ML20239A384

From kanterella
Jump to navigation Jump to search
Forwards Radial Peaking Factor Limit Rept for Cycle 6,in Accordance W/Tech Spec Paragraph 6.9.1.11.Elevation Dependent Peaking Factor Vs Core Height Graph for Cycle 6 Also Encl in Support of Rept
ML20239A384
Person / Time
Site: Farley Southern Nuclear icon.png
Issue date: 09/15/1987
From: Mcdonald R
ALABAMA POWER CO.
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
NUDOCS 8709170300
Download: ML20239A384 (3)


Text

_---__- --

~

4:

a Alabama Power Company '

600 NorFs 38th Street

' Post Offi 3 Box 2641.

j Birmingham, Alabama 352914400 '

Telephone 205 250-1835.

. LM%e";%ioent Abbm hu 1

tre southern electncsystem

-10CFRSO.4

~I September 15, 1987 Docket No. 50-364

]

. V. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington,.D. C. 20555 i

Gentlemen:

Joseph M. Farley Nuclear Plant - Unit 2 Radial Peaking Factor 1.imit Report' Enclosed is the Radial Peaking Factor Limit Report for Cycle 6 of Unit 2.

This report 'is provided in accordance with Paragraph 6.9.1.11 of the Unit 2 Technical Specifications. Also enclosed is a copy of the elevation dependent peaking factor versus core height graph for ' Cycle 6 of Unit 2 which is.being submitted in support of the subject report.

If you have' any questions, please advise.

Respectfully subm tted,

/

p L.

W

~

R. P. Mcdonald

. RPM / JAR: dst-D-T.S.7 Enclosures

.cc:.Mr. L. B. Long Dr. J. N. Grace Mr. E. A. Reeves Mr. W. H. Bradford h

DOC 4

ENCLOSURE FARLEY UNIT 2 CYCLE 6 RADIAL PEAKING FACTOR LIMIT REPORT l

This Radial Peaking Factor Limit Report is provided in accordance with Paragraph 6.9.1.11 of the Joseph M. Farley Unit 2 Technical Specifications.

1 The F limits for RATED THERMAL POWER within specified core planes for Cycle k shall be:

x 1.

FpTP less than or equal to 1.77 for all core planes containing Bank "D

control rods, 2.

For all unrodded core planes:

P F[y less than or equal to 1.77 up to core elevations of 6.9 ft.

F!y less than or equal to 1.71 for core elevations above 6.9 ft.

TP These F v(z) limits are used to confirm that the heat flux hot x

channel Tactor F (z) will be limited to the Technical Specification q

values of:

F (z).< _2.31 [K(z)] for P > 0.5 and, q

7 F (z) $ 4,62 [M(z)] for P 1 0.5 q

assuming the most limiting axial power distributions expected to result from the insertion and removal of Control Banks C and D during operation, including the accompanying variations in the axial xenon and power distributions as described in the " Power Distribution Control and Load Following Procedures," WCAP-8385, September 1974.

Therefore, these F limits provide assurance that the initial xy conditions assumed in the LOCA analysis are met and the ECCS acceptance criterion limit of 2200 F for peak clad temperature is not exceeded.

t

i-i ENCLOSURE 2.4 ll

!ll l

ll ll 1llli l l 1.l l ll lll l

'll II ll

}

ii l ii i

ii i iiiit i 11llll lli il II l

3 l i l i l l' 411!

I!lli I

h tilli lilli l

m IIIIII I f l+1 IiiiI

+-

1 Ii 1h lIIil ll 2.2 I!

III l '1 1 t *l+1+11 if I I I I I i+1 d i I I I It I h I

il

)

I l

Ill lill ll l i l

  • I'l l

'Iillit l l ll l

ll 1

I

+

+

IIi iii l

I II I

Ili el !

1 I

l i

I

.I Ill Ill I

i I

11 I

lil ll It' l

2, 11 11 111lll lllllll lllll11 Ill 11 lI11llll 14 I

il 11 lilllll Illil I

ill il li ti l

s i

I ll 11ll111 I

I Ill I

il l

J!,,,

I I

I I

I 1111lll ll l

l

.Ill 1.

11 l

+

l' 1

l 1

11 ll

=-

I 11 I

s, 4

I a

,1 I

g i.,

l i

i i I

a I

I I

I I

i g

l 4

I I

I I

I I'

11 I

l l

Rl FXY LIMITS Il

.I II LP TO 6.9 FT.

1,77 l

lll IllI Il I I I l I, 11.

I FGOVE 6.9 FT.

1.71 lll{l l l

jl l

}l lilllil lillll lilllll lillll!

Illilll I l i l l l ll

.!!Illli il11i

!!II111 Illlll1 ilii11!

iIItIlill iII I

.IIilI iilillI ll 11I illlIti l 11 I I l l]

til i

111lll1 Ililili il lit litilli litilitt

'O 2

4 6

8 10 12 CORE HEIGHT (FEET)

I MAXIMUM F XP VERSUS CORE HEIGHT O

REL DURING NORMAL OPERATION

-