ML20244D260
| ML20244D260 | |
| Person / Time | |
|---|---|
| Site: | 07109184 |
| Issue date: | 04/17/1989 |
| From: | Macdonald C NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS) |
| To: | |
| Shared Package | |
| ML20244D255 | List: |
| References | |
| NUDOCS 8904210243 | |
| Download: ML20244D260 (4) | |
Text
__________________.- ------------ -- ------------ ---'
- p_
I U.S. NUCLEAR RECULATORY COMMISSION f i l "oS " " -
CERTIFICATE OF COMPLIANCE y
i to crR 78 FOR RADIOACTIVE MATERIALS PACKAGES y
i
- c. PACKAGE IDENilFICAYlON NUMBEM d.PAGE t UMBER
- e. TOTAL NUMBER PAGES g
1 1 a CERME NUMBER tt REISION NUMBER USA /9184/B(U) 1 2
l l
l 1
I l
certificate is issued to certify that the packaging and contents described in item 5 below, meets the applicable safety standards set forth in Title 10. Code i
a 1
i of redermi neguistions, part ti.-eackaging and Transportation of radioactive heatenai.-
I et This certificate does not reheve the consignor from comphance witn any requirernent of the reguistions of ine u.s. Department of Transportation or otner I
appucabie reputatory agencies, including the government of any country through or into wnich tne package will be transported.
p I
I I
i l
3 ms comi cAgis;ssuEo ON TuE exses or A sArrTV ANALYSTS, REPORT T,Hg GN OR CA l
I i
l Nuclear Packaging, Inc.
Nuclear Packaging, Inc. consolidated application I
1010 South 336th Street dated March 31, 1989, as supplemented.
f i
Federal Way, WA 98003 l
l
,c.LeiddEI(7.1-9184 I
te is condated upon fulfdkng ttie e nts of 10 CFR Part 71, as apphcab6e r the conditions specrfied below.
l e
n x
o
M; <.
l I
(a) Packaging q
l g
I (1) Model.No.: ' PAS l-
.A i
fM i
I m
3 s
(2) Description
\\
/
(*)
i m z,i
.s m u
'he packaging consists.of a primary < containment vessel,(20.5" 0D x 23.4" l
l i
I OH) enclose.inside as. secondary _ containment-vessel and radiation shield l
l (32.5" OD x 39.0" 0H)..The 15 millileter-water sample %is contained I
within a undefined sample cask.rAddition' ally, <four iodine collection I
~
l I
i cartridges and four offgas vials are maintained inside the foam i
shoring above' the sample cask. ! Loose vermiculite surrounds the l
1 perimeter of the sample. cask;toiabsorb the water sample should leakage i
I occur CCompletely surrounding ~ the' secondary contat.nment vessel and l
l radiation shield is'a foam filled steel encased overpack (48.0" OD x I
66.0" 0H) which providesHmpact thermal protection'.,
I i
Q, y J.~
, f3 '
p i
i The primary / containment vessel which is constru'cted of 304 stainless steel i
i varying in thickness form 3/4" to 1.25" is pr6vided with double Viton i
j 0-ring seals and a' sealed test porp bqtween the seals for leak testing.
l The assembly is secured;with)eightp/8" '16 UNC x 8" long screws.
l l
i I
The secondary containment vessel and radiation shield provides 0.75" p
I i
wo thick steel and 5,1" thick lead shielding in the radial direction, 2.0" i
I D.5N thick steel and 5.1" thick lead shielding on the bottom, and 3.5" thick i
l c,3 steel and 4.8" thick lead shielding on the top.
The lid is securud with il eight, 1.0"-8 UNC x 3.0 long bolts. The lid is sealed with two Viton I
e i
I i
0-rings with a sealed test port between the seals for leak testing.
l cw l
i eu The overoack provides about 7.25" thick foam on the sides and about 13" i
i No I
30 on the top and bcttom. The two halves of the overpack are held together l
l Q
by eight, 3/4"-10 UNC x 1.5" long bolts. A Neoprene gasket prevents I
i g
rain water from entering the overpack.
[
l wa.o g
l The weight of the package including a maximum sample cask weight of p
I 1,375 pounds, is about 12,800 pounds.
p I
(I I
i we__-----------------------------
h U'"'""'
" ' ' t"'
'^
conomous toontinued)
[
,- Page 2 - Certificate No. 9184 - Revision No. 2 - Docket No. 71-9184 l
l 5.
(3) Drawings The package is constructed in accordance with Nuclear Packaging, Inc.
[
Drawing No. X-20-218D, Sheets 1 and 2, Rev. C.
