ZION NUCLEAR POWER STATION ANNUAL OPERATING REPORT.
1988 NRC DOCKETS 50-295 AND 50-304 COMMONWEALTH EDISON COMPANY l
i l
l f
fA Obh 0 eo R
qoc i
l 1102t(2)
\\
TABLE OF CONTENTS 1.
Environmental, Radiological and Meterological Monitoring Reports II. Haukegan Memorial Airport Expansion Plans III. Annual Occupational Exposure Data IV. Challenges to Primary System PORV and Safety Valves i
l f
1102t(3)
L - --- -
l v
i I.
EDYironmental. Radiological and Meterological Monitoring Reports:
1 These;tre submitted under separate cover by Environmental Affairs.
l II. Haukeaan Memorial Airport Expansion Plans:
The airport master. record (FAA 5010-1 Report), and airport map (FAA 5090 i
Report) has been updated and submitted by the Haukegan Port Administrator.
The airports. environmental impact assessment report, submitted in 1978 has been approved.
III. Annual Occupational Exposure Data Personal Radiation Exposure Data per Reg. Guide 1.16 is reported under separate cover by the Health Physics b partment.
IV. Challenges to Primary System PORV and Safety Valves:
There were two occurrences of Pressurizer Power Operated Relief Valve (PORV) actuation in 1988. One actuation occurred on March 29, 1988.
During periodic testing of Safeguards Actuation, an inadvertent phase A Conta'wnt Isolation occurred, resulting in isolation of instrument air to Containment. During a subsequen' ramp down in power, both PORV's lifted and reseated due to the loss of air to Pressurizer Spray Valves.
This event is documented in License Event Report (LER) 304/88-003-00.
A second incident of PORV actuation occurred on Zion Unit 2 on December 11, 1988 while performing modification testing under Technical Staff Special Procedure (TSSP) 148 @ after an inadvertent Safety Injection.
All components actuated as required.
Primary system pressure was properly maintained by the PORV's during the SI.
Since the unit was in cold shutdown there were no adverse thermal effects on the plant piping.
This event was reported as LER 304/88-012-00.
The health and safety of the public were not affected by the items described in this report.
1102t(4)
6 1
s.
4 f lA A.. 8'y
- y 95 W#
Waukeean Port D. trict
- Waukegan Regional Airport is Port of Waukegan Fa.bruary 27, 1989 Richard Sorrentino Commonwealth Edison Zion Generating Plant Zion, IL 60099
Dear Mr. Sorrentino,
The attached information was sent to me by the F.A.A.
I believe this will meet your needs.
As you will note,'he 5090 report is the actual map of the t
airport; the 5010-1 report is the Airport Master Record. Another change is that Mr. Denison is no longer Airport Manager, and at
- this time Mr. Al Huisman is the Acting Airport Manager.
Sincerely, i
'l 3,
.n-.
Mary Walke'r l
l --
l l
i A::ministrative Offices
- 0312,244-3133 55 South Harbor Piace P O Bon 620
- Waumegan Hiinois 60079 L--___-___
- U.S. DEPARTMENT OF TRANS'ORTATION
,i.
g FEDERAL AVIAVION ADMWISTRAVION' ROUTE 'allP 2-22-89
' " " ~ " ' " ' '
. To:
Ms. Mary Nalker
]
FOR TOUR $1GNATURE PER YOUR REQUEST FOR YOUR INFORMATION COMME NT PER OUR CONvtR$ATION TAKE APPROPRIATE ACTION NOT! AND RfTURN PLEA $E ANSW!R DISCUSS WITN Mi PatPARE REPLY FOR SIGNATURE FOR YOUR APPROVAL OF REMARKS:
Attached is a copy of the latest revisions to the FAA Form 5010-1 Airport Master Record for Waukegan. The printed copies we will receive shortly will have the same information. As soon as we receive those copies, I will send you a clean print.
Thank you!!!
Attachment FROM:
Susan Ewing
~b; i
'}
~
-)
v s oee atws=t oe vaasseoavatio%
AIRPORT MASTER RECORD 3,,C d3/7a/ 4 PRINT AT esosw aviow aouwstaatio=
m..,
4
>l ATIl ITY: Cc!CAG;/.AunC6Ah
- STA.
IL FAA $ 1 T C *.R : 74553 A
> 'Aggee=T.NamC: wAuxCFsN RCG!ChAL.
5 COUNTT: LAKC !L 2 C'O TO AIRPORT (N'3: 35 1 4 R !G / A C O : AGL /CH I 7 $CCT ACR0 CMT: CHICAGO
.j
. 6 A tCO AIRCR AF', j' 1
3CNC A AL SC8VICCT 11 s.NC15e18: 8biLIC
>T? FLCL: 1Jr '0441 &
91 1196 L C t'.G : L&J
-1
>11 f.NtR: kauxC;AN sC87 OISTRICT
' >71 AIRFRAMC RPR$: 'AJ04 11 'LLTI CNG: s7 32I
>12 A00PC*5: P9 805 62f
>72 PWP PLANT R8*5: MAJOR 92 JET:
j9 scl bAUMCGAN IL 6RB79 47! 'OTTLC 0xTr,Ct.:p,,m1GM
{
- nTAL s*=n fgg
>13 S MONI N R: 31?-2=a 3133-
>76 tuLK 0xvnCN:
A
>14 "ANLGCR:
Ro be rT M. 0& a n a s.a 75 TsNT STORAGE: Tfr.ast 93 eCLIC:PTCes:
2l
.>1? 40D h!$ $ : P 3 907 327Jsst E piaCafeo de 75 OTFER SC# VICES: CPTR 9a SL :g t e,5 :
.g; ksVKCsAN T L 6 P 5 34 f 7 RNTL SAL!S INSTR,$.r#.
