Application for Amend to License DPR-57 Changing Tech Specs to Allow Temporary Extension of 24-h Limiting Condition for Operation of Drywell Inerting to 72-h
ML20244B845
Person / Time
Site: Hatch 
Issue date: 02/08/1982
From: Widner W
GEORGIA POWER CO.
To:
Office of Nuclear Reactor Regulation
Shared Package
ML20236H997 List:
References
TAC-54378, TAC-54379, NUDOCS 8202160488
Download: ML20244B845 (2)


Text

.r n

q; fb]

[j'h3.f h ?fhh*k,.',

.l jg;., _

~

.Il

^^

JGeg a Powe, Cornpany -

d M ?..A*hpJ (333 Pra?none Avenue (

y.

aw 2

~

JWi wania' Georps 30308,.

'y; y i Tetepnone 404 526g025 ?

F yr l

n J

' ; Masng Adoress, L

N

,, &> J V hg~ ;po,u Otsc, gy s$as.

a b

-f b $

i Aranta Georga 30302 p1 y

Georgia PowerL 4

E 2 Wi A. Widner February 8, ?l982 >

  1. * * *'" #*C" " " '"

d by, ci; f V,cs Presiaenf and General Manager k

f~~

' F0554 and Hycio Generahon u) ' 6 4

7

.e m

Qj P

LRECEWED

. FEB161982* 5 a

Director;of tbclear Reactor Regulation

U. 5., Nuclear Pegulatory Commission nr a mrrm m :a
Washington, D. C.

20555/

    • QN.

S

.c j

. NRC DOCKET.30-321 Id l

(

.g "J

-OPERATING LICENSE DPR-57

]

7.

EDWIN I. HATCH NUCLEAR PLANT UNIT l-IMMEDIATE' RELIEF FOR DRYWELL.INERTING-TECHNICAL SPECIFICATION h

-)

y~

Gentlemen-

, a

'1 Pursuanti to 10 CFR -50.90, as required by ~10 CFR 50.59(c), Georgia Power ;

i

. Company proposes 1 an amendment to the. Unit 1 Technical' Specifications

'l 1

(Appendix"A to the~ Operating ~ License).

Technical Specification 3.7. A.S.b - requires "withinithe 124-hour period :

/ subsequent to ' placing the reactor in the RUN mode following a' shutdown, the j

containment atmosphere ~ oxygen concentration shcIl be reduced to'less than 40 1

byJvolume andLmaintained in this' condition".

However, during the startup.of February 7; L1982, Lit became apparent thatL there was ~an insufficient amount-

i Lof' liquid nitrogen ' available to meetH this' 24-hour JLCO.

Additionally, j

resupplies ?are not available until after the 'LCO expires.'. We hereby request-1 a-one time extension :of the 24-hour-LCO to 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> beginning at 3 'p.m'.

EST n,

on February 7, 1982.

Minimum levels '(2000 gallons) of nitrogen are being h,,

mainta'ined to preserve operability of the Containment Atmosphere Dilution i

L(CAD). system per Technical Specification 3.7.A.6.b.

L Safety Evaluation'- Drywell Inerting b

The basis for a 24-hour requirement on attaining a 4 percent oxygen

1. <

~ concentration following. entry into the RUN mooe is to minimize the i

possibility of. hydrogen combustion.following a loss-of-coolant accident.

The 24-hour period was established, as stated in the bases for specification 3.7_. A.5,. as being suf ficient to perform necessary drywell inspections and establish-the required oxygen concentration.

The control is administrative and supplements the CAD system.

j i

3, i

p The CAD system provides the basis for assuring containment integrity

]

y

~

post LOCA.

Due. to the license date for Unit 1, the CAD system was installed l

to Lmeet. the then applicable regulations addressing. hydrogen evolution.

In I

[X

.Q order to meet the currently applicable interim final rule, capability to q

q install portable hydrogen recombiners is being engineered, and, therefore, l

h/ g M*.7 orgia. Power.Comoany is in compliance with the regulations.