(
(b) Contents
{
(1) Type and form of material
(
l (i) Radioactive material n fermtof quid or gaseous samples in sample L
casks, cart id s[an. 'viali. C' (if) Byproduct; and' activation materials as olfds and process solids or resins,Neither dewatered, solid, or solidifjed in :;econdary containers.
' (%
r.sv
,f (2) Maximum quintity'of material per package
- 9 L
.,[
.,, /.
[
D
'N b
/
50 Ci(of mixed'fishion and activation products,'15 milliliters of
(
liquid','one sample casksor secondary container and four cartridges and
[
n four als.
,5
(,
- 6.
In addition to the requirements'of Subpa.ttlofA0 CFR Part 71, each package prior L
b to first use must meet (the acceptan'ce tests and, criteria specified.in Section 8.1, must be maintained in accordance with Section 8.~1,'and. prepared for shipment l
in accordance 'with Section '7.0 of/.the application.'
$T 7,Mi6yiyF'J o
7.
The package authorized by;this certificate:isMereby approved for use under the I
general license provisions of_10-CFR1%71.12. C 1 l
B
, 1., 3
(,
p 8.
Expiration date: 'Ap,ril 30,1994 ' h,~{/ i. 0 ' 6
(.
l l a
- ,q,
v j ';
REFERENCES
,f,d il 7
g e
Nuclear Packaging, Inc. consolidated app}icat, ion dated March 31, 1989.
l
(
- Supplement, dated April 7, 1989. O
)R C i
y p1 l
x 1
r~
FOR THE U.S. NUCLEAR REGULATORY COMMISSION l
Ii 1
Of4 b
i
- E Charles E. Mac o.ald, Chief a
/
Transportation Branch I
i Division of Safeguards N
l and Transportation, NMSS l
~
APR 171989 e
i Date:
l l
l l
l l
1 l
l l
i
x------=--,--.
[.
4'C UNITED STATES
,7
(;
- [
g
. NUCLEAR REGULATORY COMMISSION
'l WASHINGTON, D. C. 20555 l
(,. '., k, *.. [
j.
?
Transportation Branch Approval Record Model No. PAS-1 Docket No. 71-9184 Revision No. 2 By the consolidated application dated March 31, 1989, as supplemented Nuclear Packaging, Inc., requested renewal of Certificate of Compliance No. 9$84.
No changes to the package were requested.
The certificate of compliance has been renewed for a five year term which expires April 30, 1994.
?
Sf4 o
,62-Charles E. MacD d, Chief Transportation Branch Division of Safeguards and Transportation, NMSS Date:
Model No. PAS.1 Packaging Docket No. 71-9184 Addressees: w/encls Ltr dtd:
BOSTON EDIS0N COMPANY NIAGARA M0 HAWK POWER CORP.
L ATTN: 'Mr. Ralph G. Bird ATTN: Mr. Channing Gerber 800 Boylston Street P.O. Box 32-1 Boston, MA 02199 Lycoming, NY 13093 CAROLINA POWER & LIGHT COMPANY NUCLEAR PACKAGING INC.
ATTN: Mr. B. H. Webster ATTN: Mr. Steve A. Porter Route 1 Box 327 1010 South 336th Street New Hill, NC 27562 Federal Way, WA 98003 DETROIT EDISON NEW YORK POWEk AUTHORITY ATTN: Mr. B. Ralph Sylvia ATTN: Mr. R. J. Converse 6400 North Dixie Hwy P. O. Box 41 Newport, MI. 48166 Lycoming, NY 13093 FLORIDA POWER & LIGHT CO.
PENNSYLVANIA POWER & LIGHT ATTN: Mr. C. M. Wethy ATTN: Mr. Harold W. Keiser P. O. Box 128 2 North 9th Street Ft. Pierce, FL 33450 Allentown, PA 18101 FLORIDA POWER CORPORATION PHILADELPHIA ELECTRIC COMPANY ATTN: Mr. Rolf C. Widell ATTN: Mr. W. J. Kna P.O. Box 8699 (S7-1)pp P. O. Box 14042 St. Petersburg, FL 33733 Philadelphia, PA 19101 GEORGIA POWER COMPANY PUBLIC SERVICE ELECTRIC & GAS C0.
ATTN: Mr. H. C. Nix ATTN: Mr. L. K. Miller Route #1, P. O. Box 278 P.O. Box 236 Baxley, GA 31513 Hancocks Bridge, NJ 08038 GPU NUCLEAR CORPORATION TENNESSEE VALLEY AUTHORITY ATTN: Mr. Thomas Snider ATTN: Mr. R. L. Gridley P.O. Box 388 SN 157B Lookout Place Forked River, NJ 08731 Chattanooga, TN 37401 IOWA ELECTRIC, LIGHT & POWER COMPANY ATTN: Mr. Herb Giorgio 3277 Daec Road l
Palo, IA 52324 4
1 l-l