95 r!LITARY:
i
>16 *n0NC NR: 312-246-f855 Avryt $,
96 LLisA.L]GnT:
1 Dif A TTEND ANCE ScrCOVLC:
M)NTM5 04YS NCLR!
1 ALL AL L ALL FACILITIES OPC4 AT10?as
'I
>88 ARPT PCN: CG 185 Al* CA8'!C#:
18 A !R F )R Y USC:
- USL?
>*1 APT LCT $ECO:*0USW 0 Awn' iti Co*PUTC8:
42-25-1%g,h.TN$URVCYC0
>#2 UNICOPt.!!3 888 172 AIR TAxt:
1234; 19 ARPT L A T:
23 ARPT LCNG: 26 ?-12 -#cszk / 44 De! h!NO Ih0!CATGR; VCS 123 G A L3 CAL:
74236
- ) ARPT.CLCV
- 727
$URVCYCC se $rGMCP.TCO CIRCLC: NONC 1s* S A ITN#47:
- a796 22 ACRE AGE :
ess g,gy. jf 8' CONT *CL Tht: NO IPS *ILITA'Y:
189
!!f43PI l
>23 alGaf TRAFFIC: N3 Pa F$3: MANKAECC TOTAL:
- 22. NON-Comm LAN0tNG <CC: vC s a7 ess ON 4.PT: u0
- GY 48 FL$ PPCNC NR: <-935.*f71 CPCt ATIONS F DR 12 -
25 N ASP /F COCR AL 4GR C C* C tat :
26 'AR 139 INCC#: N 89 TOLL FRCC k': 1-588-322-1552
- 05 CNOINS 33NOV86
]
E JN h a Y DATA
>38 RUNWAY ICCMT 31/23 16/32
>31 L!NGIN:
prF3 37!1
>!? '.10'4:
l'2 7"
>!3. 5 yh r T Y PC.CC'd C O N C r,
C ON C a4
>3a typF T A C AT=CNT f%./ A, ges c.,
35 3R0:5 ef: 5.
95 16 l
36 (19 T%$05) th 12f 23
?
17.
CT.
??t l
18 CCT.
i t
LIGHT!uG/APCe A l' t 75/23 to/32 l
====.....*
1st COGC INTCNSITY HIGH "CC
[
- 1 NOW !LEPCNT F1 p
p
) 2 RWY
- A*K TYPC-CONO NPI-G /M81-0 B SC -F /t S C 4L
/
/
/-
263 VASI va t
/ val Vat
/N
/
/
/
+4 inR CRCSSING HGT ST
/38 3r
/
/
/
/
e5 v!SU AL GLIOC ANGLC 3.as
/ 3. *s 3.tr !
/
/
/
p*6 C$TRLN T02 N-N
/N-A th-N
/
/
/
547 RVR.RVV N.N
/9.N N.N
/N.N
/
/
/
>*8 RCIL d* /
/ #
/N
/
/
/
>a9 APCM LI GH T S
/ jngg $ g
/
/
/
/
0957RUCTICN C ATA 8t/23 le/32 15 FAR TT CATCnePy P(V) /s //g etV
/etV3
/
/
/
>t1 DISPLACC0 The gjg /
es44$6/
/
/
/
>?2 CTLS 085TN f p CL S / 444/0 RCAO /TRCC
/
/
/
>53 065fN P ARRCD/LGTL 4/
/ /V 4/ / /V
/
/
/'
>to nGT Ae0VC Rb7 CNC 39
/
15
/38
/
/
/
>t5 0!$7 FROM RhY CNn' 689
/
245
/12tf
/
/
/
>t6 CNT ALN OF F SE Y SP6L /
12*R
/65L
/
/
/
l 17 065fN CLNC SLOPC lt:1 /te:1 f *8:1
/35:1
/
/
/
SS CLD:!*!N 06:T4 N
/N N
/N
/
/
/
28:1 L A10!NG LENSTH Pt/23 14/32 63 L AN0!NG R.Y= LENGTH
/
/
/
/
/
61 CTLG 085TACLE
/
/
/
/
/
62 NGT*ABOVE TMR
/
/
/
/
/
63 DIST FROM TrR
/
/
/
/
/
64 C N T P.LN OFFSCT
/
/
/
/
/
1-i t)) ARPY MGP PLE ASC ADVISC F33 IN ITCP B6 WHEN CPANGC5 0CCUR 70 TTCa$ PRCCCCC0 EY >
/aas r a naw r A*57 P
14 APCM RATIO 2f:1 AT CSPLCD THR 10 TRCC5.
4881 ACTVT MIRL 5/23 et*F=4 4 MIPL 16/32 - 123.8.
AF82 FRCC 122 85 AVBL ON PCC.
Alls -81 CTN: P!rATCRT !!PCs ON IN VCNTY OF AP*T.
ADdi-REZ.AS Ru)y GS ou t 6 F Ss ris L.t., 'al6a FWni"W/
Cep1rathl $5%f. T hr$./ To r34 08 A N O4L U M "
A U6 0
/09 /OLfNt
$d/Y C $
AN*
/4}kIkTk T ud e. cz a. 4 5 C 9 4. I A l
- 0 G.
p pf s. I 2 M b,,
Y
,rr__, _ re,C,:,,,
,.N,V..
,,3 LA,,
,.; F, ACC, NSP U an.- imw.,.............,....t.
~_
g
' -=_7c;; ;
'*T<..
... ~..
f
[' ~,gy--g7f$.
- z tr
\\
~
~
e k
kl ez o
v%::. "!,\\, t e -q.', b _
es
\\.
3=. p c~
x c.
=. ',
t s--
. '.. 4
=
a.
I
.=.,%.,,3 m..
