01, GL-88-1, NUDOCS 8905040120
Download: ML20245J400 (2)


Text

.

.ex:..o y

GL 88-01

~

i PHILADELPHIA ELECTRIC COMPANY j

2301 MARKET STREET P.O. BOX 8699 PHILADELPHIA. PA.19101 (216)8414000 April 28, 1989 Docket Nos. 50-352 50-353 License No. NPF-39 Construction Permit No. CPPR-107 l

U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20S35

~

SUBJECT:

Limerick. Generating Station, Units 1 and 2 Revised Response to Generic Letter 88-01, "NRC Position on IGSCC in BWR Austenitic Stainless Steel Piping"

REFERENCE:

Letter from S. J. Kowalski (PECo) to F.

J. Miraglia, Jr. (NRC) dated August 2, 1988

Dear Sir:

The purpose of this letter is to revise our response ~to Generic Letter 88-01, Item 3, which requests that licensees propose a change to their Technical Specifications to include a statement in

'the section on Inservice Inspection (ISI) that the ISI Program for piping covered by the scope of the Generic Letter will be in conformance with the staff positions on schedule, methods and

~

. personnel, and sample expansion.

In the referenced letter, Philadelphia Electric Company (PECo) committed to request a change

. to the Technical Specifications to include the statement recommended by the Generic Letter.

PECo also committed to revise the Final Safety Analysis Report (FSAR) by February 28, 1989 to include the recommended statement.

This revision to the FSAR was issued in October, 1988 (Rev. 54).

However, upon review of other licensees' responses to Item 3, and subsequent discussions with the Lead NRC Project Manager for this Generic Letter, we have concluded that inserting the recommended statement into the Technical Specifications is not I

necessary or appropriate.

As stated in our response to the Generic Letter, the staff positions on intergranular stress corrosion 8905040120 890428 A047 PDR ADOCK 05000352 i

P PDC I

l a

Document Control Desk April 28, 1989 Page 2 cracking (IGSCC) will be incorporated into our ISI Program document.

This position is consistent with the philosophy of the Technical Specifications Improvement Program which encourages the relocation of various specifications to other licensee controlled documents.

Therefore, this letter amends our original response to Item 3 of Generic Letter 88-01 by withdrawing our commitment to propose an amendment to the Technical Specifications concerning our ISI Program.

If you have any questions concerning our revised response, please do not hesitate to contact us.

Very truly yours, 0-feh.

}

G.

A.

Hunger, Jr.

Director Licensing Section Nuclear Support DivisAon cc: