_ _ _ _ _ _ _ _ _ _ _ _ _ _
.~
- e.
MM Log # TXX-89370 Fi1e # 10110 C
C 903.11
' # ***'R'***'
1UELECTRIC June 12, 1989 WlHiem J. CahiH. Jr.
Executive Vice President U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D. C.
20555
SUBJECT:
COMANCHE PEAK STEAM ELECTRIC STATION (CPSES)
DOCKET NOS. 50-445 AND 50-446 CONSUMABLE MATERIALS REPLACEMENT PROGRAM SDAR:
CP-87-47 (SUPPLEMENTAL REPORT)
Gentlemen:
On February 9,1988, TU Electric letter logged TXX-88215 provided notification that the deficiency involving the consumable material replacement program was deemed reportable under the provisions of 10CFR50.55(e). The latest report on this issue, logged TXX-89178, was submitted April 14, 1989. This report is submitted to update the schedule for completion of the corrective actions.
The remaining corrective actions for Unit I have been rescheduled to be completed prior to Unit 1 fuel load.
As previously stated in TXX-89178, corrective actions for Unit 2 will be completed prior to Unit 2 fuel load.
Sincerely, William J. Cahill, Jr.
1 By:
D. R. Woodlan Docket Licensing Manager WJH/vid c - Mr. R. D. Martin, Region IV Resident Inspectors, CPSES (3) 8906190225 890612
{DR ADOCK0500g5 f