I g
- ' " ~
E Qo 9,
J P 4..
n -
o~
a a
y
~
.... 7 5
J s --
a Ee I, ' " "o
,,0.'.,
E*
['Qt:) %
d.'*"**
6" Washoem
\\'...L,,,..
/,,
- j i{oQ { j.
F p'..pa..
h
'~
t' c
AinPORT L ATOVI N
w'
,e,a c...e
) Ji iL
.......T.
E
- .+
g
,y,,
y, N,
/r s.......
'l f
6 i
4 O
Ri et.t*
- 0**
Til 5
ei C
j'
/'o+D P
,3 a2 9
+
R3
.o*
'k 3
w.
A Al A
\\
si
.C#
l l l!
o O
- apAL$A
'{
N/
J j
l l
l ZION NUCLEAR P0HER STATION ANNUAL 10CFR50.59 REPORT 1988 NRC DOCKETS 50-295 AND 50-304 COMMONWEALTH EDISON COMPANY I
i 1102t(5) i
(.
I' 1
I' l
l TABLE OF CONTENTS 1.
Modifications II. Tests III. Experiments IV. Other Safety Evaluations 1102t(6)
d 1.
Modifications A.
Refueling 1 The unit two refueling outage that started in October 1988 ended in December 1988.
Fuel was loaded in 1988.
Unit one refueling outage started in February 1988 and ended in May 1988, fuel was loaded in 1988.
B.
Modifications Four reportable modifications were completed and verified to operate properly.
The modifications are:
1.
dqdification Description - M22-0-86-17 Provide raised center desk in Control Room.
This modification raised the center desk area approximately 1 foot and gives the Station Control Room Engineer clear view of both control boards and provides for more effective routing of personnel traffic in the Control Room. Spaces for computer terminals, files and table space were incorporated into the design.
This Modification satisfies DCRDR HED 0010, 0011, 0216 and 0298.
Safety Evaluation Summary This Modification is non-safety related, non-EO, but cabinets and raised floor supports are mounted seismically to the existing floor.
This Modification does not interact with any system that is safety related and does not involve any Tech Spec or FSAR issues.
2.
Modification Description - M22-0-87-11 Manual switches in gas analyzer cabinet.
This Modification permanently lifts the leads to solenoid valves on the sample lines to Unit 1 and 2 VCT's because the sample valve can be opened inadvertently by hitting adjacent buttons on the panel.
Safety Evaluation Summary The lifted leads make the system safer by preventing inadvertent release through sample valves of radioactive waste gas. VCT gas space sampling is not addressed in the Tech Spec's.
3.
Modification Description - M22-1-84-04 Modify Rx trip breakers per NRC Reg. and HOG recommendations.
This Modification does not alter the existing reactor protection, but adds the auto shunt trip capability.
The reactor trip breaker shunt coils were replaced with qualified coils.
1 1102t(7)
4 Safety Evaluation Summary This change adds extra protection features.
If more breaker cycles are required for testing, then it is possible that the breakers will have to be replaced more frequently.
- However, this should not impact breaker performance.
This change is being done compatibly with previous existing features.
4 Modification Description - M22-1-86-23 Eliminate points on by-pass and permissive.
This Modification satisfied NRC concerns related to DCRDR HED 172, 348, & 369; l
requiring simplification and reduction of Unneeded Annunciation on the bypass and permissive Annunciator Panel on the Unit 1 Control Board.
The remaining Annunciation on this Panel will be changed to the Dark Board Concept.
l Safetv Evaluation Summary This Modification only involves Annunciator alarms, which does not affect FSAR accidents nor Tech Spec basis margin of Safety.
II.
Tests i
The only testing conducted was done per Tech Spec requirements which involved Performance Testing and Surveillance Testing as required by Zion Station Technical Specifications.
III. Experiments There were no experiments conducted that involved a change in the Technical Specifications or unreviewed safety questions.
IV. Other Safety Evaluations:
A.
Temporary Alterations
- _BB-105
==
Description:==
BIT outlet valve leakage reroute to RCDT (to route potential charging system leakage past 2MOV-SI8801A and B to RCDT) l' Date installed:
12-11-88 Date removed: Still installed 50.59 Evaluation:
Tech Specs allow up to 10 gpm of identified leakage but this TA will not exceed that limit.
- ___88-106
==
Description:==
Provide high pressure seal for incore detector location D-10 Date installed:
12-08-88 Date removed: Still installed 50.59 Evaluation:
Tech Spec number of thimbles still available.
- _H8-107
==
Description:==
Disable BIT retirc low flow alarm, BIT high pressure alarm, and BIT low temperature alarm.
Date installed:
12-14-88 Date removed: Still installed 50.59 Evaluation:
Tech Spec change no longer mandated these alarms.
I 1102t(8)
v.
- _88-112
==
Description:==
CH pump screen a trips disabled to protect pumps from false trips due to ice conditions.
Date installed:
12-22-88 Date removed: Still installed 50.59 Evaluation: TA changes description of system in FSAR but does not effect plant' safety.
==
Description:==
Lifted. lead to defeat loss of AC power annunciator for Instrument Air while 2B 1A dryer is 005.
Date installed:
06-30-88 Date removed: 08-22-88 50.59 Evaluation:
Not a Tech Spec related alarm.
- _H:8046
==
Description:==
Bypass solenoid for SH-south pump area o
aircraft crash isolation damper to fail damper shut during fan maintenance.
Date instal' led:
08-05-88 Date removed: Still installed 50.59 Evaluation: Damper is failed in safeguards or fail safe position.
- B-8044
==
Description:==
Block OMOV-SH0003 open, U-1 and U-2 cross-tie, during overhaul of MOV operator.
Date installed:
07-13-88 Date removed: 08-02-88 50.59 Evaluation:
Isolation of cross-tie available from OM0V-SH0004 and OMOV-SH0003 is blocked in safeguard position.
- B-8042
==
Description:==
Bypass 1FT-522 high side sensing line because it is plugged.
Date installed:
06-03-88 Date removed: Still installed 50.59 Evaluation:
1FT-522 is still operable ~by providing high side sensing.
from calibration connection on 1LT-529.
- _2:a097
==
Description:==
TPF from Bus 232 to a portable load center Date installed:
02-06-88 Date removed: 01-30-89 50.59 Evaluation:
Bus 232 is not a safety related bus.
- _J-3.027
==
Description:==
TPF from MCC235-11 to EM shop Date installed:
07-08-88 Date removed: Still installed 50.59 Evaluation: MCC235-11 is not powered from an ESF bus.
==
Description:==
Lifted lead to permit IFH-FH2O to remain open on FH pump trip while 1FH-CD23C is DOS Date installed:
07-16-88 Date removed: 10-18-88 50.59 Evaluat',r: TA does not effect FH20's FSAR function to open during a low flow condi r 1.
1
==
Description:==
Lif ted lead to permit 1FCV-FH19 to remain l
open on FH pump trip while 1FCV-CD23C is DOS Date installed:
07-16-88 Date removed: 10-18-88 50.59 Evaluation: TA does not affect FH19's FSAR function to open during a low flow condition.
1102t(9)
A-
==
Description:==
_ Lifted lead to ensure IA low receiver pressure remains in effect while 2B air receiver is 00S for maintenance Date installed:
06-30-88 Date removed: 08-22-88 l
50.59 Evaluation:
Not a Tech spec related alarm function and alarm remains operable for other IA receivers.
- _J-8032
==
Description:==
TPF from MCC2354 to the Hunter Fabrication Shop Date installed:
08-01-88 Date removed: 02-03-89 50.59 Evaluation: MCC2354 is not powered from an ESF bus.
- _J-8029
==
Description:==
TPF from HCC2351 to Records Vault Lamenating Machine Date installed:
07-22 Date removed: 02-03-89 50.59 Evaluation: MCC2351 is not powered from an ESF bus.
- J-8012
==
Description:==
TPF from 2AP167 to operating management change room receptacles Date installed:
03-17-88 Date removed: Still installed 50.59 Evaluation:
2AP167 is not powered from an ESF bus.
- J-8013
==
Description:==
TPF from 2AP167 to operating management change room air conditioners Date i.nstalled:
03-17-88 Date removed: Still installed 50.59 Evaluation:
ZAP-167 is not powered from an ESF bus.
- J-8009
==
Description:==
TPF from RLC61 to operating management change room lighting Date installed:
._Ql-02-88 Date removed: Still installed 50.59 Evaluation:
RLC61 is not powered from an ESF bus.
- J-8011
==
Description:==
TPF from MCC1351B to 0LN096 to supply offices on 608' level Date installed:
02-05-88 Date removed: 02-03-89 50.59 Evaluation: MCC1351B is not powered from an ESF bus.
- _J-H039
==
Description:==
TPF from MCC2354 to Mechanical Maintenance Helding Room Date installed:
08-03-88 Date removed: 02-03-89 50.59 Evaluation: MCC2354 is not powered from an ESF bus.
- ,J-8038
==
Description:==
Heat trace for DG-2B aircraft crash isolation damper air actuator Date installed:
07-29-88 Date removed:_Still installed 50.59 Evaluation:
Enhances operability of damper without modifying or degrading system.
1102t(10)
4
- _J:3037
==
Description:==
Heat trace for DG-2A aircraft crash isolation l
damper air actuator
]
Date installed:
07-29-88 Date removed: Still installed 50.59 Evaluation:
Enhances operability of damper without modifying or f
degrading system.
- J-8033
==
Description:==
TPF from MCC2354 to North Trailer Date installed:
08-01-88 Date removed: 02-03-89 50.59 Evaluation:
MCC2354 is not powered from an ESF bus.
- J-8035
==
Description:==
Heat crace for DB-1R aircraft crash isolation damper air actuator lines.
Date installed:
07-29-88 Date removed 5f111 inftALLed 50.59 Evaluation:
Heat trace enhances damper operabil <. ' without modifying or degrading system.
- _2:3031
==
Description:==
TPF from MCC1356A to Hang room Date installed:
07-22-88 Date removed: 02-04-89 50.59 Evaluation: MCC1356A is not powered from an ESF bus.
- J-8030
==
Description:==
TPF from MCC1356B to ALARA office Date installed:
07-22-88 Date removed: 02-04-89 50.59 Evaluation: MCC1356B is not powered from an ESF bus.
- J-8028
==
Description:==
Jumper to permit annunciator for PZR spray low temperature to function for unisolated spray supply line Date installed:
07-01-88 Date removed: 07-25-88 50.59 Evaluation:
Ensures operability of annunciator for spray line not isolated.
- _l:30J7
==
Description:==
TPF to temporary snubber trailer from MCC1351B Date installed:
03-26-88 Date removed: 01-13-89 50.59 Evaluation: MCC1351B is not powered from an ESF bus.
- 88-005
==
Description:==
Block shut valves 2A0V-RV0002 and 2A0V-RV0004, containment purge containment isolation valves, during modification of the valve operators Date installed:
08-31-88 Date removed: 09-23-88 50.59 Evaluation:
Valves are blocked in their fail safe or safeguards position.
- J-8034
==
Description:==
Heat trace for DG-0 aircraft crash isolation damper air actuator lines Date installed: _02:22:88 Date removed: Still installed S0.59 Evaluation:
Heat trace enhances damper operability without modifying or degrading system.