! pl l

bb

%'d B20208 PDR ADOCK 05000321 I b 0

[

WP PCR.

= -.

a

W2, LJ ;MMW+WFWWM+PPP, 7"

" w + w ' ~ m W 5 I

I l

+eg ll 9Y 1

y y

g$

ry -

m y s

m,,

i y y g.

m

..p ;

y[g.g m ; ",

p',<'

l : n' ' ' '

.'-,",b,

,7.

,gf t

q t.

-N Y '{

d i s y-F

's

. 4. 7. t

1..
  1. n u

+

t at J4%GeorgisPo> wsr '

M'"

,v i

1

%yf 17 '

s !

g7e 5 M.

4 v..~.

m,

v~-

N JDirect$dof/ Nuclear. Reactor. Regulation,1 o

+

d@n... A 5

774 iUnS.Aiclear Regulatory Commission' >

F m,%. ym:,7,, < Washingtonf DC C.020535 ;

f:[

'JFebr0aryg,(1982f f,

,9 w

a e

N M R g agq Two

\\ ;

?

w$$W%

N

.n u

, ;.,.. w

%$e; ("g g4 Because3the (24-hourt limit X is h an l administrative ? control, m as ? opposed j to' l'

(providing "a /safetyffunction,duced 'bylallowing a'. : longer. period 'of time; margins of safety,f asi efine d

d~ dl hi

? Specifications,Jareinotfre to?

W 4%^

,,:completeidrywell;..'inerting-TheT safety marginbis ';providedj by7thei CAD; '

i a.c M

o+ ;

system.

, %p '

  • Addit.ionally, l due [tof plarb factars,.:' af maximumithe'rmal power flevel* of.-

4

,x y

k@

4Mlesshth'an'[ 50 f percent? will 'be reached.duriiig ithe reque'sted periddi.of(" ?,Y

[

f C

A l

i

. Lextension. JWef estimate ithat :inithe expected ; rod pattern, marginst to Ethe l,,

i V:MAPLHCR limitMshouldLapproach 50 : percent,Jproviding i additionalFconservatism W. '

,f

,%y 1totthe analysis? accident' conditions.

s,-

y-g<

%,,,, 1 Extension 'ofithe drywell'inerting LCO Jalso necessitates anJe'xtenAion/of-..' y' ', y m

the: LCO} for TechnicalL Specificatiori; 3.7. A'.7. (1) dDrywell-SuppressionlChamber m

^

nr, ;, %

-Dif ferential. Pressurei t for. a.' like! time ' period.' Re' quired differential-M y

s.;

pressurecannotbefestablisheduntil'inertingis-complete.D 7

3 s

s y 3 m

, g4 pni i jThis(submittai Jis; for immediate relief.: AL formal submittal,fincluding m *'

determination ^of amendment class,Lwill. follow.

o e

<..3 2 W, 1 W.E A. Widner ustates f that heJis Vicei President of...GeorgialPower Company cand,

?

Jis l authorized Jto? execute this; cath Lon; behalf of ' Georgia Po.wer L Company,5 and -

4 M

thatt to' the "bestiof his knowledge ' andL belief theJ facts set forth'in this '

'IB 1 M 11etter are true.,

a t

GEORGIA; POWER COMPANY-

}

S n.

m,

, /

' 'l By:

d 'a [,-

F N. 9

(

W. A. Widner r

"8c._

Sworni o and subscribed.before me this 8th day of February,1982.

D; 4

/ /

Notary Public, Georgia, State at Large

-Q My Commission E.xpires Sept. 20,1983 Q '/

gg 1

W f

Notary Public e

M m.

'RES/mb?

y y

E 9

x'c :

M. Manry u

R. F. Rogers, III

~

J.:P. O'Reilly (Region II - NRC) q; '

y

.h 1

g L

J 1

'O

i [.'

I k N,

.I {l i fl ' ' ' '

,f l