ML20245F786

From kanterella
Jump to navigation Jump to search
Discusses Safety Insp Rept 70-0882/89-01 on 890512 & Forwards Notice of Violation
ML20245F786
Person / Time
Site: 07000882
Issue date: 06/16/1989
From: Kinneman J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Lidofski L
COLUMBIA UNIV., NEW YORK, NY
Shared Package
ML20245F791 List:
References
NUDOCS 8906280242
Download: ML20245F786 (2)


Text

_-

34 JUN 161988 Docket No.- 070-00882 License No. SNM-870

. Columbia University.in the City of New York ATTN:

Leon'Lidofski' Radiation Safety. Committee Chairman 1

'289 Engineering Terrace New York, New York 10027 Gentlemen:

Subject:

Routine Inspection No. 070-00882/89-001 On May 12, 1989, Richard B. Provencher of this. office conducted a routine safety, f

inspection at the. above address of. activities authorized by the above listed NRC

{

license. --The inspection was an. examination of your licensed activitie's as they relate to radiation safety and to compliance with the Commission's regulations andLthe license conditions'. The inspection consisted of observations by the inspector, interviews _with personnel, and a selective examination of representa-tive records.. The findings of the. inspection were discussed with!Stuart Morowitz and Alex Voxakis of your staff at the conclusion of the inspection.

Based on the results of. th'is inspection, it appears that your activities were not conducted in full. compliance with NRC requirements. A Notice of Violation is enclosed as Appendix A and categorizes each violation by severity level in.

accordance with the " General Statement of Policy and. Procedure for NRC Er. force-ment Actions," 10 CFR Part 2, Appendix C (Enforcement Policy). You are required to respond to this letter and in preparing your response, you should follow the instructions in Appendix A.

In accordance with Section 2.790 of the NRC's " Rules of Practice," Part 2,'

Title 10,' Code of Federal Regulations, a copy of this letter and your reply will be placed in the'Public Cocument Room.

1 The responses directed by tMs letter and the accompanying Notice are oct

{

subject to the clearance precedures of the Office of Management and Badget

.q as required by the Paperwork Reduction Act of 1980, PL 96-511.

4 1

1 I

t 0FFICIAL RECORD COPY ML DL COLUMBIA - 0001.0.0

(

i 06/14/89

)

l h*

j

.8906280242 890616 RETURN ORIGINAL TO PDR ADOCK 07000882 l.

C PDC ggioy I i

i

g,
y' Columbia University'.in the 2.

City of New York

Your cooperation with us is appreciated.

Sincerely, Original Signed Dr John D.-Kinneman

.' John D. Kinneman, Chief Nuclear Materials Safety Section B Division of-Radiation Safety and Safeguards

Enclosure:

. Appendix A, Notice of Violation cc:

Public_ Document Room (PDR)

Nuclear Safe'ty Information Center (NSIC)

City of New York-Ahmad Hatami, Radiation Safety Officer-

.Stuart Morowitz, Director of Environmental Health & Safety bec:

Region.I Docket. Room (w/ concurrences)

Management Assistant,.DRMA R. B. Provencher, RI RI:

S Provencher/bc I lnneman 06/[f/89 06/%/89 0FFICIAL RECORD COPY ML DL COLUMBIA - 0002.0.0 06/14/89 u___ _ z __ __

.