- _l:3905
==
Description:==
TPF from 0LP107 to 617' GSEP office Date installed:
02-01-88 Date removed: Still installed 50.59 Evaluation: OLP107 is not powered from an ESF bus.
1102t(11)
4
,g
- J-8002
==
Description:==
TPF from 0LP107 to 617' GSEP office Date installed:
02-01-88 Date removed: Still installed 50.59 Evaluation: OLP107 is not powared from an ESF bus.
~
- J-8036
==
Description:==
Heat trace for DG-1B aircraft crash isolation damper air actuator lines Date installed:
07-29-88 Date removed: Still installed 50.59 Evaluation:
Heat trace enhances damper operability without modifying or degrading system.
i
- 88-036
==
Description:==
Temporary power feed from 2A control rod drive vent fan to supply 120V miscellaneous loads in U-2 containment Date installed:
10-24-88 Date removed: 12-7-88 50.59 Evaluation: CRDM vent fan is not required to be operational when unit is shutdown.
- _B8.-033
==
Description:==
Temporary power feed from 2C CRD booster fan motor to supply portable HEPA filter in U-2 containment Date installed:
10-24-88 Date removed: 12-7-88 50.59 Evaluation:
Fan is not required to be operational when unit is shutdown.
- 88-028
==
Description:==
Block open reheat stop valves to MSR to permit ventilating MSR's through upper manways.
Date installed:
10-12-88 Date removed: 12-20-88 50.59 Evaluation: Operability _of MSR's are not required in CSD.
- '88-0.10
==
Description:==
PZR spray line low temperature alarm jumpered to ensure alarm function is available for the spray supply line not isolated Date installed:
09-09-88 Date removed: 01-6-89 50.59 Evaluation:
TA ensures alarm function is available for spray supply line in operation.
- 88-044
==
Description:==
Line stop installed for the replacement of 2B RHR heat exchanger relief valve q
Date installed:
11-18-88 Date removed: 11-18-88
)
50.59 Evaluation:
Heat exchanger is not required to be operational in mode 5 l
or 6 with alternate RHR heat exchanger available.
j
- _8.8-043
==
Description:==
Line stop installed for the replacement of 2A j
RHR. heat exchanger relief valve Date installed:
11-10-88 Date removed: 11-10-88 50.59 Evaluation:
ricat exchanger is not required to be operational in mode 5 or 6 with alternate RHR heat exchanger available.
- ._B8-042
==
Description:==
Block open 2A0V-FP08, FP to containment, during deenergization of MCC2371 Date installed:
11-11-88 Date removed: 12-06-88 1
50.59 Evaluation: Valve is not required for containment isolation in modes 5 or 6.
1102t(12) l l
c.
- 88-041
==
Description:==
Block open 2IA01B, IA to U-2 containment, during deenergization of MCC2381B Date installed:
11-10-88 Date removed: 11-26-88 50.59 Evaluation:
Valve is not requir'd for containment isolation in modes 5 e
or 6.
- 88-040
==
Description:==
Block open-21A01A, IA to U-2 containment, during deenergization of MCC2371 Date installed:
11-10-88 Date removed: 11-26-88 50.59 Evaluation: Valve is.not required for containment isolation in modes 5 or 6.
'#_H8-049
==
Description:==
Line stop installed for replacement of relief valve 2CC9429 on spent fuel heat exchanger 2SF007 for testing Date installed:
11-22-88 Date removed: 11-11-88 50.59 Evaluation: Only one of two available spent fuel pit heat exchangers need to be in service.
- _E8-048
==
Description:==
Line stop installed for replacement of relief valve 2CC9432 on OC CC pump suction line for testing Date installed:
11-18-88 Date removed: 11-22-88 50.59 Evaluation: Alternate means of pump overpressure protection available so OC pump can remain in service.
- 88-047
==
Description:==
Line block installed for replacement of relief valve 2CC9421B on letdown heat exchanger 2VC003 for testing Date. installed:
11-17-88 Date removed: 11-17 50.59 Evaluation:
Letdown heat exchanger is not required to be operation in mode 5 or 6
- 88-046
==
Description:==
Line stop installed for replacement of relief valve 2CC9419 on boric acid evaporator condenser for testing 1
Date' installed:
11-21-88 Date removed: 11-21-88 i
50.59 Evaluation:
Boric acid evaporator condenser is not required to be operational in mode 5 or 6.
- 88-045
==
Description:==
Line stop installed for the replacement of the seal water heat exchanger relief valve for testing Date installed:
11-12-88 Date removed:_11-12-88 50.59 Evaluation:
Seal water heat exchanger is not required to be operational in mode 5 or 6.
- 88-056
==
Description:==
Block open service air containment isolation valves to provide servir e air for breathing air in U-2 containment Date installed:
10-25-88 Date removed: 11-22-88 50.59 Evaluation: Service air containment valves are not required to be operable in mode 5 or 6.
1102t(13)
a
- 88-054
==
Description:==
Remove temporary cover on fuel building roof penetration to permit pathway.for eddy current testing cables Date installed:
10-22-88 Date removed: 11-22-88 50.59 Evaluation:
Building is maintained at a pressure less than atmosphere to prevent release of radioactivity.
- 88-052
==
Description:==
OB north SH pump area' vent damper blocked shut during deenergization of MCC2382 Date installed:
11-13-88 Date removed:_11-18-88 50.59 Evaluation:
Damper is blocked in its fail safe or safeguard position.
- 88-051
==
Description:==
OA north Sw pump area vent damper blocked shut during deenergization of associated MCC Date installed:
11-30-88 Date removed: 12-06-88 50.59 Evaluation:
Damper is block in its fail safe or safeguard position.
