ML20245F701

From kanterella
Jump to navigation Jump to search
Withdraws 890316 Request for Relief from Hydrostatic Testing 3-inch Check Valve After Replacement of Cap,Per Inservice Insp Program Requirements
ML20245F701
Person / Time
Site: North Anna, 05000399  Dominion icon.png
Issue date: 04/23/1989
From: Cartwright W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
89-182A, NUDOCS 8905020467
Download: ML20245F701 (2)


Text

- __- ____.

)

- /

VIRGINIA MI,ECTHIC AND PO WER COMI*ANY R ICIIM ON D, VI HO INI A 20 2 61 1

w. n.ciarwu'""'

April 23, 1989 Vaca Punstr> mar N ere s.na m U. S. Nuclear Regulatory Commission Serial No.

89-182A Document Control Desk PES /ISI/DJF:

i Washington, D.C. 20555 Docket Nos.:

50 339 License Nos.:

NPF-7 Gentlemen:

VIRGINIA ELECTRIC AND POWER COMPANY NORTH ANNA POWER STATION UNIT 2 INSERVICE INSPECTION PROGRAM WITHDRAWAL OF SUBMITTED RELIEF REQUEST in our letter of March 16,1989 (Serial No.89-182), we requested relief from hydrostatically testing a 3-inch check valve, 2-FW-134, after the replacement of its bolted cap, due to this valve being unisolable from the Unit 2 "C" steam generator. On April 12,1989, a telephone conversation was held between Mr. George Johnson of your staff and Mr. David Fortin of our staff to discuss the requested relief.

i Mr. Johnson stated that because the replacement cap was attached by.a bolted connection (i.e., not requiring welding to the pressure boundary) a hydrostatic pressure test was not necessary for the replacement and a system leakage test would be adequate to satisfy the post-replacement testing requirements. Therefore, the request for relief was not necessary in this particular instance.

Accordingly, we withdraw our relief request concerning the hydrostatic pressure testing 'of this valve.

If you have any questions or require further information, please contact us.

Very truly ours, W. R. Cartwright i

8905020467 890423 ADOCK 050 g 9 gpy7 DR I t j

l

r a

' cc:

U. S. Nuclear Regulatory Commission 101 Marietta Street, N.W.

Suite 2900 Atlanta, GA 30323 Mr. J. L. Caldwell NRC Senior Resident inspector North Anna Power Station i

_ _ _ _ _. _ _ _ _. _ _ _ _ _ _ _.. _ _ _ _ _. _ _ _ _