Docket No.
WM-064 James Anderson, Project Engineer Uranium Hill Tailings Project Office U.S. Department of Energy Albuquerque Operations Office P.O. Box 5400 Albuquerque, New Mexico 87115
Dear Jim:
Enclosed for your information is a brief summary of the meeting held in our office on August 19, 1987, in regards to the Lakeview UMTRA Project.
Attending from DOE was Richard Sena, accompanied by representatives of the TAC and RAC, Felix Miera of the State of Oregon, URF0 staff and our consultant Dr. Steven Abt of Colorado State University.
If you or your staff have any questions or comments, please call me at FTS 776-2805.
Sincerely, Edward F. Hawkins, Chief Licensing Branch 1 Uranium Recovery Field Office Region IV
Enclosure:
As stated cc:
Felix Miera Steven Abt 8709090400 G70902 PDR WASTE WM-64 PDR OFC : URF0 NAME : EHawkins/lv:
DATE :87/08/31
.)
~_
e as UNITED STATES p
\\
NUCLEAR REGULATORY COMMISSION D
REsson av URANtUM MECOVERY RELD OFMCE DENVER.
DO 80225 N
AUG 2 81987 URFO:TTO Docket No. WM-64 MEMORANDUM FOR:
Docket File No. WM-64 FROM:
Thomas T. Olsen, Project Manager Licensing Branch 1 Uranium Recovery Field Office, Region IV L
SUBJECT:
MEETING ON DESIGN CONSIDERATIONS DATE:
August 19, 1987 PARTICIPANTS:
NRC, DOE, MK-E, Weston, Jacobs Engineering and Oregon DOE 7
A meeting was held on Wednesday, August 19, 1987, to discuss design considerations for the Lakeview UMTRA Project.
Themajortopicsof 6
discussion were seepage drain design, riprap characteristics and sources,.and soil property specification, specifically Plastic Index (PI), for the radon barrier.
After much discussion, NRC determined that the PI requirement should b
remain as it was originally presented in the Remedial Action Inspection
-Plan (RAIP).
The basis for this determination was that a minimus PI is 4
needed to assure that the material conforms to the properties assumed I
when the radon barrier was designed. Without a minimum PI, 10 in this case, the barrier may be subject to forces that would destroy its integrity.
In addition, the DOE's contractor (MK-E) indicated that very little of the stockpiled material (2 percent or less) would not meet the PI requirement.
Accordingly, there appeared to be no valid reason for allowing 20 percent of the PI tests to fail.
Additionally, a new design for the seep drain was submitted by MK-E.
The design reportedly addresses all URF0 concerns.
DOE is to submit these revisions by transmittal letter, l
l l
/ --
)
,r )
Y so b
D l Qi [ L ' j (,;
' v ': ('
s A
L_ _- ____ -
Y
t t
7 AUG 2 81987 2-A discussion addressing riprap (bedding material) centered around the fact that the test data showed' poor quality rock.
The rock in question exhibits very poor absorption qualities.
00E and its contractors are going to evaluate the data further before proposing its use, or another alternative thereto.
The 00E will evaluate the above-mentioned problems and decide on what course of action to take to address URF0 concerns on design criteria.
$d Thomas T. Olsen, Project Manager Licensing Branch 1 Uranium Recovery Field Office Re ion IV Approved by:
Afm s
Edw'ard'F. HdwkinsMhief Liccasing Branch I w