- 88-050
==
Description:==
OC north SH pump area vent damper block shut during deenergization of MCC2392 Date installed:
11-05-88 Date removed: 11-11-88 50.59 Evaluation:
Damper is blocked in its fail safe or safeguard position.
- _AfL-068
==
Description:==
Line stop for removal of blank flange installed for reinstallation of 2CC9421A Date installed:
11-18-88 Date removed: 11-18-88 50.59 Evaluation:
Relief valve is on a seal water heat exchanger which is not required in mode 5 or 6.
- ._88-067
==
Description:==
Blank flange for replacement of 2CC9421A seal water heat exchanger relief valve Date installed:
11-12-88 Date removed: 11-18-88 50.59 Evaluation:
Seal water heat exchanger is not required to be operable in mode 5 or 6.
- 88-065
==
Description:==
Blank flange installed for replacement of 2CC9432 OC CC pump suction relief Date installed:
11-18-88 Date removed: 11-22-88 50.59 Evaluation: Alternate overpressure available from surge tank so pump remains operable.
i
- 88-064
==
Description:==
Line stop to permit removal of blank flange l
installed for removal of 2CC9432 OC CC pump suction relief
)
Date installed:
11-22-88 Date removed: 11-22-88 1
50.59 Evaluation: Alternate overpressure protection available from surge tank l
so pump can remain operable, j
l 4
- 88-061
==
Description:==
Block open containment sump valves and bypass containment sump pump interlock to permit operation of pump during ESF bus drop testing Date installed: _12-01-88 Date removed: 12-06-88 50.59 Evaluation:
Valves are not required to be operable in mode 5 or 6.
)
1102t(14) l C -- -
j
I 1,
- _B8-093
==
Description:==
Block shut 2MOV-FH0057, aux feedwater to 2D steam generator, to permit overhaul of valve motor operator Date installed:
11-26-88 Date removed: 11-30-88 i
50.59 Evaluation:
FSAR required number of AFH pumps are still available.
I i,
- 88-092
==
Description:==
Block open service air containment isolation valves to supply breathing sir during refueling outage -
Date installed:.
11-22-88 Date removed: 12-14-88 50.59 Evaluation:
Service air containment isolation valves are not required to be operable in mode 5 or 6.
- _BB-D34
==
Description:==
Block open containment sump valves and bypass containment sump pump interlock to permit operation of pumps during ESF bus drop testing
- Date installed:
11-9-88 Date removed: 11-19-88 50.59 Evaluation:
Valves are not required to be operational in modes 5 or 6.
- 88-070
==
Description:==
Blank flange relief line downstream of 2CC9429 to permit testing of valve subsequent to its replacement Date installed:
11-22-88 Date removed: 11-29-88 50.59 Evaluation:
Relief valve is on a spent fuel pit heat exchanger and only one of two is required to be operable.
- 88-069
==
Description:==
Block line upstream of 2CC9429 to permit testing of valve subsequent to its replacement Date installed:
11-29-88 Date removed: 11-29-88 50.59 Evaluation:
Relief valve is on a spent fuel pit' heat exchanger and only one of two is required to be operable.
- _BB-110
==
Description:==
Lifted lead on 28 FH pump latch permissive solenoid to permit maintenance on the FH pump control system Date installed:
12-15-88 Date removed: 12-20-88 50.59 Evaluation:
Sufficient FH pumps are available for service during 2B FH pump maintenance.
- 88-109
==
Description:==
Deenergize fuel shutoff solenoid for 2C CS diesel during preventive maintenance on diesel Date installed: _12-12-88 Date removed: 12-13-88 50.59 Evaluation:
Conta'.nment spray system not required to be operational in Mode 5.
- _B3-191
==
Description:==
Bypass U-2 reactor vessel level indication reference leg to permit determining location of blockage on the high pressure side of the level transmitter Date installed:
11-30-88 Date removed: 12-03-88 50.59 Evaluation:
Not a concern because refueling RVLI's still available to determine level.
1102t(15)
e l
.# 88-100
==
Description:==
Block open miniflow recirc valve, 2FCV-RT610..
to permit rebuilding of valve operator Date installed:
12-02-88 Date removed:_12-08-88 50.59 Evaluation:
Not a concern because block ensures a recirc path for 2A RHR. pump is available during valve maintenance.
- 88-097'
==
Description:==
Block open 21A01A, IA containment isolation L
valve, to ensure IA is available to U-2 containment during maintenance being.
performed-on Bus 247 Date installed:
11-30-88 Date removed: 12-06-88 50.59 Evaluation:
Not a concern because containment integrity is not. required in Mode 5 or 6.
- 88-078
==
Description:==
Block shut IMOV-SH0008, SH return MOV from ID REFC, to permit overhaul of valve motor operator Date installed:
11-11-88 Date removed: 11-20-88
'50.59 Evaluation:
Not a concern because the Tech Spec number of RCFC's are available for service during the valve maintenance.
- 88-060
==
Description:==
Disable the low header pressure autostart feature for CC pumps OC, 00, & OE to permit CC pump to sequence on via the safe shutdown times Date installed: _10-25-88 Date removed: 11-02-88 50.59 Evaluation: Autostart feature is not a FSAR related function and allowing the pumps to sequence via the safe shutdown times' permits the system to function as intended during a LOCA concurrent with blackout.
- _a8-021
==
Description:==
Block open OMOV-SH0012 and OMOV-SH0015 on CC "0" heat exchanger to permit overhaul of valve motor operators Date installed:
09-30-88 Date removed: 10-21-88 50.59 Evaluation: Not a concern because alternate isolation valves available and heat exchanger remains available for service.
l i
- 88-016
==
Description:==
Block shut OMOV-SH0005, U-2 supply to SH 4
booster pumps, to permit overhaul of valve motor operator Date installed:
09-16-88 Date removed: 09-23-88 50.59 Evaluation:
Not a concern because valve is block in safeguard position and an alternate SH supply to the FP system is available.
- 88-004
==
Description:==
Block shut OMOV-SH0006, U-1 supply to SH booster pumps, to permit overhaul of valve motor operator Date installed:
09-01-88 Dat6 removed: 09-08-88 50.59 Evaluation:
Not a concern because valve is block in safeguard position and an alternate SH supply to the FP system is available.
- 88-002
==
Description:==
Block open OMOV-SH0004, U-1 and U-2 SH cross-tie valve, to permit overhaul of valve motor operator Date installed:
08-24-88 Date removed: 08-31-88 50.59 Evaluation:
Not a concern because valve is block in safeguard position and anLalternate SH supply to the FP system is available.
1102t(16)
- fB-8014
==
Description:==
Block open 1FCV-HD178, containment sump containment isolation valve, to prevent closure during U-1 refueling outage Date installed:
03-04-88 Date removed: 04-03-88 50.59 Evaluation:
Containment integrity not required in Modes 5 or 6.
- _S:SQl3
==
Description:==
Block open 1FCV-HD17A, containment sump containment isolation valve, to prevent closure during U-1 refueling outage Date installed:
03-04-88 Date removed: 04-03-88 50.59 Evaluation: Containment integrity not required in Modes 5 or 6.
- _B-BD12
==
Description:==
Block open 1FCV-SA01A, service air containment isolation valve, to provide breathing during U-1 refueling outage Date installed:
03-04-88 Date removed: 04-03-88 50.59 Evaluation: Containment integrity not required in Modes 5 or 6.
- B-8011
==
Description:==
Block open 1FCV-SA01B, service air containment isolation valve, to provide breathing during U-1 refueling outage Date installed:
03-04-88 Date removed: 04-03-88 50.59 Evaluation: Containment integrity not required in Modes 5 or 6.
- B08010
==
Description:==
Defeat U-1 containment personnel hatch interlock to allow personnel and equipment access during U-1 outage Date installed:
03-04-88 Date removed: 04-23-88 50.59 Evaluation: Containment integriti not required in Modes 5 or 6.
- _S:HQ2D
==
Description:==
Block 1A RCP seal injection to protect RCP seal during IVSH test Date installed:
03-25-88 Date removed:_Di-06-88 50.59 Evaluation:
RCPs are required in Modes 5 or 6 with two operable RHR trains.
- B-8018~
==
Description:==
Defeat U-1 escape hatch interlock to accommodate U-1 outage work j
Date installed:
03-25-88 Date removed: 04-06-88 50.59-Evaluation: Containment integrity not required in Modes 5 or 6.
- _Er&017
==
Description:==
Block open IIA-018, instrument air containment isolation valve, to prevent valve from closing during U-1 outage I
work Date installed:
03-04-88 Date removed: 04-11:B_8 50.59 Evaluation:
Containment integrity not required in Mcies 5 or 6.
)
- _E:BQ16
==
Description:==
Block open IIA-01A, instrument air containment isolation valve, to prevent valve from closing during U-1 outage work Date installed:
03-04-88 Date removed: 04-13-88 50.59 Evaluation: Containment integrity not required in Modes 5 or 6.
i 1102t(17)
e L
- ,c
- _B-BQ15
Description:
Block open 1FCV-FP08, fire protection containment isolation valve, to prevent valve from closing during U-1 outage work.
Date installed:
03-04 Date removed: 04-22-88 50.59 Evaluation:
Containment integrity not required in Modes 5 or 6.
y
- B-8026
==
Description:==
Block open 1FCV-HD178, containment sump containment isolation valve, to preclude inadvertent closure during refuel
- outage Date installed:
04-04-88 Date removed: 04-22-88 50.59 Evaluation:
Containment isolation valve is not required to be operable in Modes 5 or 6.
- B-8025
==
Description:==
Block open 1FCV-HD17A, containment sump containment isolation valve, to preclude inadvertent closure during refuel outage Date installed:
04-04-88 Date removed: 04-22-88 50.59 Evaluation: Containment isolation valve is not required to be operable in Modes 5 or 6.
- B-8023
==
Description:==
Block 1D RCP seal injection to protect RCP seal during IVSH test Date installed:
03-25-88 Date removed: 04-06-88 50.59 Evaluation:
RCP's'are not required in Mo. des 5 or 6 with two operable RHR trains.
- B-8022
==
Description:==
Block 1C RCP seal injection to protect RCP seal during IVSH test Date installed:
03-25-88 Date removed: 04-06-88 50.59 Evaluation:
RCP's are not required in Modes 5 or 6 with two operable RHR trains.
- _B-HQ21
==
Description:==
Block 1B RCP seal injection to protect RCP seal during IVSH test Date installed:
03-25-88 Date removed: 04-06-88 50.59 Evaluation:
RCP': are not required in Modes 5 or 6 with two operable RHR trains.
- _B:BD31
==
Description:==
Block 1A RCP seal injection to protect RCP seal during IVSH test Date installed:
04-13-88 Date removed: 04-15-88 50.59 Evaluation:
RCP's are not required in Modes 5 or 6 with two operable RHR trains.
i
- _h dD30
==
Description:==
Block open containment ventilation purge valve 1A0V-RV0003 J
L Date installed:
04-04-88 Date removed: 04-14-88 50.59 Evaluation:
Containment integrity not required in refueling mode.
1102t(18)
- B-8029
==
Description:==
Block open containment ventilation purge valve 1A0V-RV0001 Date installed: _Q4:04-88 Date removed:_D.4-14-88 50.59 Evaluation: Containment integrity not required in refueling mode.
- _H E028
==
Description:==
Block open 1FCV-SA01B, service air containment isolation valve, to supply breathing air during U-1 outage Date installed:
04-04-88 Date removed: 04-22-88
'50.59 Evaluation: Containment isolation valve is not required to be operable in Modes 5 or 6.
- B-BR27
Description:
Block open'1FCV-SA01A,' service air containment isolation valve, to supply breathing air during U-1 outage Date installed:
04-03:H8 Date removed: 04-22-88 50.59 Evaluation:
Containment isolation valve is not required to be operable in Modes 5 or-6.
- _H:B036
==
Description:==
Block open containment hatch during U-1 outage Date installed:
04-23-88 Date removed: 04-24-88 50.59 Evaluation: Containment integrity not required in refueling mode.
- _H:BQ34
==
Description:==
Block la RCP seal injection to protect RCP seal during seal injection line flush Date installed:
04-13-28 Date removed: 04-15-88 50.59 Evaluation:
RCP's are not required in Modes 5 or 6 with two operable RHR trains.
- _E EQ35
==
Description:==
Block 1FCV-MS85 (18 main steam bypass valve) shut during diaphragm replacement on valve operator Date installed:
04-19-88 Date removed: 04-19-88 50.59 Evaluation: Valve operability not required while in Modes 5 or 6.
- B-8033
==
Description:==
Block 1C RCP seal injection to protect RCP seal during seal injection line flush Date installed:
04-13-88 Date removed: 04-15-88 1
50.59 Evaluation:
RCP's are not required in Modes 5 or 6 with two operable RHR trains.
- B-8032
==
Description:==
Block 1B RCP seal injection to protect RCP seal during seal injection line flush Date installed:
04-13-88 Date removed: 04-15-88 50.59 Evaluation:
RCP's are not required in Modes 5 or 6 with two operable RHR trains.
- _B-8009
==
Description:==
Block open IMOV-SHOO 17, SH to DG's, to permit limitorque inspection Date installed:
02-28-88 Date removed: 03-02-88 50.59 Evaluation:
Provides continued cooling to DG's, alternate isolation valves available.
1102t(19)
e 0, 36
- _E-8008-
==
Description:==
Block open IPCV-456, PZR steam space relief to PRT, to allow performance o.f ILRT-Date installed:
02-29-88 Date removed: 03-05-88 i
50 59 Evaluation: Valve will be blocked open to ensure overpressure i
protection available.
l
- .J-8007
==
Description:==
Block open IPCV-455C, PZR steam spare relief-to PRT, to allow performance of ILRT
. 02-29-88 Date removed: 03-05-88 Date installed:
50.59 Evaluation: Valve will be blocked open to ensure overpressure i
protection available.
j
- ,B-8006
==
Description:==
Defeat interlock on.U-1 containment personnel hatch to permit personnel & equipment access Date installed:
02-26-88 Date removed: 03-02-88
-l 50.59 Evaluation: Containment integrity not required in Mode 5 or 6.
- _3-E003
==
Description:==
Block open 1H0V-SH0106, Aux FH service water crosstie,-to permit maintenance on valve motor operator Date installed:
02-10-88 Date removed: 02-16-88 50.59 Evaluation: Valve is blocked in safeguard position, alternate isolation available.
- B-8001
==
Description:==
Block open 1MOV-SH0107, Aux F service water crosstie, to permit maintenance on valve motor operator Date installed:
01-19-88 Date removed: 01-22-88 50.59 Evaluation: Valve is blocked in safeguard position, alternate isolation available.
- J-8010
==
Description:==
TPF from 1AP167 to a Turbine Building contractor Date installed:
03-05-88 Date removed: 05-25-88 50.59 Evaluation: 1AP167 is not powered from an ESF-bus.
- _l-8Sj 9
==
Description:==
Jumper limit switch relays for containment ventilation purge valves to permit purge Date installed:
02-05-88 Date removed:_.0_4-20-88 i
50.59 Evaluation: Operability of purge valve not required in Modes 5 or 6.
I
- B-80_18
==
Description:==
Jumper limit switch relays for containment 4
ventilation purge valves to permit purge Date installed:
04-04-88 Date removed: 04-05-88 50.59 Evaluation: Operability of purge valve not required in Modes 5 or 6.
i
- _3-8014
==
Description:==
Defeat interlocks associated with valve IMOV-SI8804B to permit testing of valve without securing RHR Date installed:
03-20-88 Date removed: 03-30-88 l
50.59 Evaluation:
SI system operability not required in Modes 5 or 6.
1102t(20)
\\
i
- J-8011
==
Description:==
TPF from CRD vent booster fan 1C to a portable l
HEPA unit Date installed:
03-09-88 Date removed: 03-31-88 50.59 Evaluation:
TPF is from a non ESF source.
- _1-8008
==
Description:==
TPF from MCC13418 to ILRT instrumentation Date installed:
02-26-88 Date removed: 04-11-88 50.59 Evaluation:
MCC1341B is not powered from an ESF bus.
==
Description:==
Defeat OC aux building supply fan low temperature trip while glycol system is 00S Date installed:
01-28-88 Date removed:_Q5-03_-88 50.59 Evaluation:
Adequate temperature indication available to monitor aux building temperature.
==
Description:==
Defeat OB aux building supply fan low temperature trip while glycol system is 005 Date installed:
01-21-88 Date removed: 05-06-88 50.59 Evaluation:
Adequate temperature indication available to monitor aux building temperature.
==
Description:==
Defeat OA aux building supply fan low temperature trip while glycol system is 00S Date installed:
01-21-88 Date removed: 05-06-88 i
l 50.59 Evaluation:
Adequate temperature indication available to monitor aux building temperature, i
i l