ML20245E620

From kanterella
Jump to navigation Jump to search
Forwards Operating Limits Rept Utilizing K(Z) Figures in Present Tech Specs.W/O Encl
ML20245E620
Person / Time
Site: Byron  Constellation icon.png
Issue date: 08/03/1989
From: Chrzanowski R
COMMONWEALTH EDISON CO.
To: Murley T
Office of Nuclear Reactor Regulation
References
0236T:1, 236T:1, NUDOCS 8908110299
Download: ML20245E620 (7)


Text

- _ _- - - - _-- _ - _ . --_- -_ - - _ _ - _ _ _

~

' +

J 'Camm:nwrith Edison 72 West Adams Street, Chicago, Illinois

.k- 1V' ; Address Reply to: Post Office Boi7BT Ohicago, Illinois 60690 - 076/ .

August 3, 1989 Dr. Thomas E. Murley, Director i Office of Nuclear Reactor Regulation  !

U.S. Nuclear Regulatory Commission Washington, DC '20555

Subject:

Byron Station Units.1 and 2 Operating Limits Report NRC Docket Nos. 50-454 and 50-455  !

l l '

References:

(a) -December 4, 1987, letter from K. A. Ainger to T. E. Murley (b) March'2, 1989, letter from R. A. Chrzanowski to T. E. Hurley (c). March 28, 1989, letter from L. N. 01shan and  :

S. P. Sands to H. E. tiliss 1

Dear Dr. Murley:

Reference (c) acknowledged approval of the Byron Technical Specification Amendment that removed the fixed Fxy limits from the Technical Specification and replaced it with the requirement to submit an Operating Limits Report. Reference  ;

(b) provided the Operating Limits Reports for Byron Units 1 and 2. However, these..' l reports were calculated utili_ zing the K(Z) figures from the proposed amendment  !

from reference (a). The' Attachments to this letter provide the Operating Limits Reports for Byron Units 1 and 2 utilizing the K(Z) figures'in thte present l Technical Specifications. -This correction is strictly administrative in nature and has no technical or safety impact since the previous fixed Fxy limits and.the '

j revised Operating Limits Reports reninded satisfied. {

.l (he Attachments to this letter will remain valid until the proposed  :

a'nendment from reference (a) is approved. At that time, the Operating Limits l Reports from reference (b) will be utilized. :j

l Please direct any questions regaroing this matter to this office. l l

Very truly yours,  !

g oa i

R. A. Chrzanowski  ;

Nuclear Licensing Administrator l 0236T:1 cc: Byron Resident Inspector L. N. Olshan - NRR Region'III Office Office of Nuclear Facility Safety - IDNS

"~

8908110299 090803 ' d I l PDR ADOCK 05000454 P PNV ,

j 'i

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ________ __ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ .